This functionality is only available for certain module packages. Info / Copyright

P501031: The general function definition '<x>' entered at the part should not be used at the part

Cause

In the parts database to be checked a part was found where a "general" function definition is entered. The general function definitions are intended to be used in projects if the exact parts are not yet clear when the project configuration is carried out. Only the exact function definitions should be entered in the parts management.

Note:

This message is only output for terminals.

Solution

  1. In the message management dialog mark the line with the message and select the Properties popup menu item.

    The Parts management dialog is opened, the respective part is already marked in it.
  2. Bring the Function templates tab to the front.
  3. In the Device selection (function templates) table click the entry in the Function definition column that contains the general function definition and click [...].
  4. Select an exact function definition from the Function definitions dialog that is opened.
  5. Close the parts management, save the modified data, and carry out a parts synchronization.
  6. Then start a new check run.