ID Form type Elements Indexed Header data
f01 Parts list Part Properties of the part stored in the project. No No
f01 Parts list Part placement Properties of the part placement. If there are several part placements for a part, the properties of the different representation types are combined. Yes No
f01 Parts list Part reference Properties of the part that can be changed at the device, and calculated properties. No No
f01 Parts list Part reference manufacturer Properties of the manufacturer that are stated at the part reference (i.e., at the device) and that can be modified. No No
f01 Parts list Part reference supplier Properties of the supplier that are stated at the part reference (i.e., at the device) and that can be modified. No No
f01 Parts list Device Properties of the device that the part is assigned to. No No
f01 Parts list Record General properties of records in the report, e.g. for entering a row number. No No
f01 Parts list Mounting panel Properties of the mounting panel. Yes No
f01 Parts list PCT loop Properties of the associated PCT loop. No No
f01 Parts list PCT loop function Properties of the associated PCT loop function. No No
f01 Parts list Pre-planning segment Properties of the segment that the part is assigned to. Yes No
f01 Parts list Pre-planning segment Properties of the segment that the part is assigned to. Yes No
f02 Summarized parts list Part Properties of the part stored in the project. No No
f02 Summarized parts list Part placement Properties of the part placement. If there are several part placements for a part, the properties of the different representation types are combined. Yes No
f02 Summarized parts list Part reference Properties of the part that can be changed at the device, and calculated properties. No No
f02 Summarized parts list Part reference manufacturer Properties of the manufacturer that are stated at the part reference (i.e., at the device) and that can be modified. No No
f02 Summarized parts list Part reference supplier Properties of the supplier that are stated at the part reference (i.e., at the device) and that can be modified. No No
f02 Summarized parts list Device Properties of the device that the part is assigned to. No No
f02 Summarized parts list Record General properties of records in the report, e.g. for entering a row number. No No
f02 Summarized parts list Mounting panel Properties of the mounting panel. Yes No
f02 Summarized parts list PCT loop Properties of the associated PCT loop. No No
f02 Summarized parts list PCT loop function Properties of the associated PCT loop function. No No
f02 Summarized parts list Pre-planning segment Properties of the segment that the part is assigned to. Yes No
f02 Summarized parts list Pre-planning segment Properties of the segment that the part is assigned to. Yes No
f03 Device tag list Connected PLC connection point Properties of the PLC connection point that is connected to the nth function of the device. Yes No
f03 Device tag list Part Properties of the nth part entered at the device. Yes No
f03 Device tag list Part reference Properties of the nth part entered at the device, that can be edited at the device. Yes No
f03 Device tag list Device tag Structure identifiers, components of the device tag. No No
f03 Device tag list Record General properties of records in the report, e.g. for entering a row number. No No
f03 Device tag list Function Properties of the nth function of the device. Yes No
f03 Device tag list Device group (further functions) Properties of the nth function of the device group. Without an index value, all functions of the device group are output, except for the currently reported-on function. Yes No
f03 Device tag list PCT loop Properties of the associated PCT loop. No No
f03 Device tag list PCT loop function Properties of the associated PCT loop function. No No
f03 Device tag list Pre-planning segment Properties of the nth segment that is assigned to the device. Yes No
f03 Device tag list Pre-planning segment Properties of the nth segment that is assigned to the device. Yes No
f04 Forms documentation Record General properties of records in the report, e.g. for entering a row number. No No
f04 Forms documentation Form Properties of the form. No No
f05 Device-connection diagram Connected PLC connection point Properties of the PLC connection point that is connected to the device connection point. No No
f05 Device-connection diagram Connection point, external Properties of the nth external connection point of the device. No No
f05 Device-connection diagram Connection point, internal Properties of the nth internal connection point of the device. No No
f05 Device-connection diagram Part Properties of the nth part entered at the device. Yes Yes
f05 Device-connection diagram Part reference Properties of the nth part entered at the device, that can be edited at the device. Yes Yes
f05 Device-connection diagram Device Properties of the device including the device tag. No Yes
f05 Device-connection diagram Function Properties of the function belonging to the connection point. No No
f05 Device-connection diagram Cable, external 'level (1-3)' Properties of the externally connected cable at the nth level. Yes No
f05 Device-connection diagram Cable, internal 'level (1-3)' Properties of the internally connected cable at the nth level. Yes No
f05 Device-connection diagram Last external target Properties of the last externally connected function found during target tracking. No No
f05 Device-connection diagram Last internal target Properties of the last internally connected function found during target tracking. No No
f05 Device-connection diagram PCT loop Properties of the associated PCT loop. No Yes
f05 Device-connection diagram PCT loop function Properties of the associated PCT loop function. No Yes
f05 Device-connection diagram Connection, external 'level (1-3)' Properties of the externally connected connection at the nth level. Yes No
f05 Device-connection diagram Connection, internal 'level (1-3)' Properties of the internally connected connection at the nth level. Yes No
f05 Device-connection diagram Pre-planning segment Properties of the segment that is assigned to the device. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f05 Device-connection diagram Pre-planning segment Properties of the segment that is assigned to the device. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f05 Device-connection diagram Target, external, connection point 'level (1-3)' Properties of the connection point of the externally connected function at the nth level. Yes No
f05 Device-connection diagram Target, external, counter-connection 'level (1-3)' Properties of the continuing connection point of the externally connected function at the nth level. Yes No
f05 Device-connection diagram Target, external 'level (1-3)' Properties of the externally connected function at the nth level. Yes No
f05 Device-connection diagram Target, internal, connection point 'level (1-3)' Properties of the connection point of the internally connected function at the nth level. Yes No
f05 Device-connection diagram Target, internal, counter-connection 'level (1-3)' Properties of the continuing connection point of the internally connected function at the nth level. Yes No
f05 Device-connection diagram Target, internal 'level (1-3)' Properties of the internally connected function at the nth level. Yes No
f06 Table of contents Record General properties of records in the report, e.g. for entering a row number. No No
f06 Table of contents PCT loop Properties of the associated PCT loop. No No
f06 Table of contents PCT loop function Properties of the associated PCT loop function. No No
f06 Table of contents Project Properties of the project. No No
f06 Table of contents Page Properties of the page. No No
f06 Table of contents Pre-planning segment Properties of the segment that the page is assigned to. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f06 Table of contents Pre-planning segment Properties of the segment that the page is assigned to. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f07 Cable-connection diagram Cable Properties of the cable. No Yes
f07 Cable-connection diagram Cable, external 'level (1-3)' Properties of the externally connected cable at the nth level. Yes No
f07 Cable-connection diagram Cable, internal 'level (1-3)' Properties of the internally connected cable at the nth level. Yes No
f07 Cable-connection diagram Cable part Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories'. Yes Yes
f07 Cable-connection diagram Cable part (assignment: source) Properties of the nth part entered at the cable having the part assignment 'Part source'. Yes Yes
f07 Cable-connection diagram Cable part (assignment: target) Properties of the nth part entered at the cable having the part assignment 'Part target'. Yes Yes
f07 Cable-connection diagram Cable part reference Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories', that are editable at the cable. Yes Yes
f07 Cable-connection diagram Cable part reference (assignment: source) Properties of the nth part entered at the cable having the part assignment 'Part source', that are editable at the cable. Yes Yes
f07 Cable-connection diagram Cable part reference (assignment: target) Properties of the nth part entered at the cable having the part assignment 'Part target', that are editable at the cable. Yes Yes
f07 Cable-connection diagram Cable connection Properties of the conductors / connections contained in the cable. No No
f07 Cable-connection diagram Last external target Properties of the last externally connected function found during target tracking. No No
f07 Cable-connection diagram Last internal target Properties of the last internally connected function found during target tracking. No No
f07 Cable-connection diagram PCT loop Properties of the associated PCT loop. No Yes
f07 Cable-connection diagram PCT loop function Properties of the associated PCT loop function. No Yes
f07 Cable-connection diagram Connection, external 'level (1-3)' Properties of the externally connected connection at the nth level. Yes No
f07 Cable-connection diagram Connection, internal 'level (1-3)' Properties of the internally connected connection at the nth level. Yes No
f07 Cable-connection diagram Pre-planning segment Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f07 Cable-connection diagram Pre-planning segment Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f07 Cable-connection diagram Target, external, connection point 'level (1-3)' Properties of the connection point of the externally connected function at the nth level. Yes No
f07 Cable-connection diagram Target, external, counter-connection 'level (1-3)' Properties of the continuing connection point of the externally connected function at the nth level. Yes No
f07 Cable-connection diagram Target, external 'level (1-3)' Properties of the externally connected function at the nth level. Yes No
