Cause
The same entry was assigned several times in the language <x> at the Function text (automatic) property at the PLC connection points of a CPU.
Solution
- Locate the PLC connection points in the schematic using the Go to (graphic) functionality from the popup menu in the Message management dialog.
- Modify the function or path function text so that each entry is unique for the corresponding PLC connection points in the reported language.
- Translate the modified function or path function texts into all the further languages used by you.
- If required, start a new check run.
Notes:
- The comparison of the function texts is effected for each language separately.
- Language-neutral (= untranslated) function texts are only compared with untranslated texts. The function texts must therefore be translated (or be translated again after a modification) so that the test functions.
- Empty function texts do not result in a message.