Cause
At least one property of the data for a protected main function / main terminal that you have placed as a part with defined function templates (device) has been changed retrospectively (e.g. the Technical characteristics property). This type of change to a protected main function / main terminal at parts data that have already been selected is not permitted.
The complete terminal function is checked for a distributed displayed main terminal. In the process data that was entered at the individual terminals of the same terminal function is summarized.
Solution
- Note the property that was output in the message.
- Use the Go to functionalities to locate the main function / main terminal in the project.
- Open the properties for the protected main function / main terminal and compare the data for the property specified with the data for the corresponding property for the selected part.
- If the data differs, undo the retrospective modification to the protected main function / main terminal, or select a different part that has suitable parts data.
- If required, start a new check run.