f01 |
list |
Part |
of the part stored in the project. |
No |
No |
f01 |
Parts list |
Part placement |
Properties of the part placement. If there are several for a part, the properties of the different are combined. |
Yes |
No |
f01 |
Parts list |
Part reference |
Properties of the part that can be changed at the device, and calculated properties. |
No |
No |
f01 |
Parts list |
Part reference manufacturer |
Properties of the manufacturer that are stated at the part reference (i.e., at the device) and that can be modified. |
No |
No |
f01 |
Parts list |
Part reference supplier |
Properties of the supplier that are stated at the part reference (i.e., at the device) and that can be modified. |
No |
No |
f01 |
Parts list |
Device |
Properties of the device that the part is assigned to. |
No |
No |
f01 |
Parts list |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f01 |
Parts list |
Mounting panel |
Properties of the mounting panel. |
Yes |
No |
f01 |
Parts list |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f01 |
Parts list |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f01 |
Parts list |
Pre-planning segment |
Properties of the segment that the part is assigned to. |
Yes |
No |
f01 |
Parts list |
Pre-planning segment |
Properties of the segment that the part is assigned to. |
Yes |
No |
f02 |
Summarized parts list |
Part |
Properties of the part stored in the project. |
No |
No |
f02 |
Summarized parts list |
Part placement |
Properties of the part placement. If there are several part placements for a part, the properties of the different representation types are combined. |
Yes |
No |
f02 |
Summarized parts list |
Part reference |
Properties of the part that can be changed at the device, and calculated properties. |
No |
No |
f02 |
Summarized parts list |
Part reference manufacturer |
Properties of the manufacturer that are stated at the part reference (i.e., at the device) and that can be modified. |
No |
No |
f02 |
Summarized parts list |
Part reference supplier |
Properties of the supplier that are stated at the part reference (i.e., at the device) and that can be modified. |
No |
No |
f02 |
Summarized parts list |
Device |
Properties of the device that the part is assigned to. |
No |
No |
f02 |
Summarized parts list |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f02 |
Summarized parts list |
Mounting panel |
Properties of the mounting panel. |
Yes |
No |
f02 |
Summarized parts list |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f02 |
Summarized parts list |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f02 |
Summarized parts list |
Pre-planning segment |
Properties of the segment that the part is assigned to. |
Yes |
No |
f02 |
Summarized parts list |
Pre-planning segment |
Properties of the segment that the part is assigned to. |
Yes |
No |
f03 |
list |
Connected PLC connection point |
Properties of the PLC connection point that is connected to the nth function of the device. |
Yes |
No |
f03 |
Device tag list |
Part |
Properties of the nth part entered at the device. |
Yes |
No |
f03 |
Device tag list |
Part reference |
Properties of the nth part entered at the device, that can be edited at the device. |
Yes |
No |
f03 |
Device tag list |
Device tag |
Structure identifiers, components of the device tag. |
No |
No |
f03 |
Device tag list |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f03 |
Device tag list |
Function |
Properties of the nth function of the device. |
Yes |
No |
f03 |
Device tag list |
Device group (further ) |
Properties of the nth function of the device group. Without an index value, all functions of the device group are output, except for the currently reported-on function. |
Yes |
No |
f03 |
Device tag list |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f03 |
Device tag list |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f03 |
Device tag list |
Pre-planning segment |
Properties of the nth segment that is assigned to the device. |
Yes |
No |
f03 |
Device tag list |
Pre-planning segment |
Properties of the nth segment that is assigned to the device. |
Yes |
No |
f04 |
documentation |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f04 |
Forms documentation |
Form |
Properties of the form. |
No |
No |
f05 |
Device-connection diagram |
Connected PLC connection point |
Properties of the PLC connection point that is connected to the device connection point. |
No |
No |
f05 |
Device-connection diagram |
Connection point, external |
Properties of the nth external connection point of the device. |
No |
No |
f05 |
Device-connection diagram |
Connection point, internal |
Properties of the nth internal connection point of the device. |
No |
No |
f05 |
Device-connection diagram |
Part |
Properties of the nth part entered at the device. |
Yes |
Yes |
f05 |
Device-connection diagram |
Part reference |
Properties of the nth part entered at the device, that can be edited at the device. |
Yes |
Yes |
f05 |
Device-connection diagram |
Device |
Properties of the device including the device tag. |
No |
Yes |
f05 |
Device-connection diagram |
Function |
Properties of the function belonging to the connection point. |
No |
No |
f05 |
Device-connection diagram |
Cable, external 'level (1-3)' |
Properties of the externally connected cable at the nth level. |
Yes |
No |
f05 |
Device-connection diagram |
Cable, internal 'level (1-3)' |
Properties of the internally connected cable at the nth level. |
Yes |
No |
f05 |
Device-connection diagram |
Last external target |
Properties of the last externally connected function found during . |
No |
No |
f05 |
Device-connection diagram |
Last internal target |
Properties of the last internally connected function found during target tracking. |
No |
No |
f05 |
Device-connection diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
Yes |
f05 |
Device-connection diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
Yes |
f05 |
Device-connection diagram |
Connection, external 'level (1-3)' |
Properties of the externally connected connection at the nth level. |
Yes |
No |
f05 |
Device-connection diagram |
Connection, internal 'level (1-3)' |
Properties of the internally connected connection at the nth level. |
Yes |
No |
f05 |
Device-connection diagram |
Pre-planning segment |
Properties of the segment that is assigned to the device. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f05 |
Device-connection diagram |
Pre-planning segment |
Properties of the segment that is assigned to the device. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f05 |
Device-connection diagram |
Target, external, connection point 'level (1-3)' |
Properties of the connection point of the externally connected function at the nth level. |
Yes |
No |
f05 |
Device-connection diagram |
Target, external, counter-connection 'level (1-3)' |
Properties of the continuing connection point of the externally connected function at the nth level. |
Yes |
No |
f05 |
Device-connection diagram |
Target, external 'level (1-3)' |
Properties of the externally connected function at the nth level. |
Yes |
No |
f05 |
Device-connection diagram |
Target, internal, connection point 'level (1-3)' |
Properties of the connection point of the internally connected function at the nth level. |
Yes |
No |
f05 |
Device-connection diagram |
Target, internal, counter-connection 'level (1-3)' |
Properties of the continuing connection point of the internally connected function at the nth level. |
Yes |
No |
f05 |
Device-connection diagram |
Target, internal 'level (1-3)' |
Properties of the internally connected function at the nth level. |
Yes |
No |
f06 |
Table of contents |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f06 |
Table of contents |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f06 |
Table of contents |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f06 |
Table of contents |
Project |
Properties of the project. |
No |
No |
f06 |
Table of contents |
Page |
Properties of the page. |
No |
No |
f06 |
Table of contents |
Pre-planning segment |
Properties of the segment that the page is assigned to. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f06 |
Table of contents |
Pre-planning segment |
Properties of the segment that the page is assigned to. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f07 |
Cable-connection diagram |
Cable |
Properties of the cable. |
No |
Yes |
f07 |
Cable-connection diagram |
Cable, external 'level (1-3)' |
Properties of the externally connected cable at the nth level. |
Yes |
No |
f07 |
Cable-connection diagram |
Cable, internal 'level (1-3)' |
Properties of the internally connected cable at the nth level. |
Yes |
No |
f07 |
Cable-connection diagram |
Cable part |
Properties of the nth part entered at the cable having the part assignments '' and ''. |
Yes |
Yes |
f07 |
Cable-connection diagram |
Cable part (assignment: source) |
Properties of the nth part entered at the cable having the part assignment 'Part source'. |
Yes |
Yes |
f07 |
Cable-connection diagram |
Cable part (assignment: target) |
Properties of the nth part entered at the cable having the part assignment 'Part target'. |
Yes |
Yes |
f07 |
Cable-connection diagram |
Cable part reference |
Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories', that are editable at the cable. |
Yes |
Yes |
f07 |
Cable-connection diagram |
Cable part reference (assignment: source) |
Properties of the nth part entered at the cable having the part assignment 'Part source', that are editable at the cable. |
Yes |
Yes |
f07 |
Cable-connection diagram |
Cable part reference (assignment: target) |
Properties of the nth part entered at the cable having the part assignment 'Part target', that are editable at the cable. |
Yes |
Yes |
f07 |
Cable-connection diagram |
Cable connection |
Properties of the / contained in the cable. |
No |
No |
f07 |
Cable-connection diagram |
Last external target |
Properties of the last externally connected function found during target tracking. |
No |
No |
f07 |
Cable-connection diagram |
Last internal target |
Properties of the last internally connected function found during target tracking. |
No |
No |
f07 |
Cable-connection diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
Yes |
f07 |
Cable-connection diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
Yes |
f07 |
Cable-connection diagram |
Connection, external 'level (1-3)' |
Properties of the externally connected connection at the nth level. |
Yes |
No |
f07 |
Cable-connection diagram |
Connection, internal 'level (1-3)' |
Properties of the internally connected connection at the nth level. |
Yes |
No |
f07 |
Cable-connection diagram |
Pre-planning segment |
Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f07 |
Cable-connection diagram |
Pre-planning segment |
Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f07 |
Cable-connection diagram |
Target, external, connection point 'level (1-3)' |
Properties of the connection point of the externally connected function at the nth level. |
