Cause
The cable has more than one N-conductor.
Solution
Change the potential type at the connection points of the functions that lead in N-wires appearing several times in the cable.
- Call up the respective property dialog at the functions that are the source and / or target of the cable.
- For each function bring the Symbol / function data tab to the front, and click the [Logic] button.
- In the Connection point logic dialog at the function connection points check the value in the Potential type field.
- Then select a different potential type, for example "Undefined", at the function connection points with the value "N" assigned several times.
- Confirm your entries.
- Update the connections.
- If required, start a new check run.