Cause
In the project-specific settings, you have defined a mandatory property <y> for a segment definition <x>. But in the pre-planning, a value was not stored at the defined mandatory property for this segment definition.
Solution
- Locate the output segment definition in question in the project using the Go to (graphic) or Synchronize selection functions offered by the popup menu of the Message management dialog.
- Open the Properties <...> dialog of the segment definition, and bring to the front the corresponding tab that contains the properties.
- Assign a value to the mandatory property output in the Message management dialog for the segment definition, and close the Properties <...> dialog with [OK].
- If required, start a new check run.
Note:
This check run can be configured freely by using the Settings: Pre-planning depth dialog (command path: File > Settings > Projects > "Project name" > Pre-planning > Pre-planning depth).