f07 Cable-connection diagram Target, internal, connection point 'level (1-3)' Properties of the connection point of the internally connected function at the nth level. Yes No
f07 Cable-connection diagram Target, internal, counter-connection 'level (1-3)' Properties of the continuing connection point of the internally connected function at the nth level. Yes No
f07 Cable-connection diagram Target, internal 'level (1-3)' Properties of the internally connected function at the nth level. Yes No
f08 Cable assignment diagram Part (source) Properties of the nth part entered at the source device. Yes No
f08 Cable assignment diagram Part (target) Properties of the nth part entered at the target device. Yes No
f08 Cable assignment diagram Part reference (source) Properties of the nth part entered at the source device, that can be edited at the device. Yes No
f08 Cable assignment diagram Part reference (target) Properties of the nth part entered at the target device, that can be edited at the device. Yes No
f08 Cable assignment diagram Device (source) Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. Yes No
f08 Cable assignment diagram Device (target) Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. Yes No
f08 Cable assignment diagram Record General properties of records in the report, e.g. for entering a row number. No No
f08 Cable assignment diagram Cable Properties of the cable. No No
f08 Cable assignment diagram Cable part Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories'. Yes No
f08 Cable assignment diagram Cable part (assignment: source) Properties of the nth part entered at the cable having the part assignment 'Part source'. Yes No
f08 Cable assignment diagram Cable part (assignment: target) Properties of the nth part entered at the cable having the part assignment 'Part target'. Yes No
f08 Cable assignment diagram Cable part reference Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories', that are editable at the cable. Yes No
f08 Cable assignment diagram Cable part reference (assignment: source) Properties of the nth part entered at the cable having the part assignment 'Part source', that are editable at the cable. Yes No
f08 Cable assignment diagram Cable part reference (assignment: target) Properties of the nth part entered at the cable having the part assignment 'Part target', that are editable at the cable. Yes No
f08 Cable assignment diagram PCT loop Properties of the associated PCT loop. No No
f08 Cable assignment diagram PCT loop function Properties of the associated PCT loop function. No No
f08 Cable assignment diagram Pre-planning segment Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f08 Cable assignment diagram Pre-planning segment Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f09 Cable diagram Part (source) Properties of the nth part entered at the source device. Yes No
f09 Cable diagram Part (target) Properties of the nth part entered at the target device. Yes No
f09 Cable diagram Part reference (source) Properties of the nth part entered at the source device, that can be edited at the device. Yes No
f09 Cable diagram Part reference (target) Properties of the nth part entered at the target device, that can be edited at the device. Yes No
f09 Cable diagram Device (source) Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. No No
f09 Cable diagram Device (target) Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. No No
f09 Cable diagram Record General properties of records in the report, e.g. for entering a row number. No No
f09 Cable diagram Cable Properties of the cable. No Yes
f09 Cable diagram Cable part Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories'. Yes Yes
f09 Cable diagram Cable part (assignment: source) Properties of the nth part entered at the cable having the part assignment 'Part source'. Yes Yes
f09 Cable diagram Cable part (assignment: target) Properties of the nth part entered at the cable having the part assignment 'Part target'. Yes Yes
f09 Cable diagram Cable part reference Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories', that are editable at the cable. Yes Yes
f09 Cable diagram Cable part reference (assignment: source) Properties of the nth part entered at the cable having the part assignment 'Part source', that are editable at the cable. Yes Yes
f09 Cable diagram Cable part reference (assignment: target) Properties of the nth part entered at the cable having the part assignment 'Part target', that are editable at the cable. Yes Yes
f09 Cable diagram Cable connection Properties of the conductors / connections contained in the cable. No No
f09 Cable diagram PCT loop Properties of the associated PCT loop. No Yes
f09 Cable diagram PCT loop function Properties of the associated PCT loop function. No Yes
f09 Cable diagram Connection part Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories'. Yes No
f09 Cable diagram Connection part (assignment: source) Properties of the nth part entered at the connection having the part assignment 'Part source'. Yes No
f09 Cable diagram Connection part (assignment: target) Properties of the nth part entered at the connection having the part assignment 'Part target'. Yes No
f09 Cable diagram Connection part reference Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories', that are editable at the connection. Yes No
f09 Cable diagram Connection part reference (assignment: source) Properties of the nth part entered at the connection having the part assignment 'Part source', that are editable at the connection. Yes No
f09 Cable diagram Connection part reference (assignment: target) Properties of the nth part entered at the connection having the part assignment 'Part target', that are editable at the connection. Yes No
f09 Cable diagram Pre-planning segment Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f09 Cable diagram Pre-planning segment Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f10 Cable overview Part (source) Properties of the nth part entered at the source device. Yes No
f10 Cable overview Part (target) Properties of the nth part entered at the target device. Yes No
f10 Cable overview Part reference (source) Properties of the nth part entered at the source device, that can be edited at the device. Yes No
f10 Cable overview Part reference (target) Properties of the nth part entered at the target device, that can be edited at the device. Yes No
f10 Cable overview Device (source) Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. Yes No
f10 Cable overview Device (target) Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. Yes No
f10 Cable overview Record General properties of records in the report, e.g. for entering a row number. No No
f10 Cable overview Cable Properties of the cable. No No
f10 Cable overview Cable part Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories'. Yes No
f10 Cable overview Cable part (assignment: source) Properties of the nth part entered at the cable having the part assignment 'Part source'. Yes No
f10 Cable overview Cable part (assignment: target) Properties of the nth part entered at the cable having the part assignment 'Part target'. Yes No
f10 Cable overview Cable part reference Properties of the nth part entered at the cable having the part assignments 'Main part' and 'Accessories', that are editable at the cable. Yes No
f10 Cable overview Cable part reference (assignment: source) Properties of the nth part entered at the cable having the part assignment 'Part source', that are editable at the cable. Yes No
f10 Cable overview Cable part reference (assignment: target) Properties of the nth part entered at the cable having the part assignment 'Part target', that are editable at the cable. Yes No
f10 Cable overview PCT loop Properties of the associated PCT loop. No No
f10 Cable overview PCT loop function Properties of the associated PCT loop function. No No
f10 Cable overview Pre-planning segment Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f10 Cable overview Pre-planning segment Properties of the segment that is assigned to the cable. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f11 Terminal-connection diagram Connected PLC connection point Properties of the PLC connection point that is connected to the terminal. No No
f11 Terminal-connection diagram Cable, external 'level (1-3)' Properties of the externally connected cable at the nth level. Yes No
f11 Terminal-connection diagram Cable, internal 'level (1-3)' Properties of the internally connected cable at the nth level. Yes No
f11 Terminal-connection diagram Terminal Properties of the terminal. No No
f11 Terminal-connection diagram Terminal connection point external Properties of the external terminal connection point. The properties are only output when the 'Connection point-specific output' form property is activated. A row is generated for every pair of connection points. Terminals with more than two connection points are automatically split across multiple rows. In addition, terminal connection points that are not connected are output. No No
f11 Terminal-connection diagram Terminal connection point internal Properties of the internal terminal connection point. The properties are only output when the 'Connection point-specific output' form property is activated. A row is generated for every pair of connection points. Terminals with more than two connection points are automatically split across multiple rows. In addition, terminal connection points that are not connected are output. No No
f11 Terminal-connection diagram Terminal parts Properties of the nth part entered at the terminal. Yes No
f11 Terminal-connection diagram Terminal part reference Properties of the nth part entered at the terminal that can be edited at the terminal. Yes No
f11 Terminal-connection diagram Terminal strip Properties of the terminal strip. No Yes
f11 Terminal-connection diagram Terminal strip parts Properties of the nth part entered at the terminal strip. Yes Yes
f11 Terminal-connection diagram Terminal strip part reference Properties of the nth part entered at the terminal strip that can be edited at the terminal strip. Yes Yes
f11 Terminal-connection diagram Last external target Properties of the last externally connected function found during target tracking. No No
f11 Terminal-connection diagram Last internal target Properties of the last internally connected function found during target tracking. No No
f11 Terminal-connection diagram PCT loop Properties of the associated PCT loop. No Yes
f11 Terminal-connection diagram PCT loop function Properties of the associated PCT loop function. No Yes
f11 Terminal-connection diagram Connection, external 'level (1-3)' Properties of the externally connected connection at the nth level. Yes No
f11 Terminal-connection diagram Connection, internal 'level (1-3)' Properties of the internally connected connection at the nth level. Yes No
f11 Terminal-connection diagram Pre-planning segment Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f11 Terminal-connection diagram Pre-planning segment Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f11 Terminal-connection diagram Target, external, connection point 'level (1-3)' Properties of the connection point of the externally connected function at the nth level. Yes No
