This functionality is only available for certain module packages. Info / Copyright

P003007: Multiple cable targets

Cause

You have numbered a cable that has more than one cable target. When doing this, the "According to source and target" numbering format is selected, which outputs the device tag of the target as a counter in the device tag of the cable, e.g., -W(=ANL+EBO-X5/=ANL+EBO-H3). A conflict occurs because more than one cable target exists but only one target designation can be output.

Note:

You reach the "According to source and target" numbering setting as follows:

Select the cable in the schematic.

Select the menu items Project data > Cables > Numbering.

Click [...] next to the Settings field of the Number cables dialog.

In the Settings: Cable numbering dialog, open the Format drop-down list.

Solution

Assign only one cable target to the cable. Then number the cable anew using the "According to source and target" format.

Note: