Cause
For a cable placed in a distributed manner in the schematic, the Function text (automatic) property is different in the selected displayed language at one or several placements of the cable.
Solution
Possibility 1
- Locate the functions of the cable displayed as distributed using the Go to (cross-referenced) functionalities from the popup menu in the Message management dialog.
- In the Search results <Project name> dialog double-click the entered cable definition of the main and auxiliary functions and call up the property dialog of the respective cable definition.
- Standardize the Function text (automatic) property in the selected displayed language for all placements of the cable.
- Confirm your entries.
Possibility 2
Use the synchronization functionality.
- Select one of the cable definition lines of the cable displayed as distributed whose automatic function text is to be transferred to the other functions of the cable.
- Select the following commands: Tab Tools > Command group Synchronization > Drop-down button Functions and decide which type of synchronization you want to perform depending on the representation type. Use, for example, the command Multi-line --> All representation types if you have configured the selected cable definition line whose data you want to transfer as multi-line.
The automatic function texts of the cable displayed as distributed are synchronized correspondingly to each other.
If required, start a new check run.