Yes |
No |
f07 |
Cable-connection diagram |
Target, external, counter-connection 'level (1-3)' |
Properties of the continuing connection point of the externally connected function at the nth level. |
Yes |
No |
f07 |
Cable-connection diagram |
Target, external 'level (1-3)' |
Properties of the externally connected function at the nth level. |
Yes |
No |
f07 |
Cable-connection diagram |
Target, internal, connection point 'level (1-3)' |
Properties of the connection point of the internally connected function at the nth level. |
Yes |
No |
f07 |
Cable-connection diagram |
Target, internal, counter-connection 'level (1-3)' |
Properties of the continuing connection point of the internally connected function at the nth level. |
Yes |
No |
f07 |
Cable-connection diagram |
Target, internal 'level (1-3)' |
Properties of the internally connected function at the nth level. |
Yes |
No |
f08 |
Cable assignment diagram |
Part (source) |
Properties of the nth part entered at the source device. |
Yes |
No |
f08 |
Cable assignment diagram |
Part (target) |
Properties of the nth part entered at the target device. |
Yes |
No |
f08 |
Cable assignment diagram |
Part reference (source) |
Properties of the nth part entered at the source device, that can be edited at the device. |
Yes |
No |
f08 |
Cable assignment diagram |
Part reference (target) |
Properties of the nth part entered at the target device, that can be edited at the device. |
Yes |
No |
f08 |
Cable assignment diagram |
Device (source) |
Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
Yes |
No |
f08 |
Cable assignment diagram |
Device (target) |
Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
Yes |
No |
f08 |
Cable assignment diagram |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f08 |
Cable assignment diagram |
Cable |
Properties of the cable. |
No |
No |
f08 |
Cable assignment diagram |
Cable part |
Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories'. |
Yes |
No |
f08 |
Cable assignment diagram |
Cable part (assignment: source) |
Properties of the nth part entered at the cable having the part assignment 'Part source'. |
Yes |
No |
f08 |
Cable assignment diagram |
Cable part (assignment: target) |
Properties of the nth part entered at the cable having the part assignment 'Part target'. |
Yes |
No |
f08 |
Cable assignment diagram |
Cable part reference |
Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories', that are editable at the cable. |
Yes |
No |
f08 |
Cable assignment diagram |
Cable part reference (assignment: source) |
Properties of the nth part entered at the cable having the part assignment 'Part source', that are editable at the cable. |
Yes |
No |
f08 |
Cable assignment diagram |
Cable part reference (assignment: target) |
Properties of the nth part entered at the cable having the part assignment 'Part target', that are editable at the cable. |
Yes |
No |
f08 |
Cable assignment diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f08 |
Cable assignment diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f08 |
Cable assignment diagram |
Pre-planning segment |
Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f08 |
Cable assignment diagram |
Pre-planning segment |
Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f09 |
Cable diagram |
Part (source) |
Properties of the nth part entered at the source device. |
Yes |
No |
f09 |
Cable diagram |
Part (target) |
Properties of the nth part entered at the target device. |
Yes |
No |
f09 |
Cable diagram |
Part reference (source) |
Properties of the nth part entered at the source device, that can be edited at the device. |
Yes |
No |
f09 |
Cable diagram |
Part reference (target) |
Properties of the nth part entered at the target device, that can be edited at the device. |
Yes |
No |
f09 |
Cable diagram |
Device (source) |
Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
No |
No |
f09 |
Cable diagram |
Device (target) |
Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
No |
No |
f09 |
Cable diagram |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f09 |
Cable diagram |
Cable |
Properties of the cable. |
No |
Yes |
f09 |
Cable diagram |
Cable part |
Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories'. |
Yes |
Yes |
f09 |
Cable diagram |
Cable part (assignment: source) |
Properties of the nth part entered at the cable having the part assignment 'Part source'. |
Yes |
Yes |
f09 |
Cable diagram |
Cable part (assignment: target) |
Properties of the nth part entered at the cable having the part assignment 'Part target'. |
Yes |
Yes |
f09 |
Cable diagram |
Cable part reference |
Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories', that are editable at the cable. |
Yes |
Yes |
f09 |
Cable diagram |
Cable part reference (assignment: source) |
Properties of the nth part entered at the cable having the part assignment 'Part source', that are editable at the cable. |
Yes |
Yes |
f09 |
Cable diagram |
Cable part reference (assignment: target) |
Properties of the nth part entered at the cable having the part assignment 'Part target', that are editable at the cable. |
Yes |
Yes |
f09 |
Cable diagram |
Cable connection |
Properties of the conductors / connections contained in the cable. |
No |
No |
f09 |
Cable diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
Yes |
f09 |
Cable diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
Yes |
f09 |
Cable diagram |
Connection part |
Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories'. |
Yes |
No |
f09 |
Cable diagram |
Connection part (assignment: source) |
Properties of the nth part entered at the connection having the part assignment 'Part source'. |
Yes |
No |
f09 |
Cable diagram |
Connection part (assignment: target) |
Properties of the nth part entered at the connection having the part assignment 'Part target'. |
Yes |
No |
f09 |
Cable diagram |
Connection part reference |
Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories', that are editable at the connection. |
Yes |
No |
f09 |
Cable diagram |
Connection part reference (assignment: source) |
Properties of the nth part entered at the connection having the part assignment 'Part source', that are editable at the connection. |
Yes |
No |
f09 |
Cable diagram |
Connection part reference (assignment: target) |
Properties of the nth part entered at the connection having the part assignment 'Part target', that are editable at the connection. |
Yes |
No |
f09 |
Cable diagram |
Pre-planning segment |
Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f09 |
Cable diagram |
Pre-planning segment |
Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f10 |
Cable overview |
Part (source) |
Properties of the nth part entered at the source device. |
Yes |
No |
f10 |
Cable overview |
Part (target) |
Properties of the nth part entered at the target device. |
Yes |
No |
f10 |
Cable overview |
Part reference (source) |
Properties of the nth part entered at the source device, that can be edited at the device. |
Yes |
No |
f10 |
Cable overview |
Part reference (target) |
Properties of the nth part entered at the target device, that can be edited at the device. |
Yes |
No |
f10 |
Cable overview |
Device (source) |
Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
Yes |
No |
f10 |
Cable overview |
Device (target) |
Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
Yes |
No |
f10 |
Cable overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f10 |
Cable overview |
Cable |
Properties of the cable. |
No |
No |
f10 |
Cable overview |
Cable part |
Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories'. |
Yes |
No |
f10 |
Cable overview |
Cable part (assignment: source) |
Properties of the nth part entered at the cable having the part assignment 'Part source'. |
Yes |
No |
f10 |
Cable overview |
Cable part (assignment: target) |
Properties of the nth part entered at the cable having the part assignment 'Part target'. |
Yes |
No |
f10 |
Cable overview |
Cable part reference |
Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories', that are editable at the cable. |
Yes |
No |
f10 |
Cable overview |
Cable part reference (assignment: source) |
Properties of the nth part entered at the cable having the part assignment 'Part source', that are editable at the cable. |
Yes |
No |
f10 |
Cable overview |
Cable part reference (assignment: target) |
Properties of the nth part entered at the cable having the part assignment 'Part target', that are editable at the cable. |
Yes |
No |
f10 |
Cable overview |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f10 |
Cable overview |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f10 |
Cable overview |
Pre-planning segment |
Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f10 |
Cable overview |
Pre-planning segment |
Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f11 |
Terminal-connection diagram |
Connected PLC connection point |
Properties of the PLC connection point that is connected to the terminal. |
No |
No |
f11 |
Terminal-connection diagram |
Cable, external 'level (1-3)' |
Properties of the externally connected cable at the nth level. |
Yes |
No |
f11 |
Terminal-connection diagram |
Cable, internal 'level (1-3)' |
Properties of the internally connected cable at the nth level. |
Yes |
No |
f11 |
Terminal-connection diagram |
Terminal |
Properties of the terminal. |
No |
No |
f11 |
Terminal-connection diagram |
Terminal connection point external |
Properties of the external terminal connection point. The properties are only output when the 'Connection point-specific output' form property is activated. A row is generated for every pair of . Terminals with more than two connection points are automatically split across multiple rows. In addition, terminal connection points that are not connected are output. |
No |
No |
f11 |
Terminal-connection diagram |
Terminal connection point internal |
Properties of the internal terminal connection point. The properties are only output when the 'Connection point-specific output' form property is activated. A row is generated for every pair of connection points. Terminals with more than two connection points are automatically split across multiple rows. In addition, terminal connection points that are not connected are output. |
No |
No |
f11 |
Terminal-connection diagram |
Terminal parts |
Properties of the nth part entered at the terminal. |
Yes |
No |
f11 |
Terminal-connection diagram |
Terminal part reference |
Properties of the nth part entered at the terminal that can be edited at the terminal. |
Yes |
No |
f11 |
Terminal-connection diagram |
Terminal strip |
Properties of the terminal strip. |
No |
Yes |
f11 |
Terminal-connection diagram |
Terminal strip parts |
Properties of the nth part entered at the terminal strip. |
Yes |
Yes |
f11 |
Terminal-connection diagram |
Terminal strip part reference |
Properties of the nth part entered at the terminal strip that can be edited at the terminal strip. |
Yes |
Yes |
f11 |
Terminal-connection diagram |
