P005068: Connection (3D mounting layout) with connection point that is not defined in the connection point pattern

Cause

A connection of the "3D mounting layout" representation type exists in a layout space whose connected source or connected target has a connection point designation that is not defined in the connection point pattern.

Solution

  1. Locate the connection of the "3D mounting layout" representation type in the layout space using the Go to (graphic) functionality from the popup menu in the Message management dialog.
  2. Follow the connection in the layout space both up to the connected source and the connected target.
  3. Check the connection point pattern respectively at the source and at the target by calling up the dialog Properties <...> of the part placement and bringing the tab Connection point pattern to the foreground.
  4. Delete the connection point designation that does not belong to the connection point pattern and close the Properties <...> dialog by clicking [OK].
  5. If required, start a new check run.

Note:

The check run is also output when the connection point is defined in the connection point pattern and all values in the columns for the X, Y and Z position are set to "0".

In this case enter a value deviating from "0" for at least one position of the connection point.