This functionality is only available for certain module packages. Info / Copyright

P003023: Mismatch between quantity of parts and setting for adding up cable lengths

Cause

The property Do not use cable when adding up cable lengths is activated at the cable, and additionally the value "0" is entered in the Number of units / quantity field in the Parts tab of the Cable properties dialog.

Solution

Possibility 1

  1. Double-click the cable definition line and select the Cable tab in the Properties <...> dialog.
  2. Under Properties deselect the check box Do not use cable when adding up cable lengths.

Possibility 2

  1. Double-click on the cable definition line and select the Parts tab in the Properties <...> dialog.
  2. In the Number of units / quantity field enter a value higher than "0" for the cable.


If required, start a new check run.