Last external target |
Properties of the last externally connected function found during target tracking. |
No |
No |
f11 |
Terminal-connection diagram |
Last internal target |
Properties of the last internally connected function found during target tracking. |
No |
No |
f11 |
Terminal-connection diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
Yes |
f11 |
Terminal-connection diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
Yes |
f11 |
Terminal-connection diagram |
Connection, external 'level (1-3)' |
Properties of the externally connected connection at the nth level. |
Yes |
No |
f11 |
Terminal-connection diagram |
Connection, internal 'level (1-3)' |
Properties of the internally connected connection at the nth level. |
Yes |
No |
f11 |
Terminal-connection diagram |
Pre-planning segment |
Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f11 |
Terminal-connection diagram |
Pre-planning segment |
Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f11 |
Terminal-connection diagram |
Target, external, connection point 'level (1-3)' |
Properties of the connection point of the externally connected function at the nth level. |
Yes |
No |
f11 |
Terminal-connection diagram |
Target, external, counter-connection 'level (1-3)' |
Properties of the continuing connection point of the externally connected function at the nth level. |
Yes |
No |
f11 |
Terminal-connection diagram |
Target, external 'level (1-3)' |
Properties of the externally connected function at the nth level. |
Yes |
No |
f11 |
Terminal-connection diagram |
Target, internal, connection point 'level (1-3)' |
Properties of the connection point of the internally connected function at the nth level. |
Yes |
No |
f11 |
Terminal-connection diagram |
Target, internal, counter-connection 'level (1-3)' |
Properties of the continuing connection point of the internally connected function at the nth level. |
Yes |
No |
f11 |
Terminal-connection diagram |
Target, internal 'level (1-3)' |
Properties of the internally connected function at the nth level. |
Yes |
No |
f12 |
Terminal line-up diagram |
Terminal |
Properties of the terminal. |
No |
No |
f12 |
Terminal line-up diagram |
Terminal parts |
Properties of the nth part entered at the terminal. |
Yes |
No |
f12 |
Terminal line-up diagram |
Terminal parts by product subgroups |
Properties of all parts entered at the terminal, sorted by product subgroup. |
Yes |
No |
f12 |
Terminal line-up diagram |
Terminal part reference |
Properties of the nth part entered at the terminal that can be edited at the terminal. |
Yes |
No |
f12 |
Terminal line-up diagram |
Terminal part reference by product subgroups |
Properties of all parts that are entered at the terminal and can be changed at the terminal, are sorted by product subgroup. |
Yes |
No |
f12 |
Terminal line-up diagram |
Terminal strip |
Properties of the terminal strip. |
No |
Yes |
f12 |
Terminal line-up diagram |
Terminal strip parts |
Properties of the nth part entered at the terminal strip. |
Yes |
Yes |
f12 |
Terminal line-up diagram |
Terminal strip parts by product subgroups |
Properties of all parts entered at the terminal strip, sorted by product subgroup. |
Yes |
Yes |
f12 |
Terminal line-up diagram |
Terminal strip part reference |
Properties of the nth part entered at the terminal strip that can be edited at the terminal strip. |
Yes |
Yes |
f12 |
Terminal line-up diagram |
Terminal strip part reference by product subgroups |
Properties of all parts that are entered at the terminal strip and can be changed at the terminal strip, are sorted by product subgroup. |
Yes |
Yes |
f12 |
Terminal line-up diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
Yes |
f12 |
Terminal line-up diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
Yes |
f12 |
Terminal line-up diagram |
Pre-planning segment |
Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f12 |
Terminal line-up diagram |
Pre-planning segment |
Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f13 |
Terminal diagram |
Connected PLC connection point |
Properties of the PLC connection point that is connected to the terminal. |
No |
No |
f13 |
Terminal diagram |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f13 |
Terminal diagram |
Main terminal |
Properties of the main terminal. |
No |
No |
f13 |
Terminal diagram |
Main terminal part |
Properties of the nth part entered at the main terminal. |
Yes |
No |
f13 |
Terminal diagram |
Main terminal part reference |
Properties of the nth part entered at the main terminal that can be edited at the terminal. |
Yes |
No |
f13 |
Terminal diagram |
Cable chart data area external |
Properties of the nth externally connected connection for the data area of the cable chart. |
Yes |
No |
f13 |
Terminal diagram |
Cable chart data area internal |
Properties of the nth internally connected connection for the data area of the cable chart. |
Yes |
No |
f13 |
Terminal diagram |
Cable chart data area via connection point |
Properties of the nth connected connection for the data area of the cable chart, indexed by connection points. The index [n] indicates the connection point number of the terminal in the order in which the connection points are defined on the symbol. |
Yes |
No |
f13 |
Terminal diagram |
Cable chart data area via form position |
Properties of the nth connected connection for the data area of the cable chart, indexed by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the . |
Yes |
No |
f13 |
Terminal diagram |
Cable chart header |
Properties of the nth connected connection for the header of the cable chart. To be used when the header has the same direction as the data area. |
No |
Yes |
f13 |
Terminal diagram |
Cable chart header external |
Properties of the nth externally connected connection for the header of the cable chart. To be used when the header is rotated with regard to the data area. |
Yes |
Yes |
f13 |
Terminal diagram |
Cable chart header external: Counter target |
Displays all externally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the terminal strip via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons. The index is used to assign them to the placeholder element Cable chart data area external with the same index value. The different terminal targets are output using their index. |
Yes |
Yes |
f13 |
Terminal diagram |
Cable chart header internal |
Properties of the nth internally connected connection for the header of the cable chart. To be used when the header is rotated with regard to the data area. |
Yes |
Yes |
f13 |
Terminal diagram |
Cable chart header internal: Counter target |
Properties of the nth internally connected counter target of the conductor. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the terminal strip via the conductor. In most cases, all conductors of a cable are connected to the same counter target. |
Yes |
Yes |
f13 |
Terminal diagram |
Cable chart header via connection point |
Displays all internally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the terminal strip via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons. The index is used to assign them to the placeholder element Cable chart data area internal with the same index value. The different terminal targets are output using their index. |
Yes |
Yes |
f13 |
Terminal diagram |
Cable chart header via form position |
Displays all internally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the terminal strip via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons. The index is used to assign them to the placeholder element Cable chart data area internal with the same index value. The different terminal targets are output using their index. |
Yes |
Yes |
f13 |
Terminal diagram |
Cable chart header: Counter target |
Displays all connected counter targets of a cable for the header of the cable chart. The counter target is the device that is connected to the terminal strip via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons. |
No |
Yes |
f13 |
Terminal diagram |
Terminal |
Properties of the terminal. |
No |
No |
f13 |
Terminal diagram |
Terminal connection point external |
Properties of the external terminal connection point. The properties are only output when the 'Connection point-specific output' form property is activated. A row is generated for every pair of connection points. Terminals with more than two connection points are automatically split across multiple rows. In addition, terminal connection points that are not connected are output. |
No |
No |
f13 |
Terminal diagram |
Terminal connection point internal |
Properties of the internal terminal connection point. The properties are only output when the 'Connection point-specific output' form property is activated. A row is generated for every pair of connection points. Terminals with more than two connection points are automatically split across multiple rows. In addition, terminal connection points that are not connected are output. |
No |
No |
f13 |
Terminal diagram |
Terminal parts |
Properties of the nth part entered at the terminal. |
Yes |
No |
f13 |
Terminal diagram |
Terminal part reference |
Properties of the nth part entered at the terminal that can be edited at the terminal. |
Yes |
No |
f13 |
Terminal diagram |
Terminal strip |
Properties of the terminal strip. |
No |
Yes |
f13 |
Terminal diagram |
Terminal strip parts |
Properties of the nth part entered at the terminal strip. |
Yes |
Yes |
f13 |
Terminal diagram |
Terminal strip part reference |
Properties of the nth part entered at the terminal strip that can be edited at the terminal strip. |
Yes |
Yes |
f13 |
Terminal diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
Yes |
f13 |
Terminal diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
Yes |
f13 |
Terminal diagram |
Connection / cable external |
Properties of the cable of the nth externally connected connection. |
Yes |
No |
f13 |
Terminal diagram |
Connection / cable internal |
Properties of the cable of the nth internally connected connection. |
Yes |
No |
f13 |
Terminal diagram |
Connection / cable via connection point |
Properties of the cable of the connection connected to the nth terminal connection point. The index [n] indicates the connection point number of the terminal in the order in which the connection points are defined on the symbol. |
Yes |
No |
f13 |
Terminal diagram |
Connection / cable via form position |
Properties of the cable of the nth connected connection, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. |
Yes |
No |
f13 |
Terminal diagram |
Connection, external |
Properties of the nth externally connected connection. |
Yes |
No |
f13 |
Terminal diagram |
Connection, internal |
Properties of the nth internally connected connection. |
Yes |
No |
f13 |
Terminal diagram |
Connection via connection point |
Properties of the connection connected to the nth terminal connection point. The index [n] indicates the connection point number of the terminal in the order in which the connection points are defined on the symbol. |