f11 Terminal-connection diagram Target, external, counter-connection 'level (1-3)' Properties of the continuing connection point of the externally connected function at the nth level. Yes No
f11 Terminal-connection diagram Target, external 'level (1-3)' Properties of the externally connected function at the nth level. Yes No
f11 Terminal-connection diagram Target, internal, connection point 'level (1-3)' Properties of the connection point of the internally connected function at the nth level. Yes No
f11 Terminal-connection diagram Target, internal, counter-connection 'level (1-3)' Properties of the continuing connection point of the internally connected function at the nth level. Yes No
f11 Terminal-connection diagram Target, internal 'level (1-3)' Properties of the internally connected function at the nth level. Yes No
f12 Terminal line-up diagram Terminal Properties of the terminal. No No
f12 Terminal line-up diagram Terminal parts Properties of the nth part entered at the terminal. Yes No
f12 Terminal line-up diagram Terminal parts by product subgroups Properties of all parts entered at the terminal, sorted by product subgroup. Yes No
f12 Terminal line-up diagram Terminal part reference Properties of the nth part entered at the terminal that can be edited at the terminal. Yes No
f12 Terminal line-up diagram Terminal part reference by product subgroups Properties of all parts that are entered at the terminal and can be changed at the terminal, are sorted by product subgroup. Yes No
f12 Terminal line-up diagram Terminal strip Properties of the terminal strip. No Yes
f12 Terminal line-up diagram Terminal strip parts Properties of the nth part entered at the terminal strip. Yes Yes
f12 Terminal line-up diagram Terminal strip parts by product subgroups Properties of all parts entered at the terminal strip, sorted by product subgroup. Yes Yes
f12 Terminal line-up diagram Terminal strip part reference Properties of the nth part entered at the terminal strip that can be edited at the terminal strip. Yes Yes
f12 Terminal line-up diagram Terminal strip part reference by product subgroups Properties of all parts that are entered at the terminal strip and can be changed at the terminal strip, are sorted by product subgroup. Yes Yes
f12 Terminal line-up diagram PCT loop Properties of the associated PCT loop. No Yes
f12 Terminal line-up diagram PCT loop function Properties of the associated PCT loop function. No Yes
f12 Terminal line-up diagram Pre-planning segment Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f12 Terminal line-up diagram Pre-planning segment Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f13 Terminal diagram Connected PLC connection point Properties of the PLC connection point that is connected to the terminal. No No
f13 Terminal diagram Record General properties of records in the report, e.g. for entering a row number. No No
f13 Terminal diagram Main terminal Properties of the main terminal. No No
f13 Terminal diagram Main terminal part Properties of the nth part entered at the main terminal. Yes No
f13 Terminal diagram Main terminal part reference Properties of the nth part entered at the main terminal that can be edited at the terminal. Yes No
f13 Terminal diagram Cable chart data area external Properties of the nth externally connected connection for the data area of the cable chart. Yes No
f13 Terminal diagram Cable chart data area internal Properties of the nth internally connected connection for the data area of the cable chart. Yes No
f13 Terminal diagram Cable chart data area via connection point Properties of the nth connected connection for the data area of the cable chart, indexed by connection points. The index [n] indicates the connection point number of the terminal in the order in which the connection points are defined on the symbol. Yes No
f13 Terminal diagram Cable chart data area via form position Properties of the nth connected connection for the data area of the cable chart, indexed by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. Yes No
f13 Terminal diagram Cable chart header Properties of the nth connected connection for the header of the cable chart. To be used when the header has the same direction as the data area. No Yes
f13 Terminal diagram Cable chart header external Properties of the nth externally connected connection for the header of the cable chart. To be used when the header is rotated with regard to the data area. Yes Yes
f13 Terminal diagram Cable chart header external: Counter target Displays all externally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the terminal strip via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons.
The index is used to assign them to the placeholder element Cable chart data area external with the same index value. The different terminal targets are output using their index.
Yes Yes
f13 Terminal diagram Cable chart header internal Properties of the nth internally connected connection for the header of the cable chart. To be used when the header is rotated with regard to the data area. Yes Yes
f13 Terminal diagram Cable chart header internal: Counter target Properties of the nth internally connected counter target of the conductor. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the terminal strip via the conductor. In most cases, all conductors of a cable are connected to the same counter target. Yes Yes
f13 Terminal diagram Cable chart header via connection point Displays all internally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the terminal strip via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons.
The index is used to assign them to the placeholder element Cable chart data area internal with the same index value. The different terminal targets are output using their index.
Yes Yes
f13 Terminal diagram Cable chart header via form position Displays all internally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the terminal strip via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons.
The index is used to assign them to the placeholder element Cable chart data area internal with the same index value. The different terminal targets are output using their index.
Yes Yes
f13 Terminal diagram Cable chart header: Counter target Displays all connected counter targets of a cable for the header of the cable chart. The counter target is the device that is connected to the terminal strip via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons. No Yes
f13 Terminal diagram Terminal Properties of the terminal. No No
f13 Terminal diagram Terminal connection point external Properties of the external terminal connection point. The properties are only output when the 'Connection point-specific output' form property is activated. A row is generated for every pair of connection points. Terminals with more than two connection points are automatically split across multiple rows. In addition, terminal connection points that are not connected are output. No No
f13 Terminal diagram Terminal connection point internal Properties of the internal terminal connection point. The properties are only output when the 'Connection point-specific output' form property is activated. A row is generated for every pair of connection points. Terminals with more than two connection points are automatically split across multiple rows. In addition, terminal connection points that are not connected are output. No No
f13 Terminal diagram Terminal parts Properties of the nth part entered at the terminal. Yes No
f13 Terminal diagram Terminal part reference Properties of the nth part entered at the terminal that can be edited at the terminal. Yes No
f13 Terminal diagram Terminal strip Properties of the terminal strip. No Yes
f13 Terminal diagram Terminal strip parts Properties of the nth part entered at the terminal strip. Yes Yes
f13 Terminal diagram Terminal strip part reference Properties of the nth part entered at the terminal strip that can be edited at the terminal strip. Yes Yes
f13 Terminal diagram PCT loop Properties of the associated PCT loop. No Yes
f13 Terminal diagram PCT loop function Properties of the associated PCT loop function. No Yes
f13 Terminal diagram Connection / cable external Properties of the cable of the nth externally connected connection. Yes No
f13 Terminal diagram Connection / cable internal Properties of the cable of the nth internally connected connection. Yes No
f13 Terminal diagram Connection / cable via connection point Properties of the cable of the connection connected to the nth terminal connection point. The index [n] indicates the connection point number of the terminal in the order in which the connection points are defined on the symbol. Yes No
f13 Terminal diagram Connection / cable via form position Properties of the cable of the nth connected connection, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. Yes No
f13 Terminal diagram Connection, external Properties of the nth externally connected connection. Yes No
f13 Terminal diagram Connection, internal Properties of the nth internally connected connection. Yes No
f13 Terminal diagram Connection via connection point Properties of the connection connected to the nth terminal connection point. The index [n] indicates the connection point number of the terminal in the order in which the connection points are defined on the symbol. Yes No
f13 Terminal diagram Connection via form position Properties of the nth connected connection, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. Yes No
f13 Terminal diagram Pre-planning segment Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f13 Terminal diagram Pre-planning segment Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f13 Terminal diagram Target external Properties of the nth externally connected function. Yes No
f13 Terminal diagram Target internal Properties of the nth internally connected function. Yes No
f13 Terminal diagram Target via connection point Properties of the function connected to the nth terminal connection point. The index [n] indicates the connection point number of the terminal in the order in which the connection points are defined on the symbol. Yes No
f13 Terminal diagram Target via form position Properties of the nth connected function, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. Yes No
f14 Terminal-strip overview Record General properties of records in the report, e.g. for entering a row number. No No
f14 Terminal-strip overview Terminal strip Properties of the terminal strip. No No
f14 Terminal-strip overview Terminal strip parts Properties of the nth part entered at the terminal strip. Yes No
f14 Terminal-strip overview Terminal strip part reference Properties of the nth part entered at the terminal strip that can be edited at the terminal strip. Yes No
f14 Terminal-strip overview PCT loop Properties of the associated PCT loop. No No
