This functionality is only available for certain module packages. Info / Copyright

P028032: The subordinate segments do not match the subordinate segment templates

Cause

It is possible with segment templates to create nested structures with planning objects, PCT loops, PCT loop functions etc. as a template and to reference them.

A subordinate segment in contrast to the segment template was deleted within such a nestled structure. Or a subordinate segment template was removed or added in the segment template without the segments being subsequently updated.

Solution

  1. First locate the affected segment in the pre-planning navigator using the Synchronize selection function offered by the popup menu in the Message management dialog.

    The respective segment is marked in the pre-planning navigator.
  2. To correct the substructure of an individual segment, select the popup menu item Reset to segment template for the segment selected in the pre-planning navigator.
    To correct all segments or a segment template, select the popup menu item Update segments for the segment template selected in segment template navigator.

    In both cases the structure in the pre-planning navigator is modified accordingly after the correction.
  3. If required, start a new check run.

Note:

Note that after the menu item Reset to segment template has been selected, other data of the segment is also reset, for example properties.