This functionality is only available for certain module packages. Info / Copyright

P003007: Multiple cable targets

Cause

You have numbered a cable that has more than one cable target. In the process a numbering format is selected that outputs the device tag of the target as a counter in the device tag of the cable, for example -W(=ANL+EBO-X5/=ANL+EBO-H3). A conflict occurred since more than one cable target is available but only one target designation can be output.

Note:

You access the numbering settings for cables by first selecting the cable in the schematic and then selecting the following commands: Tab Connections > Command group Cables > Number. Then click [...] in the Settings field of the Number cables dialog. Open the Format drop-down list of the first tab in the Settings: Cable numbering dialog.

Solution

  1. Only assign one cable target to the cable.
  2. Update the connections.
  3. Subsequently number the cable again by using one of the following formats:
  • According to source
  • According to target
  • According to source and target
  • According to target and source

Note:

Using a new check run (any set desired check scheme) this module-specific message can be deleted from the message management dialog.