Yes |
No |
f13 |
Terminal diagram |
Connection via form position |
Properties of the nth connected connection, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. |
Yes |
No |
f13 |
Terminal diagram |
Pre-planning segment |
Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f13 |
Terminal diagram |
Pre-planning segment |
Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f13 |
Terminal diagram |
Target external |
Properties of the nth externally connected function. |
Yes |
No |
f13 |
Terminal diagram |
Target internal |
Properties of the nth internally connected function. |
Yes |
No |
f13 |
Terminal diagram |
Target via connection point |
Properties of the function connected to the nth terminal connection point. The index [n] indicates the connection point number of the terminal in the order in which the connection points are defined on the symbol. |
Yes |
No |
f13 |
Terminal diagram |
Target via form position |
Properties of the nth connected function, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. |
Yes |
No |
f14 |
Terminal-strip overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f14 |
Terminal-strip overview |
Terminal strip |
Properties of the terminal strip. |
No |
No |
f14 |
Terminal-strip overview |
Terminal strip parts |
Properties of the nth part entered at the terminal strip. |
Yes |
No |
f14 |
Terminal-strip overview |
Terminal strip part reference |
Properties of the nth part entered at the terminal strip that can be edited at the terminal strip. |
Yes |
No |
f14 |
Terminal-strip overview |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f14 |
Terminal-strip overview |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f14 |
Terminal-strip overview |
Pre-planning segment |
Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f14 |
Terminal-strip overview |
Target external |
Properties (DT) of the externally connected function(s). All different external targets of the terminal strip are output. |
No |
No |
f14 |
Terminal-strip overview |
Target internal |
Properties (DT) of the internally connected function(s). All different internal targets of the terminal strip are output. |
No |
No |
f15 |
Plot frame documentation |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f15 |
Plot frame documentation |
Plot frame |
Properties of the plot frame. |
No |
No |
f16 |
Potential overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f16 |
Potential overview |
Potential |
Properties of the potential. |
No |
No |
f17 |
Revision overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f17 |
Revision overview |
Project |
contained in the revision. |
No |
No |
f17 |
Revision overview |
Page |
Page properties contained in the revision. |
No |
No |
f18 |
Enclosure legend |
3D model view |
Properties of the 3D model view. |
No |
Yes |
f18 |
Enclosure legend |
Part |
Properties of the part entered at a part placement. |
No |
No |
f18 |
Enclosure legend |
Part placement |
Properties of the part placement. |
No |
No |
f18 |
Enclosure legend |
Part reference |
Properties of the part that can be changed at the device, and calculated properties. |
No |
No |
f18 |
Enclosure legend |
Device |
Properties of the main function at which the part of part placement is entered. |
No |
No |
f18 |
Enclosure legend |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f18 |
Enclosure legend |
Mounting panel |
Properties of the mounting panel. |
No |
Yes |
f18 |
Enclosure legend |
Mounting panel part |
Properties of the nth part entered at the mounting panel. |
Yes |
Yes |
f18 |
Enclosure legend |
Mounting panel part reference |
Properties of the nth part entered at the mounting panel that can be edited at the mounting panel. |
Yes |
Yes |
f19 |
PLC diagram |
Connected sensor / actuator |
Properties of the sensor or actuator connected to the PLC connection point. |
No |
No |
f19 |
PLC diagram |
Part |
Properties of the nth part entered at the PLC card. |
Yes |
Yes |
f19 |
PLC diagram |
Part reference |
Properties of the nth part entered at the PLC card that can be edited at the PLC card. |
Yes |
Yes |
f19 |
PLC diagram |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f19 |
PLC diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f19 |
PLC diagram |
PCT loop (header) |
Properties of the associated PCT loop. To be used for the header area of the report. |
No |
Yes |
f19 |
PLC diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f19 |
PLC diagram |
PCT loop function (header) |
Properties of the associated PCT loop function. To be used for the header area of the report. |
No |
Yes |
f19 |
PLC diagram |
PLC connection point |
Properties of the PLC connection point. |
No |
No |
f19 |
PLC diagram |
PLC card |
Properties of the PLC card. |
No |
Yes |
f19 |
PLC diagram |
PLC card communication unit |
Properties of the nth communication unit of the PLC card. |
Yes |
Yes |
f19 |
PLC diagram |
Connection |
Properties of the connected connections. |
Yes |
No |
f19 |
PLC diagram |
Connection / cable |
Properties of the connected cable. |
Yes |
No |
f19 |
PLC diagram |
Pre-planning segment |
Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f19 |
PLC diagram |
Pre-planning segment |
Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f19 |
PLC diagram |
Pre-planning segment (header) |
Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. To be used for the header area of the report. |
Yes |
Yes |
f19 |
PLC diagram |
Pre-planning segment (header) |
Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. To be used for the header area of the report. |
Yes |
Yes |
f19 |
PLC diagram |
Target |
Properties of the function connected to the nth PLC connection point. |
Yes |
No |
f20 |
PLC card overview |
Connected sensor / actuator per connection point |
Properties of the sensor or actuator connected to the nth PLC connection point. |
Yes |
No |
f20 |
PLC card overview |
Part |
Properties of the nth part entered at the PLC card. |
Yes |
No |
f20 |
PLC card overview |
Part reference |
Properties of the nth part entered at the PLC card that can be edited at the PLC card. |
Yes |
No |
f20 |
PLC card overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f20 |
PLC card overview |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f20 |
PLC card overview |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f20 |
PLC card overview |
PLC connection point |
Properties of the PLC connection point. |
Yes |
No |
f20 |
PLC card overview |
PLC card |
Properties of the PLC card. |
No |
No |
f20 |
PLC card overview |
PLC card communication unit |
Properties of the nth communication unit of the PLC card. |
Yes |
No |
f20 |
PLC card overview |
Pre-planning segment |
Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f20 |
PLC card overview |
Pre-planning segment |
Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f21 |
Pin-connection diagram |
Connected PLC connection point |
Properties of the PLC connection point that is connected to the pin. |
No |
No |
f21 |
Pin-connection diagram |
Part |
Properties of the nth part entered at the plug. |
Yes |
Yes |
f21 |
Pin-connection diagram |
Part reference |
Properties of the nth part entered at the plug that can be edited at the plug. |
Yes |
Yes |
f21 |
Pin-connection diagram |
Cable, external 'level (1-3)' |
Properties of the externally connected cable at the nth level. |
Yes |
No |
f21 |
Pin-connection diagram |
Cable, internal 'level (1-3)' |
Properties of the internally connected cable at the nth level. |
Yes |
No |
f21 |
Pin-connection diagram |
Last external target |
Properties of the last externally connected function found during target tracking. |
No |
No |
f21 |
Pin-connection diagram |
Last internal target |
Properties of the last internally connected function found during target tracking. |
No |
No |
f21 |
Pin-connection diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
Yes |
f21 |
Pin-connection diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
Yes |
f21 |
Pin-connection diagram |
Plug |
Properties of the plug / plug definition. |
No |
Yes |
f21 |
Pin-connection diagram |
Plug counterpiece |
Properties of the plug counterpart if male and are represented separately, i.e. the properties of the assigned plug definition representing the receptacle or coupling. |
No |
Yes |
f21 |
Pin-connection diagram |
Pin |
Properties of the pin. |
No |
No |
f21 |
Pin-connection diagram |
Connection, external 'level (1-3)' |
Properties of the externally connected connection at the nth level. |
Yes |
No |
f21 |
Pin-connection diagram |
Connection, internal 'level (1-3)' |
Properties of the internally connected connection at the nth level. |
Yes |
No |
f21 |
Pin-connection diagram |
Pre-planning segment |
Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f21 |
Pin-connection diagram |
Pre-planning segment |
Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f21 |
Pin-connection diagram |
Target, external, connection point 'level (1-3)' |
Properties of the connection point of the externally connected function at the nth level. |
Yes |
No |
f21 |
Pin-connection diagram |
Target, external, counter-connection 'level (1-3)' |
Properties of the continuing connection point of the externally connected function at the nth level. |
Yes |
No |
f21 |
Pin-connection diagram |
Target, external 'level (1-3)' |
Properties of the externally connected function at the nth level. |
Yes |
No |
f21 |
Pin-connection diagram |
Target, internal, connection point 'level (1-3)' |
Properties of the connection point of the internally connected function at the nth level. |
Yes |
No |
f21 |
Pin-connection diagram |
Target, internal, counter-connection 'level (1-3)' |
Properties of the continuing connection point of the internally connected function at the nth level. |
Yes |
No |
f21 |
Pin-connection diagram |
Target, internal 'level (1-3)' |
Properties of the internally connected function at the nth level. |
Yes |
No |
f22 |
Plug diagram |
Connected PLC connection point |
Properties of the PLC connection point that is connected to the pin. |
No |
No |
f22 |
Plug diagram |
Female pin end |
Properties of the female pin end of the plug / plug definition. |
No |
Yes |
f22 |
Plug diagram |
Female pin end: Connected PLC connection point |
Properties of the PLC connection point that is connected to the pin on the female pin end. |
No |
No |
f22 |
Plug diagram |
Female pin end: Cable chart data area |
Properties of the nth connection connected at the female pin end for the data area of the cable chart. |
Yes |
No |
f22 |
Plug diagram |
Female pin end: Plug part |
Properties of the nth part entered on the female pin end of the plug. |
Yes |
Yes |
f22 |
Plug diagram |
Female pin end: Plug part reference |
Properties of the nth part entered at the female pin end of the plug and that can be edited at the plug. |
Yes |
Yes |
f22 |
Plug diagram |
Female pin end: Pin |
Properties of the pin at the female pin end. |
No |
No |
f22 |
Plug diagram |
Female pin end: Pin part |