f14 Terminal-strip overview PCT loop function Properties of the associated PCT loop function. No No
f14 Terminal-strip overview Pre-planning segment Properties of the segment that is assigned to the terminal strip definition / main terminal. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f14 Terminal-strip overview Target external Properties (DT) of the externally connected function(s). All different external targets of the terminal strip are output. No No
f14 Terminal-strip overview Target internal Properties (DT) of the internally connected function(s). All different internal targets of the terminal strip are output. No No
f15 Plot frame documentation Record General properties of records in the report, e.g. for entering a row number. No No
f15 Plot frame documentation Plot frame Properties of the plot frame. No No
f16 Potential overview Record General properties of records in the report, e.g. for entering a row number. No No
f16 Potential overview Potential Properties of the potential. No No
f17 Revision overview Record General properties of records in the report, e.g. for entering a row number. No No
f17 Revision overview Project Project properties contained in the revision. No No
f17 Revision overview Page Page properties contained in the revision. No No
f18 Enclosure legend 3D model view Properties of the 3D model view. No Yes
f18 Enclosure legend Part Properties of the part entered at a part placement. No No
f18 Enclosure legend Part placement Properties of the part placement. No No
f18 Enclosure legend Part reference Properties of the part that can be changed at the device, and calculated properties. No No
f18 Enclosure legend Device Properties of the main function at which the part of part placement is entered. No No
f18 Enclosure legend Record General properties of records in the report, e.g. for entering a row number. No No
f18 Enclosure legend Mounting panel Properties of the mounting panel. No Yes
f18 Enclosure legend Mounting panel part Properties of the nth part entered at the mounting panel. Yes Yes
f18 Enclosure legend Mounting panel part reference Properties of the nth part entered at the mounting panel that can be edited at the mounting panel. Yes Yes
f19 PLC diagram Connected sensor / actuator Properties of the sensor or actuator connected to the PLC connection point. No No
f19 PLC diagram Part Properties of the nth part entered at the PLC card. Yes Yes
f19 PLC diagram Part reference Properties of the nth part entered at the PLC card that can be edited at the PLC card. Yes Yes
f19 PLC diagram Record General properties of records in the report, e.g. for entering a row number. No No
f19 PLC diagram PCT loop Properties of the associated PCT loop. No No
f19 PLC diagram PCT loop (header) Properties of the associated PCT loop. To be used for the header area of the report. No Yes
f19 PLC diagram PCT loop function Properties of the associated PCT loop function. No No
f19 PLC diagram PCT loop function (header) Properties of the associated PCT loop function. To be used for the header area of the report. No Yes
f19 PLC diagram PLC connection point Properties of the PLC connection point. No No
f19 PLC diagram PLC card Properties of the PLC card. No Yes
f19 PLC diagram PLC card communication unit Properties of the nth communication unit of the PLC card. Yes Yes
f19 PLC diagram Connection Properties of the connected connections. Yes No
f19 PLC diagram Connection / cable Properties of the connected cable. Yes No
f19 PLC diagram Pre-planning segment Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f19 PLC diagram Pre-planning segment Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f19 PLC diagram Pre-planning segment (header) Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. To be used for the header area of the report. Yes Yes
f19 PLC diagram Pre-planning segment (header) Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. To be used for the header area of the report. Yes Yes
f19 PLC diagram Target Properties of the function connected to the nth PLC connection point. Yes No
f20 PLC card overview Connected sensor / actuator per connection point Properties of the sensor or actuator connected to the nth PLC connection point. Yes No
f20 PLC card overview Part Properties of the nth part entered at the PLC card. Yes No
f20 PLC card overview Part reference Properties of the nth part entered at the PLC card that can be edited at the PLC card. Yes No
f20 PLC card overview Record General properties of records in the report, e.g. for entering a row number. No No
f20 PLC card overview PCT loop Properties of the associated PCT loop. No No
f20 PLC card overview PCT loop function Properties of the associated PCT loop function. No No
f20 PLC card overview PLC connection point Properties of the PLC connection point. Yes No
f20 PLC card overview PLC card Properties of the PLC card. No No
f20 PLC card overview PLC card communication unit Properties of the nth communication unit of the PLC card. Yes No
f20 PLC card overview Pre-planning segment Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f20 PLC card overview Pre-planning segment Properties of the segment that is assigned to the PLC card. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f21 Pin-connection diagram Connected PLC connection point Properties of the PLC connection point that is connected to the pin. No No
f21 Pin-connection diagram Part Properties of the nth part entered at the plug. Yes Yes
f21 Pin-connection diagram Part reference Properties of the nth part entered at the plug that can be edited at the plug. Yes Yes
f21 Pin-connection diagram Cable, external 'level (1-3)' Properties of the externally connected cable at the nth level. Yes No
f21 Pin-connection diagram Cable, internal 'level (1-3)' Properties of the internally connected cable at the nth level. Yes No
f21 Pin-connection diagram Last external target Properties of the last externally connected function found during target tracking. No No
f21 Pin-connection diagram Last internal target Properties of the last internally connected function found during target tracking. No No
f21 Pin-connection diagram PCT loop Properties of the associated PCT loop. No Yes
f21 Pin-connection diagram PCT loop function Properties of the associated PCT loop function. No Yes
f21 Pin-connection diagram Plug Properties of the plug / plug definition. No Yes
f21 Pin-connection diagram Plug counterpiece Properties of the plug counterpart if male and female pins are represented separately, i.e. the properties of the assigned plug definition representing the receptacle or coupling. No Yes
f21 Pin-connection diagram Pin Properties of the pin. No No
f21 Pin-connection diagram Connection, external 'level (1-3)' Properties of the externally connected connection at the nth level. Yes No
f21 Pin-connection diagram Connection, internal 'level (1-3)' Properties of the internally connected connection at the nth level. Yes No
f21 Pin-connection diagram Pre-planning segment Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f21 Pin-connection diagram Pre-planning segment Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f21 Pin-connection diagram Target, external, connection point 'level (1-3)' Properties of the connection point of the externally connected function at the nth level. Yes No
f21 Pin-connection diagram Target, external, counter-connection 'level (1-3)' Properties of the continuing connection point of the externally connected function at the nth level. Yes No
f21 Pin-connection diagram Target, external 'level (1-3)' Properties of the externally connected function at the nth level. Yes No
f21 Pin-connection diagram Target, internal, connection point 'level (1-3)' Properties of the connection point of the internally connected function at the nth level. Yes No
f21 Pin-connection diagram Target, internal, counter-connection 'level (1-3)' Properties of the continuing connection point of the internally connected function at the nth level. Yes No
f21 Pin-connection diagram Target, internal 'level (1-3)' Properties of the internally connected function at the nth level. Yes No
f22 Plug diagram Connected PLC connection point Properties of the PLC connection point that is connected to the pin. No No
f22 Plug diagram Female pin end Properties of the female pin end of the plug / plug definition. No Yes
f22 Plug diagram Female pin end: Connected PLC connection point Properties of the PLC connection point that is connected to the pin on the female pin end. No No
f22 Plug diagram Female pin end: Cable chart data area Properties of the nth connection connected at the female pin end for the data area of the cable chart. Yes No
f22 Plug diagram Female pin end: Plug part Properties of the nth part entered on the female pin end of the plug. Yes Yes
f22 Plug diagram Female pin end: Plug part reference Properties of the nth part entered at the female pin end of the plug and that can be edited at the plug. Yes Yes
f22 Plug diagram Female pin end: Pin Properties of the pin at the female pin end. No No
f22 Plug diagram Female pin end: Pin part Properties of the nth part entered at the pin. The pin is located on the female pin end of the plug. Yes No
f22 Plug diagram Female pin end: Pin part reference Properties of the nth part entered at the pin, which can be edited at the pin. The pin is located on the female pin end of the plug. Yes No
f22 Plug diagram Female pin end: Connection Properties of the nth connection connected on the female pin end. Yes No
f22 Plug diagram Female pin end: Connection / cable Properties of the cable where the nth connection connected on the female pin end is located. Yes No
f22 Plug diagram Female pin end: Target Properties of the connection point of the nth function connected on the female pin end. Yes No
f22 Plug diagram Record General properties of records in the report, e.g. for entering a row number. No No
f22 Plug diagram Cable chart data area external Properties of the nth externally connected connection for the data area of the cable chart. Yes No
f22 Plug diagram Cable chart data area internal Properties of the nth internally connected connection for the data area of the cable chart. Yes No
f22 Plug diagram Cable chart data area via form position Properties of the nth connected connection for the data area of the cable chart, indexed by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. Yes No
f22 Plug diagram Cable chart header Properties of the nth connected connection for the header of the cable chart. To be used when the header has the same direction as the data area. No Yes
f22 Plug diagram Cable chart header external Properties of the nth externally connected connection for the header of the cable chart. To be used when the header is rotated with regard to the data area. Yes Yes
f22 Plug diagram Cable chart header external: Counter target Displays all externally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the plug via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons.
