Parameters |
Description |
TYPE |
Type of task that the action is to perform: |
|
Project name with complete file path (optional). |
|
Specifies whether the current selection in the user interface is to be taken into account during numbering (optional, 0 = No, 1 = Yes). |
|
Name of the filter scheme (optional). |
|
Numbering scheme (optional). |
|
Start value for the numbering (optional). |
|
Increment; value by which the counter is increased (optional). Default value: |
|
Renumbering of the devices that are marked with a flag "?" (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Also number those controlled by PLC (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Allow change in sorting (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Fill gaps (optional, 0 = No, 1 = Yes). |
|
Identifiers (e.g. "X*", optional). If this parameter is used, all devices from the project which correspond to the identifier are renumbered, irrespectively of whether the |
|
Corresponds to the setting Also number cables whose DT contain source / target: (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Structure-oriented numbering (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Keep interval (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Keep text (optional, 0 = No, 1 = Yes). |
|
Corresponds to the Subpages setting (optional). |
|
Corresponds to the setting Prefix (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Suffix (optional, 0 = No, 1 = Yes). |
|
Corresponds to the Sequence setting (optional). |
|
Corresponds to the Extent setting (optional). |
|
Corresponds to the N terminals / pins setting (optional). |
|
Corresponds to the PE terminals / pins setting (optional). |
|
Corresponds to the SH terminals / pins setting (optional). |
|
Corresponds to the Multiple terminals setting (optional). |
|
Corresponds to the Terminals with alphabetical characters setting (optional). |
|
Corresponds to the setting Keep existing cable DTs (optional). Possible values are: 0 = No (default value), 1 = Yes. 0 = All cable DTs are renumbered. 1 = Only newly generated or copied cables are renumbered. The DT of the already numbered cables is retained. Only cables with the character "?" in the identifier are numbered. Only available if the TYPE parameter has the following value: |
|
Corresponds to the Keep identifier setting (optional). Possible values are: 0 = No (default value), 1 = Yes. 0 = Overwrites the identifiers of the cables with the identifiers from the identifier set used for numbering. 1 = Renumber existing cables and in the process only reassign the counters. The identifier of the already numbered cables remains. The character "?" at the beginning of the identifier is not retained. Only available if the TYPE parameter has the following value: |
|
Start value for the numbering of connection groups (optional). |
|
Increment for the numbering of connection groups; value by which the counter is increased (optional). Default value: |
|
Connection group (optional). Only available if the TYPE parameter has the following value: |
|
Overwrite mode (optional). |
|
Corresponds to the Avoid identical designations setting (optional). |
|
Corresponds to the Visibility setting (optional). |
|
Corresponds to the Mark as 'manually set' setting (optional). Only available if the TYPE parameter has the following value: |
Number devices:
Renumber /TYPE:DEVICES /STARTVALUE:1 /STEPVALUE:1 /USESELECTION:0 /IDENTIFIER:X* /CONFIGSCHEME:"Kennbuchstabe Zähler" /POSTNUMERATE:0
Number pages:
Renumber /TYPE:PAGES /STRUCTUREORIENTED:0 /STARTVALUE:3 /STEPVALUE:10 /KEEPINTERVAL:1 /KEEPTEXT:0 /SUBPAGES:1 /USESELECTION:0
Number cables:
Renumber /CONFIGSCHEME:Standard /TYPE:CABLES /STARTVALUE:7 /STEPVALUE:7 /USESELECTION:1 /KEEPEXISTING:1
renumber /CONFIGSCHEME:Standard /TYPE:CABLES /STARTVALUE:1 /STEPVALUE:1 /USESELECTION:0 /KEEPEXISTING:0 /KEEPIDENTIFIER:1
renumber /TYPE:CABLES /STARTVALUE:999 /USESELECTION:0
Number connections:
Renumber /TYPE:CONNECTIONS /CONFIGSCHEME: Potenzialorientiert /STARTVALUE_1:13 /STEPVALUE_1:3 /OVERWRITE:0 /AVOIDIDENTICALDESIGNATIONS:0 /VISIBILITY:1 /MARKASMANUAL:1 /USESELECTION:0 /GROUP_1:1
Number terminals:
Renumber /TYPE:TERMINALS /CONFIGSCHEME:Numerisch /SEQUENCE:1 /POTENTIAL_N:1 /POTENTIAL_PE:2 /POTENTIAL_SH:2 /POSTNUMERATE:0 /ALSONUMERATEDBYPLC:1 /MULTIPLETERMINALS:1 /KEEPALPHA:0 /STARTVALUE:1 /STEPVALUE:1 /PREFIX:p_ /SUFFIX:_s /USESELECTION:1