Properties of the nth part entered at the pin. The pin is located on the female pin end of the plug. |
Yes |
No |
f22 |
Plug diagram |
Female pin end: Pin part reference |
Properties of the nth part entered at the pin, which can be edited at the pin. The pin is located on the female pin end of the plug. |
Yes |
No |
f22 |
Plug diagram |
Female pin end: Connection |
Properties of the nth connection connected on the female pin end. |
Yes |
No |
f22 |
Plug diagram |
Female pin end: Connection / cable |
Properties of the cable where the nth connection connected on the female pin end is located. |
Yes |
No |
f22 |
Plug diagram |
Female pin end: Target |
Properties of the connection point of the nth function connected on the female pin end. |
Yes |
No |
f22 |
Plug diagram |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f22 |
Plug diagram |
Cable chart data area external |
Properties of the nth externally connected connection for the data area of the cable chart. |
Yes |
No |
f22 |
Plug diagram |
Cable chart data area internal |
Properties of the nth internally connected connection for the data area of the cable chart. |
Yes |
No |
f22 |
Plug diagram |
Cable chart data area via form position |
Properties of the nth connected connection for the data area of the cable chart, indexed by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. |
Yes |
No |
f22 |
Plug diagram |
Cable chart header |
Properties of the nth connected connection for the header of the cable chart. To be used when the header has the same direction as the data area. |
No |
Yes |
f22 |
Plug diagram |
Cable chart header external |
Properties of the nth externally connected connection for the header of the cable chart. To be used when the header is rotated with regard to the data area. |
Yes |
Yes |
f22 |
Plug diagram |
Cable chart header external: Counter target |
Displays all externally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the plug via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons. The index is used to assign them to the placeholder element Cable chart data area external with the same index value. The different pin targets are output using their index. |
Yes |
Yes |
f22 |
Plug diagram |
Cable chart header internal |
Properties of the nth internally connected connection for the header of the cable chart. To be used when the header is rotated with regard to the data area. |
Yes |
Yes |
f22 |
Plug diagram |
Cable chart header internal: Counter target |
Displays all internally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the plug via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons. The index is used to assign them to the placeholder element Cable chart data area internal with the same index value. The different pin targets are output using their index. |
Yes |
Yes |
f22 |
Plug diagram |
Cable chart header via form position |
Properties of the nth connected connection for the header of the cable chart, indexed by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. To be used when the header is rotated with regard to the data area. |
Yes |
Yes |
f22 |
Plug diagram |
Cable chart header: Counter target |
Displays all connected counter targets of a cable for the header of the cable chart. The counter target is the device that is connected to the plug via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons. |
No |
Yes |
f22 |
Plug diagram |
PCT loop |
Properties of the associated PCT loop. |
No |
Yes |
f22 |
Plug diagram |
PCT loop function |
Properties of the associated PCT loop function. |
No |
Yes |
f22 |
Plug diagram |
Plug |
Properties of the plug / plug definition. |
No |
Yes |
f22 |
Plug diagram |
Plug part |
Properties of the nth part entered at the plug. |
Yes |
Yes |
f22 |
Plug diagram |
Plug part reference |
Properties of the nth part entered at the plug that can be edited at the plug. |
Yes |
Yes |
f22 |
Plug diagram |
Pin |
Properties of the pin. |
No |
No |
f22 |
Plug diagram |
Pin part |
Properties of the nth part entered at the pin. |
Yes |
No |
f22 |
Plug diagram |
Pin part reference |
Properties of the nth part entered at the pin, which can be edited at the pin. |
Yes |
No |
f22 |
Plug diagram |
Male pin end |
Properties of the nth part entered at the male pin end of the plug and that can be edited at the plug. |
No |
Yes |
f22 |
Plug diagram |
Male pin end: Connected PLC connection point |
Properties of the connection connected on the male pin end for the conductor table. |
No |
No |
f22 |
Plug diagram |
Male pin end: Cable chart data area |
Properties of the male pin end of the plug / plug definition. |
Yes |
No |
f22 |
Plug diagram |
Male pin end: Plug part |
Properties of the PLC connection point that is connected to the pin on the male pin end. |
Yes |
Yes |
f22 |
Plug diagram |
Male pin end: Plug part reference |
Properties of the nth part entered on the male pin end of the plug. |
Yes |
Yes |
f22 |
Plug diagram |
Male pin end: Pin |
Properties of the pin at the male pin end. |
No |
No |
f22 |
Plug diagram |
Male pin end: Pin part |
Properties of the nth part entered at the pin. The pin is located on the male pin end of the plug. |
Yes |
No |
f22 |
Plug diagram |
Male pin end: Pin part reference |
Properties of the nth part entered at the pin, which can be edited at the pin. The pin is located on the male pin end of the plug. |
Yes |
No |
f22 |
Plug diagram |
Male pin end: Connection |
Properties of the nth connection connected on the male pin end. |
Yes |
No |
f22 |
Plug diagram |
Male pin end: Connection / cable |
Properties of the cable where the nth connection connected on the male pin end is located. |
Yes |
No |
f22 |
Plug diagram |
Male pin end: Target |
Properties of the connection point of the nth function connected on the male pin end. |
Yes |
No |
f22 |
Plug diagram |
Connection / cable external |
Properties of the nth externally connected cable. |
Yes |
No |
f22 |
Plug diagram |
Connection / cable internal |
Properties of the nth internally connected cable. |
Yes |
No |
f22 |
Plug diagram |
Connection / cable via form position |
Properties of the cable of the nth connected connection, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. |
Yes |
No |
f22 |
Plug diagram |
Connection, external |
Properties of the nth externally connected connection. |
Yes |
No |
f22 |
Plug diagram |
Connection, internal |
Properties of the nth internally connected connection. |
Yes |
No |
f22 |
Plug diagram |
Connection via form position |
Properties of the nth connected connection, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. |
Yes |
No |
f22 |
Plug diagram |
Pre-planning segment |
Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f22 |
Plug diagram |
Pre-planning segment |
Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
Yes |
f22 |
Plug diagram |
Target external |
Properties of the nth externally connected function. |
Yes |
No |
f22 |
Plug diagram |
Target internal |
Properties of the nth internally connected function. |
Yes |
No |
f22 |
Plug diagram |
Target via form position |
Properties of the nth connected function, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. |
Yes |
No |
f23 |
Plug overview |
Part |
Properties of the nth part entered at the plug. |
Yes |
No |
f23 |
Plug overview |
Part reference |
Properties of the nth part entered at the plug that can be edited at the plug. |
Yes |
No |
f23 |
Plug overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f23 |
Plug overview |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f23 |
Plug overview |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f23 |
Plug overview |
Plug |
Properties of the plug / plug definition. |
No |
No |
f23 |
Plug overview |
Plug counterpiece |
Properties of the plug counterpart if male and female are represented separately, i.e. the properties of the assigned plug definition (connected plug or connected receptacle / coupling). |
No |
No |
f23 |
Plug overview |
Pre-planning segment |
Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f23 |
Plug overview |
Pre-planning segment |
Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f23 |
Plug overview |
Target external |
Properties (DT) of the externally connected function(s). All different external targets of the plug are output. |
No |
No |
f23 |
Plug overview |
Target internal |
Properties (DT) of the internally connected function(s). All different internal targets of the plug are output. |
No |
No |
f24 |
overview |
|
Properties of the structure identifier for the identifier block 'Higher-level function number'. All structure identifiers for the identifier block 'Higher-level function number' are output consecutively in one column. At the same time, the form can contain columns for additional such as '' or ''. |
No |
No |
f24 |
Structure identifier overview |
Installation site |
Properties of the structure identifier for the identifier block 'Installation site'. All structure identifiers for the identifier block 'Installation site' are output consecutively in one column. At the same time, the form can contain columns for additional identifier such as '' or 'Location designation'. |
No |
No |
f24 |
Structure identifier overview |
structure |
Properties of the structure identifier for the identifier block 'User-defined structure'. All structure identifiers for the identifier block 'User-defined structure' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Location designation'. |
No |
No |
f24 |
Structure identifier overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f24 |
Structure identifier overview |
|
Properties of the structure identifier for the identifier block 'Document type'. All structure identifiers for the identifier block 'Document type' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Location designation'. |
No |
No |
f24 |
Structure identifier overview |
|
Properties of the structure identifier for the identifier block 'Functional assignment'. All structure identifiers for the identifier block 'Functional assignment' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Location designation'. |
No |
No |
f24 |
Structure identifier overview |
Function designation |
Properties of the structure identifier for the 'Function designation' identifier block. All structure identifiers for the 'Function designation' identifier block are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Installation site' or 'Location designation'. |
No |
No |
f24 |
Structure identifier overview |
Location designation |
Properties of the structure identifier for the 'Location designation' identifier block. All structure identifiers for the identifier block 'Location designation' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Installation site'. |
No |
No |
f24 |
Structure identifier overview |
Product |
Properties of the structure identifier for the '' identifier block. All structure identifiers for the 'Product aspect' identifier block are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Location designation'. |
No |
No |
f24 |