The index is used to assign them to the placeholder element Cable chart data area external with the same index value. The different pin targets are output using their index.
Yes Yes
f22 Plug diagram Cable chart header internal Properties of the nth internally connected connection for the header of the cable chart. To be used when the header is rotated with regard to the data area. Yes Yes
f22 Plug diagram Cable chart header internal: Counter target Displays all internally connected counter targets of the cable. To be used when the header is rotated with regard to the data area. The counter target is the device that is connected to the plug via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons.
The index is used to assign them to the placeholder element Cable chart data area internal with the same index value. The different pin targets are output using their index.
Yes Yes
f22 Plug diagram Cable chart header via form position Properties of the nth connected connection for the header of the cable chart, indexed by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. To be used when the header is rotated with regard to the data area. Yes Yes
f22 Plug diagram Cable chart header: Counter target Displays all connected counter targets of a cable for the header of the cable chart. The counter target is the device that is connected to the plug via the cable. In most cases, all conductors of a cable are connected to the same counter target. If several counter targets are connected to a cable, they are listed in the cable chart, separated by semicolons. No Yes
f22 Plug diagram PCT loop Properties of the associated PCT loop. No Yes
f22 Plug diagram PCT loop function Properties of the associated PCT loop function. No Yes
f22 Plug diagram Plug Properties of the plug / plug definition. No Yes
f22 Plug diagram Plug part Properties of the nth part entered at the plug. Yes Yes
f22 Plug diagram Plug part reference Properties of the nth part entered at the plug that can be edited at the plug. Yes Yes
f22 Plug diagram Pin Properties of the pin. No No
f22 Plug diagram Pin part Properties of the nth part entered at the pin. Yes No
f22 Plug diagram Pin part reference Properties of the nth part entered at the pin, which can be edited at the pin. Yes No
f22 Plug diagram Male pin end Properties of the nth part entered at the male pin end of the plug and that can be edited at the plug. No Yes
f22 Plug diagram Male pin end: Connected PLC connection point Properties of the connection connected on the male pin end for the conductor table. No No
f22 Plug diagram Male pin end: Cable chart data area Properties of the male pin end of the plug / plug definition. Yes No
f22 Plug diagram Male pin end: Plug part Properties of the PLC connection point that is connected to the pin on the male pin end. Yes Yes
f22 Plug diagram Male pin end: Plug part reference Properties of the nth part entered on the male pin end of the plug. Yes Yes
f22 Plug diagram Male pin end: Pin Properties of the pin at the male pin end. No No
f22 Plug diagram Male pin end: Pin part Properties of the nth part entered at the pin. The pin is located on the male pin end of the plug. Yes No
f22 Plug diagram Male pin end: Pin part reference Properties of the nth part entered at the pin, which can be edited at the pin. The pin is located on the male pin end of the plug. Yes No
f22 Plug diagram Male pin end: Connection Properties of the nth connection connected on the male pin end. Yes No
f22 Plug diagram Male pin end: Connection / cable Properties of the cable where the nth connection connected on the male pin end is located. Yes No
f22 Plug diagram Male pin end: Target Properties of the connection point of the nth function connected on the male pin end. Yes No
f22 Plug diagram Connection / cable external Properties of the nth externally connected cable. Yes No
f22 Plug diagram Connection / cable internal Properties of the nth internally connected cable. Yes No
f22 Plug diagram Connection / cable via form position Properties of the cable of the nth connected connection, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. Yes No
f22 Plug diagram Connection, external Properties of the nth externally connected connection. Yes No
f22 Plug diagram Connection, internal Properties of the nth internally connected connection. Yes No
f22 Plug diagram Connection via form position Properties of the nth connected connection, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. Yes No
f22 Plug diagram Pre-planning segment Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f22 Plug diagram Pre-planning segment Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes Yes
f22 Plug diagram Target external Properties of the nth externally connected function. Yes No
f22 Plug diagram Target internal Properties of the nth internally connected function. Yes No
f22 Plug diagram Target via form position Properties of the nth connected function, sorted by form position. Only certain targets can be reached via the form position. The form position defines the sequence of the targets in the reports. Yes No
f23 Plug overview Part Properties of the nth part entered at the plug. Yes No
f23 Plug overview Part reference Properties of the nth part entered at the plug that can be edited at the plug. Yes No
f23 Plug overview Record General properties of records in the report, e.g. for entering a row number. No No
f23 Plug overview PCT loop Properties of the associated PCT loop. No No
f23 Plug overview PCT loop function Properties of the associated PCT loop function. No No
f23 Plug overview Plug Properties of the plug / plug definition. No No
f23 Plug overview Plug counterpiece Properties of the plug counterpart if male and female pins are represented separately, i.e. the properties of the assigned plug definition (connected plug or connected receptacle / coupling). No No
f23 Plug overview Pre-planning segment Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f23 Plug overview Pre-planning segment Properties of the segment that is assigned to the plug definition. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f23 Plug overview Target external Properties (DT) of the externally connected function(s). All different external targets of the plug are output. No No
f23 Plug overview Target internal Properties (DT) of the internally connected function(s). All different internal targets of the plug are output. No No
f24 Structure identifier overview Higher-level function number Properties of the structure identifier for the identifier block 'Higher-level function number'. All structure identifiers for the identifier block 'Higher-level function number' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Installation site' or 'Location designation'. No No
f24 Structure identifier overview Installation site Properties of the structure identifier for the identifier block 'Installation site'. All structure identifiers for the identifier block 'Installation site' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Location designation'. No No
f24 Structure identifier overview User-defined structure Properties of the structure identifier for the identifier block 'User-defined structure'. All structure identifiers for the identifier block 'User-defined structure' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Location designation'. No No
f24 Structure identifier overview Record General properties of records in the report, e.g. for entering a row number. No No
f24 Structure identifier overview Document type Properties of the structure identifier for the identifier block 'Document type'. All structure identifiers for the identifier block 'Document type' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Location designation'. No No
f24 Structure identifier overview Functional assignment Properties of the structure identifier for the identifier block 'Functional assignment'. All structure identifiers for the identifier block 'Functional assignment' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Location designation'. No No
f24 Structure identifier overview Function designation Properties of the structure identifier for the 'Function designation' identifier block. All structure identifiers for the 'Function designation' identifier block are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Installation site' or 'Location designation'. No No
f24 Structure identifier overview Location designation Properties of the structure identifier for the 'Location designation' identifier block. All structure identifiers for the identifier block 'Location designation' are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Installation site'. No No
f24 Structure identifier overview Product Properties of the structure identifier for the 'Product aspect' identifier block. All structure identifiers for the 'Product aspect' identifier block are output consecutively in one column. At the same time, the form can contain columns for additional identifier blocks such as 'Function designation' or 'Location designation'. No No
f24 Structure identifier overview Structure identifier Properties of the structure identifier. All structure identifiers in the project for all identifier blocks are output consecutively in one column, that is, all function designations, location designations, installation sites, etc. Within a form, the placeholder text 'Structure identifier' must not be used in combination with the placeholder texts for the structure identifiers of the individual identifier blocks, e.g., 'Function designation' or 'Location designation'. No No
f25 Symbol overview Record General properties of records in the report, e.g. for entering a row number. No No
f25 Symbol overview Symbol Properties of the symbol. No No
f25 Symbol overview Symbol library Properties of the symbol library. No Yes
f25 Symbol overview Variants (all variants) Special properties of all symbol variants, or one of the symbol variants A to I (depending on the placeholder element selected). No No
f27 Connection List 3D part placement (source) Connection point properties of the 3D part placement, which represent the source of the connection. No No
f27 Connection List 3D part placement (target) Connection point properties of the 3D part placement, which represent the target of the connection. No No
f27 Connection List Device (source) Properties of the source device. For connections, the graphically first DT is always the source. No No
