Cause
The bus ID is missing at the bus port <x> that is assigned to the bus system <y>.
This check run only checks bus ports at which a configuration project is entered.
Solution
- Locate bus port in the schematic using the Go to (graphic) functionality that is provided by the popup menu of the Message management dialog.
- Open the property dialog of the bus port.
- Bring the Bus data tab to the front.
- Enter the missing bus ID in the Physical network: Bus ID / item number field.
- Or activate the property Ignore missing bus ID, if the bus port does not require a bus ID.
- Then start a new check run.
Notes:
- This check run only reports a missing bus ID if one of the following function definitions is set at the bus port:
- Network / bus cable connection point, general
- Network / bus cable connection point, source
- Network / bus cable connection point, input.
Only main bus ports are checked. Bus ports where a value is entered at the Bus interface: Name property and where the check box of the property Bus interface: Main bus port is deactivated are not reported. - Please also note the following:
In the case of bus ports the Plug designation and the Bus interface name are used for identification in addition to the connection point designation. A check is carried out whether this combination (Connection point designation + Plug designation + Bus interface name) is identical. If at least one of these partial designations shows a difference, the message is not output.