Structure identifier overview |
Structure identifier |
Properties of the structure identifier. All structure identifiers in the project for all identifier blocks are output consecutively in one column, that is, all function , location designations, installation sites, etc. Within a form, the placeholder text 'Structure identifier' must not be used in combination with the for the structure identifiers of the individual identifier blocks, e.g., 'Function designation' or 'Location designation'. |
No |
No |
f25 |
Symbol overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f25 |
Symbol overview |
Symbol |
Properties of the symbol. |
No |
No |
f25 |
Symbol overview |
Symbol library |
Properties of the symbol library. |
No |
Yes |
f25 |
Symbol overview |
Variants (all variants) |
Special properties of all , or one of the symbol variants A to I (depending on the placeholder element selected). |
No |
No |
f27 |
Connection List |
3D part placement (source) |
Connection point properties of the 3D part placement, which represent the source of the connection. |
No |
No |
f27 |
Connection List |
3D part placement (target) |
Connection point properties of the 3D part placement, which represent the target of the connection. |
No |
No |
f27 |
Connection List |
Device (source) |
Properties of the source device. For connections, the graphically first DT is always the source. |
No |
No |
f27 |
Connection List |
Device (target) |
Properties of the target device. For connections, the graphically first DT is always the source. |
No |
No |
f27 |
Connection List |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f27 |
Connection List |
Cable |
Properties of the cable to which the connection is assigned. |
No |
No |
f27 |
Connection List |
Wire harness |
Properties of the wire harness to which the connection is assigned. |
No |
No |
f27 |
Connection List |
Wire harness part |
Properties of the first part entered at the wire harness. This is the part that represents the wire harness. |
No |
No |
f27 |
Connection List |
Wire harness part reference |
Properties of the first part entered at the wire harness, that can be edited at the wire harness. |
No |
No |
f27 |
Connection List |
Connection |
Properties of the connection. |
No |
No |
f27 |
Connection List |
Connection part |
Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories'. |
Yes |
No |
f27 |
Connection List |
Connection part (assignment: source) |
Properties of the nth part entered at the connection having the part assignment 'Part source'. |
Yes |
No |
f27 |
Connection List |
Connection part (assignment: target) |
Properties of the nth part entered at the connection having the part assignment 'Part target'. |
Yes |
No |
f27 |
Connection List |
Connection part reference |
Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories', that are editable at the connection. |
Yes |
No |
f27 |
Connection List |
Connection part reference (assignment: source) |
Properties of the nth part entered at the connection having the part assignment 'Part source', that are editable at the connection. |
Yes |
No |
f27 |
Connection List |
Connection part reference (assignment: target) |
Properties of the nth part entered at the connection having the part assignment 'Part target', that are editable at the connection. |
Yes |
No |
f29 |
overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f29 |
Project options overview |
Placeholder object |
Properties of the placeholder object in the project option section. |
Yes |
No |
f29 |
Project options overview |
Project option |
Project option properties. |
No |
No |
f29 |
Project options overview |
Project option section |
Properties of the project option section. |
Yes |
No |
f30 |
Placeholder object overview |
Device |
Properties of all functions in the placeholder object that can be variably assigned (always with dynamic line adjustment: a line is output for each variable assignment). |
No |
No |
f30 |
Placeholder object overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f30 |
Placeholder object overview |
Placeholder object |
Properties of the placeholder object. |
No |
No |
f30 |
Placeholder object overview |
Page |
Properties of the page where the placeholder object is placed. |
No |
No |
f30 |
Placeholder object overview |
Value set table |
Placeholder object data for the value set table. The property Value set name outputs the names of the value sets in indexed format. The property Result from value set outputs the content of the value sets in indexed format. For each value set, all possible assignments to the function properties are output (i.e., all possible values that can take the property of the function through an assignment of the value set are output). The property Placeholder format outputs all variable assignments entered in the placeholder object (i.e., the entries from the Variable column on the Assignment tab in the Placeholder object dialog). |
No |
No |
f31 |
Manufacturer / supplier list |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f31 |
Manufacturer / supplier list |
Manufacturer / supplier |
Manufacturer and supplier properties. |
No |
No |
f32 |
Mounting list |
Part |
Properties of the nth part entered at the device. To be used for the data area of the report. |
No |
No |
f32 |
Mounting list |
Part (header) |
Properties of the nth part entered at the device. To be used for the header area of the report. |
No |
Yes |
f32 |
Mounting list |
Part placement |
Properties of the part placement for the data area of the report. If there are several part placements for a part, the properties of the different representation types are combined. |
No |
No |
f32 |
Mounting list |
Part placement (header) |
Properties of the part placement for the header area of the report. If there are several part placements for a part, the properties of the different representation types are combined. |
No |
Yes |
f32 |
Mounting list |
Part reference |
Properties of the nth part entered at the device, that can be edited at the device. To be used for the data area of the report. |
No |
No |
f32 |
Mounting list |
Part reference (header) |
Properties of the nth part entered at the device, that can be edited at the device. To be used for the header area of the report. |
No |
Yes |
f32 |
Mounting list |
Device |
Properties of the device including the device tag. To be used for the data area of the report. |
No |
No |
f32 |
Mounting list |
Device (header) |
Properties of the device including the device tag. To be used for the header area of the report. |
No |
Yes |
f32 |
Mounting list |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f34 |
: Routing path list |
Part (source) |
Properties of the nth part entered at the source device. |
Yes |
No |
f34 |
Topology: Routing path list |
Part (target) |
Properties of the nth part entered at the target device. |
Yes |
No |
f34 |
Topology: Routing path list |
Part reference (source) |
Properties of the nth part entered at the source device, that can be edited at the device. |
Yes |
No |
f34 |
Topology: Routing path list |
Part reference (target) |
Properties of the nth part entered at the target device, that can be edited at the device. |
Yes |
No |
f34 |
Topology: Routing path list |
Device (source) |
Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
No |
No |
f34 |
Topology: Routing path list |
Device (target) |
Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
No |
No |
f34 |
Topology: Routing path list |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f34 |
Topology: Routing path list |
Routing path (topology) |
Properties of the routing path. |
No |
No |
f34 |
Topology: Routing path list |
Routing path part (topology) |
Properties of the nth part entered at the routing path. |
Yes |
No |
f34 |
Topology: Routing path list |
Routing path part reference (topology) |
Properties of the nth part entered at the routing path that are changeable at the routing path. |
Yes |
No |
f35 |
Topology: Routing path diagram |
Device (source) |
Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
Yes |
No |
f35 |
Topology: Routing path diagram |
Device (target) |
Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
Yes |
No |
f35 |
Topology: Routing path diagram |
Cable / connection |
Properties of the cable or connection. |
No |
No |
f35 |
Topology: Routing path diagram |
Cable / Connection part |
Properties of the nth part entered at the cable or connection having the part assignments 'Main part' and 'Accessories'. |
Yes |
No |
f35 |
Topology: Routing path diagram |
Cable / Connection part (assignment: source) |
Properties of the nth part entered at the cable or connection having the part assignment 'Parts source'. |
Yes |
No |
f35 |
Topology: Routing path diagram |
Cable / Connection part (assignment: target) |
Properties of the nth part entered at the cable or connection having the part assignment 'Parts target'. |
Yes |
No |
f35 |
Topology: Routing path diagram |
Cable / Connection part reference |
Properties of the nth part entered at the cable or connection having the part assignments 'Main part' and 'Accessories', which are changeable at the cable / connection. |
Yes |
No |
f35 |
Topology: Routing path diagram |
Cable / Connection part reference (assignment: source) |
Properties of the nth part entered at the cable or connection having the part assignment 'Parts source', which are changeable at the cable / connection. |
Yes |
No |
f35 |
Topology: Routing path diagram |
Cable / Connection part reference (assignment: target) |
Properties of the nth part entered at the cable or connection having the part assignment 'Parts target', which are changeable at the cable / connection. |
Yes |
No |
f35 |
Topology: Routing path diagram |
Routing path (topology) |
Properties of the routing path. |
No |
Yes |
f35 |
Topology: Routing path diagram |
Routing path part (topology) |
Properties of the nth part entered at the routing path. |
Yes |
Yes |
f35 |
Topology: Routing path diagram |
Routing path part reference (topology) |
Properties of the nth part entered at the routing path that are changeable at the routing path. |
Yes |
Yes |
f36 |
Topology: Routed / connections |
Part (source) |
Properties of the nth part entered at the source device. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Part (target) |
Properties of the nth part entered at the target device. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Part reference (source) |
Properties of the nth part entered at the source device, that can be edited at the device. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Part reference (target) |
Properties of the nth part entered at the target device, that can be edited at the device. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Device (source) |
Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Device (target) |
Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Cable / connection |
Properties of the cable or connection. |
No |
No |
f36 |
Topology: Routed cables / connections |
Cable / Connection part |