f27 Connection List Device (target) Properties of the target device. For connections, the graphically first DT is always the source. No No
f27 Connection List Record General properties of records in the report, e.g. for entering a row number. No No
f27 Connection List Cable Properties of the cable to which the connection is assigned. No No
f27 Connection List Wire harness Properties of the wire harness to which the connection is assigned. No No
f27 Connection List Wire harness part Properties of the first part entered at the wire harness. This is the part that represents the wire harness. No No
f27 Connection List Wire harness part reference Properties of the first part entered at the wire harness, that can be edited at the wire harness. No No
f27 Connection List Cable unit Properties of the cable unit to which the connection is assigned. No No
f27 Connection List Cable unit part Properties of the first part entered at the cable unit. This is the part that represents the cable unit. No No
f27 Connection List Cable unit part reference Properties of the first part entered at the cable unit that can be edited at the cable unit. No No
f27 Connection List Connection Properties of the connection. No No
f27 Connection List Connection part Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories'. Yes No
f27 Connection List Connection part (assignment: source) Properties of the nth part entered at the connection having the part assignment 'Part source'. Yes No
f27 Connection List Connection part (assignment: target) Properties of the nth part entered at the connection having the part assignment 'Part target'. Yes No
f27 Connection List Connection part reference Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories', that are editable at the connection. Yes No
f27 Connection List Connection part reference (assignment: source) Properties of the nth part entered at the connection having the part assignment 'Part source', that are editable at the connection. Yes No
f27 Connection List Connection part reference (assignment: target) Properties of the nth part entered at the connection having the part assignment 'Part target', that are editable at the connection. Yes No
f29 Project options overview Record General properties of records in the report, e.g. for entering a row number. No No
f29 Project options overview Placeholder object Properties of the placeholder object in the project option section. Yes No
f29 Project options overview Project option Project option properties. No No
f29 Project options overview Project option section Properties of the project option section. Yes No
f30 Placeholder object overview Device Properties of all functions in the placeholder object that can be variably assigned (always with dynamic line adjustment: a line is output for each variable assignment). No No
f30 Placeholder object overview Record General properties of records in the report, e.g. for entering a row number. No No
f30 Placeholder object overview Placeholder object Properties of the placeholder object. No No
f30 Placeholder object overview Page Properties of the page where the placeholder object is placed. No No
f30 Placeholder object overview Value set table Placeholder object data for the value set table.
The property Value set name outputs the names of the value sets in indexed format.
The property Result from value set outputs the content of the value sets in indexed format. For each value set, all possible assignments to the function properties are output (i.e., all possible values that can take the property of the function through an assignment of the value set are output).
The property Placeholder format outputs all variable assignments entered in the placeholder object (i.e., the entries from the Variable column on the Assignment tab in the Placeholder object dialog).
No No
f31 Manufacturer / supplier list Record General properties of records in the report, e.g. for entering a row number. No No
f31 Manufacturer / supplier list Manufacturer / supplier Manufacturer and supplier properties. No No
f32 Mounting list Part Properties of the nth part entered at the device. To be used for the data area of the report. No No
f32 Mounting list Part (header) Properties of the nth part entered at the device. To be used for the header area of the report. No Yes
f32 Mounting list Part placement Properties of the part placement for the data area of the report. If there are several part placements for a part, the properties of the different representation types are combined. No No
f32 Mounting list Part placement (header) Properties of the part placement for the header area of the report. If there are several part placements for a part, the properties of the different representation types are combined. No Yes
f32 Mounting list Part reference Properties of the nth part entered at the device, that can be edited at the device. To be used for the data area of the report. No No
f32 Mounting list Part reference (header) Properties of the nth part entered at the device, that can be edited at the device. To be used for the header area of the report. No Yes
f32 Mounting list Device Properties of the device including the device tag. To be used for the data area of the report. No No
f32 Mounting list Device (header) Properties of the device including the device tag. To be used for the header area of the report. No Yes
f32 Mounting list Record General properties of records in the report, e.g. for entering a row number. No No
f34 Topology: Routing path list Part (source) Properties of the nth part entered at the source device. Yes No
f34 Topology: Routing path list Part (target) Properties of the nth part entered at the target device. Yes No
f34 Topology: Routing path list Part reference (source) Properties of the nth part entered at the source device, that can be edited at the device. Yes No
f34 Topology: Routing path list Part reference (target) Properties of the nth part entered at the target device, that can be edited at the device. Yes No
f34 Topology: Routing path list Device (source) Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. No No
f34 Topology: Routing path list Device (target) Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. No No
f34 Topology: Routing path list Record General properties of records in the report, e.g. for entering a row number. No No
f34 Topology: Routing path list Routing path (topology) Properties of the routing path. No No
f34 Topology: Routing path list Routing path part (topology) Properties of the nth part entered at the routing path. Yes No
f34 Topology: Routing path list Routing path part reference (topology) Properties of the nth part entered at the routing path that are changeable at the routing path. Yes No
f35 Topology: Routing path diagram Device (source) Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. Yes No
f35 Topology: Routing path diagram Device (target) Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. Yes No
f35 Topology: Routing path diagram Cable / connection Properties of the cable or connection. No No
f35 Topology: Routing path diagram Cable / Connection part Properties of the nth part entered at the cable or connection having the part assignments 'Main part' and 'Accessories'. Yes No
f35 Topology: Routing path diagram Cable / Connection part (assignment: source) Properties of the nth part entered at the cable or connection having the part assignment 'Parts source'. Yes No
f35 Topology: Routing path diagram Cable / Connection part (assignment: target) Properties of the nth part entered at the cable or connection having the part assignment 'Parts target'. Yes No
f35 Topology: Routing path diagram Cable / Connection part reference Properties of the nth part entered at the cable or connection having the part assignments 'Main part' and 'Accessories', which are changeable at the cable / connection. Yes No
f35 Topology: Routing path diagram Cable / Connection part reference (assignment: source) Properties of the nth part entered at the cable or connection having the part assignment 'Parts source', which are changeable at the cable / connection. Yes No
f35 Topology: Routing path diagram Cable / Connection part reference (assignment: target) Properties of the nth part entered at the cable or connection having the part assignment 'Parts target', which are changeable at the cable / connection. Yes No
f35 Topology: Routing path diagram Routing path (topology) Properties of the routing path. No Yes
f35 Topology: Routing path diagram Routing path part (topology) Properties of the nth part entered at the routing path. Yes Yes
f35 Topology: Routing path diagram Routing path part reference (topology) Properties of the nth part entered at the routing path that are changeable at the routing path. Yes Yes
f36 Topology: Routed cables / connections Part (source) Properties of the nth part entered at the source device. Yes No
f36 Topology: Routed cables / connections Part (target) Properties of the nth part entered at the target device. Yes No
f36 Topology: Routed cables / connections Part reference (source) Properties of the nth part entered at the source device, that can be edited at the device. Yes No
f36 Topology: Routed cables / connections Part reference (target) Properties of the nth part entered at the target device, that can be edited at the device. Yes No
f36 Topology: Routed cables / connections Device (source) Properties of the source device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. Yes No
f36 Topology: Routed cables / connections Device (target) Properties of the target device. Source and target of the cable are determined according to particular rules from the properties of the conductors contained by the cable. Yes No
f36 Topology: Routed cables / connections Cable / connection Properties of the cable or connection. No No
f36 Topology: Routed cables / connections Cable / Connection part Properties of the nth part entered at the cable or connection having the part assignments 'Main part' and 'Accessories'. Yes No
f36 Topology: Routed cables / connections Cable / Connection part (assignment: source) Properties of the nth part entered at the cable or connection having the part assignment 'Parts source'. Yes No
f36 Topology: Routed cables / connections Cable / Connection part (assignment: target) Properties of the nth part entered at the cable or connection having the part assignment 'Parts target'. Yes No
f36 Topology: Routed cables / connections Cable / Connection part reference Properties of the nth part entered at the cable or connection having the part assignments 'Main part' and 'Accessories', which are changeable at the cable / connection. Yes No
