This functionality is only available for certain module packages. Info / Copyright

P005089: Connection definition point lies on a bundle

Cause

A connection definition point or a cable definition line was inserted on a bundle drawn in the schematic.

Solution

  1. Locate the connection definition point or the cable definition line in the schematic using the Go to (graphic) function from the popup menu in the Message management dialog.
  2. Delete the connection definition point or the cable definition line from the bundle.
  3. Then start a new check run.

Note:

We recommend that you insert connection definition points or cable definition lines as far as possible on multi-line connections entering or exiting on the bundle in order to obtain unique connection information in the reports, for example in the cable diagram.