Properties of the nth part entered at the cable or connection having the part assignments 'Main part' and 'Accessories'. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Cable / Connection part (assignment: source) |
Properties of the nth part entered at the cable or connection having the part assignment 'Parts source'. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Cable / Connection part (assignment: target) |
Properties of the nth part entered at the cable or connection having the part assignment 'Parts target'. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Cable / Connection part reference |
Properties of the nth part entered at the cable or connection having the part assignments 'Main part' and 'Accessories', which are changeable at the cable / connection. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Cable / Connection part reference (assignment: source) |
Properties of the nth part entered at the cable or connection having the part assignment 'Parts source', which are changeable at the cable / connection. |
Yes |
No |
f36 |
Topology: Routed cables / connections |
Cable / Connection part reference (assignment: target) |
Properties of the nth part entered at the cable or connection having the part assignment 'Parts target', which are changeable at the cable / connection. |
Yes |
No |
f37 |
P&I diagram: Piping overview |
Device |
Properties of all the functions contained in the piping. |
Yes |
No |
f37 |
P&I diagram: Piping overview |
Device (source) |
Properties of the source device. The source and target of a defined piping are determined in accordance with the same rules as at connections. |
Yes |
No |
f37 |
P&I diagram: Piping overview |
Device (target) |
Properties of the target device. The source and target of a defined piping are determined in accordance with the same rules as at connections. |
Yes |
No |
f37 |
P&I diagram: Piping overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f37 |
P&I diagram: Piping overview |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f37 |
P&I diagram: Piping overview |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f37 |
P&I diagram: Piping overview |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f37 |
P&I diagram: Piping overview |
Pipe class |
Properties of the pipe class. |
No |
No |
f37 |
P&I diagram: Piping overview |
Piping |
Properties of the piping. |
No |
No |
f37 |
P&I diagram: Piping overview |
Piping planning object |
Properties of the piping planning object. |
No |
No |
f37 |
P&I diagram: Piping overview |
Substance |
Properties of the substance. |
No |
No |
f38 |
Pre-planning: Structure segment overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f38 |
Pre-planning: Structure segment overview |
Placement pre-planning |
Properties of the placement of the structure segment in the pre-planning, for example the page name. |
No |
No |
f38 |
Pre-planning: Structure segment overview |
Page |
Properties of the nth page that is assigned to the structure segment. |
Yes |
No |
f38 |
Pre-planning: Structure segment overview |
Structure segment |
Properties of the structure segment. |
No |
No |
f38 |
Pre-planning: Structure segment overview |
Structure segment hierarchical |
Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure are determined starting from the highest structure level (this corresponds to the project). |
Yes |
No |
f38 |
Pre-planning: Structure segment overview |
Structure segment hierarchical |
Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). |
Yes |
No |
f38 |
Pre-planning: Structure segment overview |
Linked with superior segments |
Properties of the segment below which the n-th link is inserted. |
Yes |
No |
f38 |
Pre-planning: Structure segment overview |
Linked segments |
Properties of the n-th linked segment. |
Yes |
No |
f39 |
Pre-planning: Structure segment plan |
Part |
Properties of the nth part entered at the subordinate planning object. |
Yes |
No |
f39 |
Pre-planning: Structure segment plan |
Part reference |
Properties of the nth part entered at the subordinate planning object, that can be edited at the planning object. |
Yes |
No |
f39 |
Pre-planning: Structure segment plan |
Device |
Properties of the device that the subordinate planning object is assigned to. |
No |
No |
f39 |
Pre-planning: Structure segment plan |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f39 |
Pre-planning: Structure segment plan |
Function |
Properties of the nth function that is assigned to the subordinate planning object. |
Yes |
No |
f39 |
Pre-planning: Structure segment plan |
Placement P&I diagram |
Properties of the n-th placement (in accordance with the graphical order) of the structure segment in the P&I diagram, for example the page name. |
Yes |
No |
f39 |
Pre-planning: Structure segment plan |
Placement pre-planning |
Properties of the placement of the structure segment in the pre-planning, for example the page name. |
No |
No |
f39 |
Pre-planning: Structure segment plan |
Placement pre-planning (header) |
Properties of the placement of the structure segment in the pre-planning, for example the page name. To be used for the header area of the report. |
No |
Yes |
f39 |
Pre-planning: Structure segment plan |
Page |
Properties of the nth page that is assigned to the structure segment. |
Yes |
Yes |
f39 |
Pre-planning: Structure segment plan |
|
Properties of the nth PLC address that is assigned to the subordinate planning object. |
Yes |
No |
f39 |
Pre-planning: Structure segment plan |
Structure segment (header) |
Properties of the structure segment. To be used for the header area of the report. |
No |
Yes |
f39 |
Pre-planning: Structure segment plan |
Structure segment / Planning object |
Properties of the subordinate structure segment or planning object. To be used for the data area of the report. |
No |
No |
f39 |
Pre-planning: Structure segment plan |
Structure segment hierarchical |
Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). |
Yes |
Yes |
f39 |
Pre-planning: Structure segment plan |
Structure segment hierarchical |
Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). |
Yes |
Yes |
f39 |
Pre-planning: Structure segment plan |
Linked with superior segments |
Properties of the segment below which the n-th link is inserted. |
Yes |
Yes |
f39 |
Pre-planning: Structure segment plan |
Linked segments |
Properties of the n-th linked segment. |
Yes |
Yes |
f40 |
Pre-planning: Planning object overview |
Part |
Properties of the nth part entered at the planning object. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Part reference |
Properties of the nth part entered at the planning object, that can be edited at the planning object. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Device |
Properties of the device that is assigned to the planning object. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Function |
Properties of the nth function that is assigned to the planning object. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Planning object |
Properties of the planning object. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Placement P&I diagram |
Properties of the n-th placement (in accordance with the graphical order) of the planning object in the P&I diagram, for example the page name. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Placement pre-planning |
Properties of the placement of the planning object in the pre-planning, for example the page name. |
No |
No |
f40 |
Pre-planning: Planning object overview |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f40 |
Pre-planning: Planning object overview |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Source segment |
Properties of the segment that is the source of the connection planning object. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Pipe class |
Properties of the pipe class. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Piping definition |
Properties of the piping definition. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Piping planning object |
Properties of the piping planning object. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Page |
Properties of the nth page that is assigned to the planning object. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
PLC addresses |
Properties of the nth PLC address that is assigned to the planning object. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Substance |
Properties of the substance. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Structure segment hierarchical |
Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Structure segment hierarchical |
Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Superior segment |
Properties of the superior segment. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Superior segment |
Properties of the superior segment. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Superior structure segment |
Properties of the superior structure segment. |
No |
No |
f40 |
Pre-planning: Planning object overview |
Subordinate segment |
Properties of the nth subordinate planning object. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Subordinate segment |
Properties of the nth subordinate planning object. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Linked with superior segments |
Properties of the segment below which the n-th link is inserted. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Linked segments |
Properties of the n-th linked segment. |
Yes |
No |
f40 |
Pre-planning: Planning object overview |
Target segment |
Properties of the segment that is the target of the connection planning object. |
No |
No |
f41 |
Pre-planning: Planning object plan |
Part |
Properties of the nth part entered at the planning object. |
Yes |
No |
f41 |
Pre-planning: Planning object plan |
Part (header) |
Properties of the nth part entered at the planning object. To be used for the header area of the report. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Part reference |
Properties of the nth part entered at the planning object, that can be edited at the planning object. To be used for the data area of the report. |
Yes |
No |
f41 |
Pre-planning: Planning object plan |
Part reference (header) |
Properties of the nth part entered at the planning object, that can be edited at the planning object. To be used for the header area of the report. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Device |
Properties of the device that is assigned to the planning object, including device tag. To be used for the data area of the report. |
No |
No |
f41 |
Pre-planning: Planning object plan |
Device (header) |
Properties of the device that is assigned to the planning object, including device tag. To be used for the header area of the report. |
No |
Yes |
f41 |
Pre-planning: Planning object plan |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f41 |
Pre-planning: Planning object plan |
Function |
Properties of the nth function that is assigned to the planning object. To be used for the data area of the report. |