f36 Topology: Routed cables / connections Cable / Connection part reference (assignment: source) Properties of the nth part entered at the cable or connection having the part assignment 'Parts source', which are changeable at the cable / connection. Yes No
f36 Topology: Routed cables / connections Cable / Connection part reference (assignment: target) Properties of the nth part entered at the cable or connection having the part assignment 'Parts target', which are changeable at the cable / connection. Yes No
f37 P&I diagram: Piping overview Device Properties of all the functions contained in the piping. Yes No
f37 P&I diagram: Piping overview Device (source) Properties of the source device. The source and target of a defined piping are determined in accordance with the same rules as at connections. Yes No
f37 P&I diagram: Piping overview Device (target) Properties of the target device. The source and target of a defined piping are determined in accordance with the same rules as at connections. Yes No
f37 P&I diagram: Piping overview Record General properties of records in the report, e.g. for entering a row number. No No
f37 P&I diagram: Piping overview PCT loop Properties of the associated PCT loop. No No
f37 P&I diagram: Piping overview PCT loop Properties of the associated PCT loop. No No
f37 P&I diagram: Piping overview PCT loop function Properties of the associated PCT loop function. No No
f37 P&I diagram: Piping overview Pipe class Properties of the pipe class. No No
f37 P&I diagram: Piping overview Piping Properties of the piping. No No
f37 P&I diagram: Piping overview Piping planning object Properties of the piping planning object. No No
f37 P&I diagram: Piping overview Substance Properties of the substance. No No
f38 Pre-planning: Structure segment overview Record General properties of records in the report, e.g. for entering a row number. No No
f38 Pre-planning: Structure segment overview Placement pre-planning Properties of the placement of the structure segment in the pre-planning, for example the page name. No No
f38 Pre-planning: Structure segment overview Page Properties of the nth page that is assigned to the structure segment. Yes No
f38 Pre-planning: Structure segment overview Structure segment Properties of the structure segment. No No
f38 Pre-planning: Structure segment overview Structure segment hierarchical Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). Yes No
f38 Pre-planning: Structure segment overview Structure segment hierarchical Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). Yes No
f38 Pre-planning: Structure segment overview Linked with superior segments Properties of the segment below which the n-th link is inserted. Yes No
f38 Pre-planning: Structure segment overview Linked segments Properties of the n-th linked segment. Yes No
f39 Pre-planning: Structure segment plan Part Properties of the nth part entered at the subordinate planning object. Yes No
f39 Pre-planning: Structure segment plan Part reference Properties of the nth part entered at the subordinate planning object, that can be edited at the planning object. Yes No
f39 Pre-planning: Structure segment plan Device Properties of the device that the subordinate planning object is assigned to. No No
f39 Pre-planning: Structure segment plan Record General properties of records in the report, e.g. for entering a row number. No No
f39 Pre-planning: Structure segment plan Function Properties of the nth function that is assigned to the subordinate planning object. Yes No
f39 Pre-planning: Structure segment plan Placement P&I diagram Properties of the n-th placement (in accordance with the graphical order) of the structure segment in the P&I diagram, for example the page name. Yes No
f39 Pre-planning: Structure segment plan Placement pre-planning Properties of the placement of the structure segment in the pre-planning, for example the page name. No No
f39 Pre-planning: Structure segment plan Placement pre-planning (header) Properties of the placement of the structure segment in the pre-planning, for example the page name. To be used for the header area of the report. No Yes
f39 Pre-planning: Structure segment plan Page Properties of the nth page that is assigned to the structure segment. Yes Yes
f39 Pre-planning: Structure segment plan PLC addresses Properties of the nth PLC address that is assigned to the subordinate planning object. Yes No
f39 Pre-planning: Structure segment plan Structure segment (header) Properties of the structure segment. To be used for the header area of the report. No Yes
f39 Pre-planning: Structure segment plan Structure segment / Planning object Properties of the subordinate structure segment or planning object. To be used for the data area of the report. No No
f39 Pre-planning: Structure segment plan Structure segment hierarchical Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). Yes Yes
f39 Pre-planning: Structure segment plan Structure segment hierarchical Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). Yes Yes
f39 Pre-planning: Structure segment plan Linked with superior segments Properties of the segment below which the n-th link is inserted. Yes Yes
f39 Pre-planning: Structure segment plan Linked segments Properties of the n-th linked segment. Yes Yes
f40 Pre-planning: Planning object overview Part Properties of the nth part entered at the planning object. Yes No
f40 Pre-planning: Planning object overview Part reference Properties of the nth part entered at the planning object, that can be edited at the planning object. Yes No
f40 Pre-planning: Planning object overview Device Properties of the device that is assigned to the planning object. No No
f40 Pre-planning: Planning object overview Record General properties of records in the report, e.g. for entering a row number. No No
f40 Pre-planning: Planning object overview Function Properties of the nth function that is assigned to the planning object. Yes No
f40 Pre-planning: Planning object overview Planning object Properties of the planning object. No No
f40 Pre-planning: Planning object overview Placement P&I diagram Properties of the n-th placement (in accordance with the graphical order) of the planning object in the P&I diagram, for example the page name. Yes No
f40 Pre-planning: Planning object overview Placement pre-planning Properties of the placement of the planning object in the pre-planning, for example the page name. No No
f40 Pre-planning: Planning object overview PCT loop Properties of the associated PCT loop. No No
f40 Pre-planning: Planning object overview PCT loop function Properties of the associated PCT loop function. No No
f40 Pre-planning: Planning object overview Source segment Properties of the segment that is the source of the connection planning object. No No
f40 Pre-planning: Planning object overview Pipe class Properties of the pipe class. No No
f40 Pre-planning: Planning object overview Piping definition Properties of the piping definition. Yes No
f40 Pre-planning: Planning object overview Piping planning object Properties of the piping planning object. Yes No
f40 Pre-planning: Planning object overview Page Properties of the nth page that is assigned to the planning object. Yes No
f40 Pre-planning: Planning object overview PLC addresses Properties of the nth PLC address that is assigned to the planning object. Yes No
f40 Pre-planning: Planning object overview Substance Properties of the substance. No No
f40 Pre-planning: Planning object overview Structure segment hierarchical Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). Yes No
f40 Pre-planning: Planning object overview Structure segment hierarchical Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). Yes No
f40 Pre-planning: Planning object overview Superior segment Properties of the superior segment. No No
f40 Pre-planning: Planning object overview Superior segment Properties of the superior segment. No No
f40 Pre-planning: Planning object overview Superior structure segment Properties of the superior structure segment. No No
f40 Pre-planning: Planning object overview Subordinate segment Properties of the nth subordinate planning object. Yes No
f40 Pre-planning: Planning object overview Subordinate segment Properties of the nth subordinate planning object. Yes No
f40 Pre-planning: Planning object overview Linked with superior segments Properties of the segment below which the n-th link is inserted. Yes No
f40 Pre-planning: Planning object overview Linked segments Properties of the n-th linked segment. Yes No
f40 Pre-planning: Planning object overview Target segment Properties of the segment that is the target of the connection planning object. No No
f41 Pre-planning: Planning object plan Part Properties of the nth part entered at the planning object. Yes No
f41 Pre-planning: Planning object plan Part (header) Properties of the nth part entered at the planning object. To be used for the header area of the report. Yes Yes
f41 Pre-planning: Planning object plan Part reference Properties of the nth part entered at the planning object, that can be edited at the planning object. To be used for the data area of the report. Yes No
f41 Pre-planning: Planning object plan Part reference (header) Properties of the nth part entered at the planning object, that can be edited at the planning object. To be used for the header area of the report. Yes Yes
f41 Pre-planning: Planning object plan Device Properties of the device that is assigned to the planning object, including device tag. To be used for the data area of the report. No No
f41 Pre-planning: Planning object plan Device (header) Properties of the device that is assigned to the planning object, including device tag. To be used for the header area of the report. No Yes
f41 Pre-planning: Planning object plan Record General properties of records in the report, e.g. for entering a row number. No No
f41 Pre-planning: Planning object plan Function Properties of the nth function that is assigned to the planning object. To be used for the data area of the report. Yes No
f41 Pre-planning: Planning object plan Function (header) Properties of the nth function that is assigned to the planning object. To be used for the header area of the report. Yes Yes
f41 Pre-planning: Planning object plan Planning object Properties of the planning object. To be used for the data area of the report. No No
