Cause
The total diameter of all routing connections that are to be bundled using the placed cable / tubing protection or cable / tubing tie is smaller than the minimum bundle diameter of the cable / tubing protection or cable / tubing tie used.
Solution
- Locate the cable / tubing protection or cable / tubing tie in the layout space using the Go to (graphic) function from the popup menu in the Message management dialog.
- Call the property dialog of the cable / tubing protection or cable / tubing tie, and bring to front the Part tab.
- Via the parts used, navigate to the part selection, and bring to front the Routing accessories data tab.
- Check at the part used the value set in the Minimum bundle diameter field.
- Select a cable / tubing protection or cable / tubing tie whose minimum bundle diameter is smaller than the total diameter of all routing connections in the bundle.
- Close the part selection and property dialog by clicking [OK], and then start a new check run.