Cause
A connection of the "3D mounting layout" representation type exists in a layout space whose connected source or connected target has a connection point designation that is not defined in the connection point pattern.
Solution
- Locate the connection of the "3D mounting layout" representation type in the layout space using the Go to (graphic) functionality from the popup menu in the Message management dialog.
- Follow the connection in the layout space both up to the connected source and the connected target.
- Check the connection point pattern respectively at the source and at the target by calling up the dialog Properties <...> of the part placement and bringing the tab Connection point pattern to the foreground.
- Delete the connection point designation that does not belong to the connection point pattern and close the Properties <...> dialog by clicking [OK].
- If required, start a new check run.
Note:
The check run is also output when the connection point is defined in the connection point pattern and all values in the columns for the X, Y and Z position are set to "0".
In this case enter a value deviating from "0" for at least one position of the connection point.