f41 Pre-planning: Planning object plan Planning object (header) Properties of the planning object. To be used for the header area of the report. No Yes
f41 Pre-planning: Planning object plan Placement P&I diagram Properties of the n-th placement (in accordance with the graphical order) of the planning object in the P&I diagram, for example the page name. Yes No
f41 Pre-planning: Planning object plan Placement P&I diagram (header) Properties of the n-th placement (in accordance with the graphical order) of the planning object in the P&I diagram, for example the page name. To be used for the header area of the report. Yes Yes
f41 Pre-planning: Planning object plan Placement pre-planning Properties of the placement of the planning object in the pre-planning, for example the page name. No No
f41 Pre-planning: Planning object plan Placement pre-planning (header) Properties of the placement of the planning object in the pre-planning, for example the page name. To be used for the header area of the report. No Yes
f41 Pre-planning: Planning object plan PCT loop (header) Properties of the associated PCT loop. To be used for the header area of the report. No Yes
f41 Pre-planning: Planning object plan PCT loop function (header) Properties of the associated PCT loop function. To be used for the header area of the report. No Yes
f41 Pre-planning: Planning object plan Source segment Properties of the segment that is the source of the connection planning object. To be used for the data area of the report. No No
f41 Pre-planning: Planning object plan Source segment (header) Properties of the segment that is the source of the connection planning object. To be used for the data area of the report. No Yes
f41 Pre-planning: Planning object plan Pipe class (header) Properties of the pipe class selected at the planning object. To be used for the header area of the report. No Yes
f41 Pre-planning: Planning object plan Piping definition Properties of the piping definition. Yes No
f41 Pre-planning: Planning object plan Piping definition (header) Properties of the piping definition. To be used for the header area of the report. Yes Yes
f41 Pre-planning: Planning object plan Piping planning object Properties of the piping planning object. To be used for the data area of the report. Yes No
f41 Pre-planning: Planning object plan Piping planning object (header) Properties of the piping planning object. To be used for the header area of the report. Yes Yes
f41 Pre-planning: Planning object plan Page Properties of the nth page that is assigned to the planning object. Yes Yes
f41 Pre-planning: Planning object plan PLC addresses Properties of the nth PLC address that is assigned to the planning object. To be used for the data area of the report. Yes No
f41 Pre-planning: Planning object plan PLC addresses (header) Properties of the nth PLC address that is assigned to the planning object. To be used for the header area of the report. Yes Yes
f41 Pre-planning: Planning object plan Substance (header) Properties of the substance selected at the planning object. To be used for the header area of the report. No Yes
f41 Pre-planning: Planning object plan Structure segment hierarchical Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). Yes Yes
f41 Pre-planning: Planning object plan Structure segment hierarchical Properties of the superior segment on the nth structure level on the tree view of the pre-planning navigator. The structure levels are determined starting from the highest structure level (this corresponds to the project). Yes Yes
f41 Pre-planning: Planning object plan Superior segment (header) Properties of the superior segment. To be used for the header area of the report. No Yes
f41 Pre-planning: Planning object plan Linked with superior segments Properties of the segment below which the n-th link is inserted. Yes Yes
f41 Pre-planning: Planning object plan Linked segments Properties of the n-th linked segment. Yes Yes
f41 Pre-planning: Planning object plan Target segment Properties of the segment that is the target of the connection planning object. To be used for the data area of the report. No No
f41 Pre-planning: Planning object plan Target segment (header) Properties of the segment that is the target of the connection planning object. To be used for the data area of the report. No Yes
f42 Pre-planning: Segment template overview Part Properties of the nth part entered at the segment template. Yes No
f42 Pre-planning: Segment template overview Record General properties of records in the report, e.g. for entering a row number. No No
f42 Pre-planning: Segment template overview Segment template Properties of the segment template. No No
f43 Pre-planning: Segment template plan Part Properties of the nth part entered at the segment template. To be used for the header area of the report. Yes Yes
f43 Pre-planning: Segment template plan Part reference Properties of the nth part entered at the segment template that are changeable at the segment template. To be used for the data area of the report. Yes No
f43 Pre-planning: Segment template plan Device Properties of the device that is assigned to the subordinate planning object, including device tag. No No
f43 Pre-planning: Segment template plan Record General properties of records in the report, e.g. for entering a row number. No No
f43 Pre-planning: Segment template plan Function Properties of the nth function that is assigned to the subordinate planning object. Yes No
f43 Pre-planning: Segment template plan Planning object Properties of the subordinate planning object. No No
f43 Pre-planning: Segment template plan Segment template Properties of the segment template. To be used for the header area of the report. No Yes
f43 Pre-planning: Segment template plan PLC addresses Properties of the nth PLC address that is assigned to the segment template. Yes No
f44 Assembly/Module Overview Part Properties of the part within the assembly. To be used for the data area of the report. No No
f44 Assembly/Module Overview Part (header) Properties of the assembly. To be used for the header area of the report. No Yes
f44 Assembly/Module Overview Part reference Properties of the part within the assembly that can be changed at the function / segment. To be used for the data area of the report. No No
f44 Assembly/Module Overview Part reference (header) Properties of the assembly that can be changed at the function / segment. To be used for the header area of the report. No Yes
f44 Assembly/Module Overview Record General properties of records in the report, e.g. for entering a row number. No No
f45 Distributed device list Part Properties of the nth part entered at the device. Yes Yes
f45 Distributed device list Part reference Properties of the nth part entered at the device, that can be edited at the device. Yes Yes
f45 Distributed device list Device tag Structure identifiers, components of the device tag. No Yes
f45 Distributed device list Record General properties of records in the report, e.g. for entering a row number. No No
f45 Distributed device list Function Properties of the function. No No
f46 Conduit / line plan Part Properties of the nth part entered at the conduit / line having the part assignments 'Main part' and 'Accessories'. Yes Yes
f46 Conduit / line plan Part reference Properties of the nth part entered at the conduit / line having the part assignments 'Main part' and 'Accessories', that are editable at the conduit / line . Yes Yes
f46 Conduit / line plan Device (source) Properties of the source device. Source and target of the conduit are determined according to particular rules from the properties of the connections contained by the conduit. No No
f46 Conduit / line plan Device (target) Properties of the target device. Source and target of the conduit are determined according to particular rules from the properties of the connections contained by the conduit. No No
f46 Conduit / line plan Record General properties of records in the report, e.g. for entering a row number. No No
f46 Conduit / line plan Conduit / line Properties of the conduit or line. No Yes
f46 Conduit / line plan PCT loop Properties of the associated PCT loop. No Yes
f46 Conduit / line plan PCT loop function Properties of the associated PCT loop function. No Yes
f46 Conduit / line plan Connection Properties of the connections in the conduit / line. No No
f46 Conduit / line plan Connection part Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories'. Yes No
f46 Conduit / line plan Connection part reference Properties of the nth part entered at the connection having the part assignments 'Main part' and 'Accessories', that are editable at the connection. Yes No
f46 Conduit / line plan Pre-planning segment Properties of the nth segment that is assigned to the conduit / line. Yes Yes
f46 Conduit / line plan Pre-planning segment Properties of the nth segment that is assigned to the conduit / line. Yes Yes
f47 Cut-out legend 3D model view Properties of the 2D drilling view in which the cut-out is located. No Yes
f47 Cut-out legend Record General properties of records in the report, e.g. for entering a row number. No No
f47 Cut-out legend Cut-out Properties of the cut-out. No No
f48 PLC address overview Record General properties of records in the report, e.g. for entering a row number. No No
f48 PLC address overview PCT loop Properties of the associated PCT loop. No No
f48 PLC address overview PCT loop function Properties of the associated PCT loop function. No No
f48 PLC address overview PLC addresses Properties that are entered for a PLC address in the assignment list row. No No
f48 PLC address overview PLC connection point Properties of the nth PLC connection point that the PLC address is assigned to. Yes No
f48 PLC address overview Pre-planning segment Properties of the segment that the PLC address is assigned to. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f48 PLC address overview Pre-planning segment Properties of the segment that the PLC address is assigned to. The directly assigned segment is addressed through the Index [1]. As of Index [2] the superior segments (in accordance with the tree structure in the pre-planning navigator) are addressed. Yes No
f49 Preplanning: Pipe class overview Record General properties of records in the report, e.g. for entering a row number. No No
f49 Preplanning: Pipe class overview Pipe class Properties of the pipe class. No No
f51 Preplanning: Substance overview Record General properties of records in the report, e.g. for entering a row number. No No