Yes |
No |
f41 |
Pre-planning: Planning object plan |
Function (header) |
Properties of the nth function that is assigned to the planning object. To be used for the header area of the report. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Planning object |
Properties of the planning object. To be used for the data area of the report. |
No |
No |
f41 |
Pre-planning: Planning object plan |
Planning object (header) |
Properties of the planning object. To be used for the header area of the report. |
No |
Yes |
f41 |
Pre-planning: Planning object plan |
Placement P&I diagram |
Properties of the n-th placement (in accordance with the graphical order) of the planning object in the P&I diagram, for example the page name. |
Yes |
No |
f41 |
Pre-planning: Planning object plan |
Placement P&I diagram (header) |
Properties of the n-th placement (in accordance with the graphical order) of the planning object in the P&I diagram, for example the page name. To be used for the header area of the report. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Placement pre-planning |
Properties of the placement of the planning object in the pre-planning, for example the page name. |
No |
No |
f41 |
Pre-planning: Planning object plan |
Placement pre-planning (header) |
Properties of the placement of the planning object in the pre-planning, for example the page name. To be used for the header area of the report. |
No |
Yes |
f41 |
Pre-planning: Planning object plan |
PCT loop (header) |
Properties of the associated PCT loop. To be used for the header area of the report. |
No |
Yes |
f41 |
Pre-planning: Planning object plan |
PCT loop function (header) |
Properties of the associated PCT loop function. To be used for the header area of the report. |
No |
Yes |
f41 |
Pre-planning: Planning object plan |
Source segment |
Properties of the segment that is the source of the connection planning object. To be used for the data area of the report. |
No |
No |
f41 |
Pre-planning: Planning object plan |
Source segment (header) |
Properties of the segment that is the source of the connection planning object. To be used for the data area of the report. |
No |
Yes |
f41 |
Pre-planning: Planning object plan |
Pipe class (header) |
Properties of the pipe class selected at the planning object. To be used for the header area of the report. |
No |
Yes |
f41 |
Pre-planning: Planning object plan |
Piping definition |
Properties of the piping definition. |
Yes |
No |
f41 |
Pre-planning: Planning object plan |
Piping definition (header) |
Properties of the piping definition. To be used for the header area of the report. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Piping planning object |
Properties of the piping planning object. To be used for the data area of the report. |
Yes |
No |
f41 |
Pre-planning: Planning object plan |
Piping planning object (header) |
Properties of the piping planning object. To be used for the header area of the report. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Page |
Properties of the nth page that is assigned to the planning object. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
PLC addresses |
Properties of the nth PLC address that is assigned to the planning object. To be used for the data area of the report. |
Yes |
No |
f41 |
Pre-planning: Planning object plan |
PLC addresses (header) |
Properties of the nth PLC address that is assigned to the planning object. To be used for the header area of the report. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Substance (header) |
Properties of the substance selected at the planning object. To be used for the header area of the report. |
No |
Yes |
f41 |
Pre-planning: Planning object plan |
Structure segment hierarchical |
Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Structure segment hierarchical |
Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Superior segment (header) |
Properties of the superior segment. To be used for the header area of the report. |
No |
Yes |
f41 |
Pre-planning: Planning object plan |
Linked with superior segments |
Properties of the segment below which the n-th link is inserted. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Linked segments |
Properties of the n-th linked segment. |
Yes |
Yes |
f41 |
Pre-planning: Planning object plan |
Target segment |
Properties of the segment that is the target of the connection planning object. To be used for the data area of the report. |
No |
No |
f41 |
Pre-planning: Planning object plan |
Target segment (header) |
Properties of the segment that is the target of the connection planning object. To be used for the data area of the report. |
No |
Yes |
f42 |
Pre-planning: Segment template overview |
Part |
Properties of the nth part entered at the segment template. |
Yes |
No |
f42 |
Pre-planning: Segment template overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f42 |
Pre-planning: Segment template overview |
Segment template |
Properties of the segment template. |
No |
No |
f43 |
Pre-planning: Segment template plan |
Part |
Properties of the nth part entered at the segment template. To be used for the header area of the report. |
Yes |
Yes |
f43 |
Pre-planning: Segment template plan |
Part reference |
Properties of the nth part entered at the segment template that are changeable at the segment template. To be used for the data area of the report. |
Yes |
No |
f43 |
Pre-planning: Segment template plan |
Device |
Properties of the device that is assigned to the subordinate planning object, including device tag. |
No |
No |
f43 |
Pre-planning: Segment template plan |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f43 |
Pre-planning: Segment template plan |
Function |
Properties of the nth function that is assigned to the subordinate planning object. |
Yes |
No |
f43 |
Pre-planning: Segment template plan |
Planning object |
Properties of the subordinate planning object. |
No |
No |
f43 |
Pre-planning: Segment template plan |
Segment template |
Properties of the segment template. To be used for the header area of the report. |
No |
Yes |
f43 |
Pre-planning: Segment template plan |
PLC addresses |
Properties of the nth PLC address that is assigned to the segment template. |
Yes |
No |
f44 |
Assembly/Module Overview |
Part |
Properties of the part within the assembly. To be used for the data area of the report. |
No |
No |
f44 |
Assembly/Module Overview |
Part (header) |
Properties of the assembly. To be used for the header area of the report. |
No |
Yes |
f44 |
Assembly/Module Overview |
Part reference |
Properties of the part within the assembly that can be changed at the function / segment. To be used for the data area of the report. |
No |
No |
f44 |
Assembly/Module Overview |
Part reference (header) |
Properties of the assembly that can be changed at the function / segment. To be used for the header area of the report. |
No |
Yes |
f44 |
Assembly/Module Overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f45 |
Distributed device list |
Part |
Properties of the nth part entered at the device. |
Yes |
Yes |
f45 |
Distributed device list |
Part reference |
Properties of the nth part entered at the device, that can be edited at the device. |
Yes |
Yes |
f45 |
Distributed device list |
Device tag |
Structure identifiers, components of the device tag. |
No |
Yes |
f45 |
Distributed device list |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f45 |
Distributed device list |
Function |
Properties of the function. |
No |
No |
f46 |
Conduit / line plan |
Part |
Properties of the nth part entered at the conduit / line having the part assignments 'Main part' and 'Accessories'. |
Yes |
Yes |
f46 |
Conduit / line plan |
Part reference |
Properties of the nth part entered at the conduit / line having the part assignments 'Main part' and 'Accessories', that are editable at the conduit / line . |
Yes |
Yes |
f46 |
Conduit / line plan |
Device (source) |
Properties of the source device. Source and target of the conduit are determined according to particular rules from the properties of the conductors contained by the conduit. |
No |
No |
f46 |
Conduit / line plan |
Device (target) |
Properties of the target device. Source and target of the conduit are determined according to particular rules from the properties of the conductors contained by the conduit. |
No |
No |
f46 |
Conduit / line plan |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f46 |
Conduit / line plan |
Conduit / line |
Properties of the conduit or line. |
No |
Yes |
f46 |
Conduit / line plan |
PCT loop |
Properties of the associated PCT loop. |
No |
Yes |
f46 |
Conduit / line plan |
PCT loop function |
Properties of the associated PCT loop function. |
No |
Yes |
f46 |
Conduit / line plan |
Connection |
Properties of the connections in the conduit / line. |
No |
No |
f46 |
Conduit / line plan |
Connection part |
Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories'. |
Yes |
No |
f46 |
Conduit / line plan |
Connection part reference |
Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories', that are editable at the connection. |
Yes |
No |
f46 |
Conduit / line plan |
Pre-planning segment |
Properties of the nth segment that is assigned to the conduit / line. |
Yes |
Yes |
f46 |
Conduit / line plan |
Pre-planning segment |
Properties of the nth segment that is assigned to the conduit / line. |
Yes |
Yes |
f47 |
Cut-out legend |
3D model view |
Properties of the 2D drilling view in which the cut-out is located. |
No |
Yes |
f47 |
Cut-out legend |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f47 |
Cut-out legend |
Cut-out |
Properties of the cut-out. |
No |
No |
f48 |
PLC address overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f48 |
PLC address overview |
PCT loop |
Properties of the associated PCT loop. |
No |
No |
f48 |
PLC address overview |
PCT loop function |
Properties of the associated PCT loop function. |
No |
No |
f48 |
PLC address overview |
PLC addresses |
Properties that are entered for a PLC address in the assignment list row. |
No |
No |
f48 |
PLC address overview |
PLC connection point |
Properties of the nth PLC connection point that the PLC address is assigned to. |
Yes |
No |
f48 |
PLC address overview |
Pre-planning segment |
Properties of the segment that the PLC address is assigned to. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f48 |
PLC address overview |
Pre-planning segment |
Properties of the segment that the PLC address is assigned to. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. |
Yes |
No |
f49 |
Preplanning: Pipe class overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f49 |
Preplanning: Pipe class overview |
Pipe class |
Properties of the pipe class. |
No |
No |
f51 |
Preplanning: Substance overview |
Record |
General properties of records in the report, e.g. for entering a row number. |
No |
No |
f51 |
Preplanning: Substance overview |
Substance |
Properties of the substance. |
No |
No |