This functionality is only available for certain module packages. Info / Copyright

P501026: The bus port '<x>' entered in the function templates of the part was not found in single-line representation in the macro '<y>'. The message applies to the part property '<z>'

Cause

In the parts database to be checked, a part was found at which a function template of a bus port '<x>' is defined. The bus port is missing in the single-line representation in the associated macro '<y>' that is stored in the hierarchy level Data of the parts management at the part property '<z>'.

Solution

  1. Add the bus port in the macro in the single-line representation.
  2. Save the change in the macro.
  3. In the parts management store the macro again at the part property.
  4. Close the parts management, save the modified data, and carry out a parts synchronization.


If required, start a new check run.