Action corresponds to numbering functionality

Parameter Description

TYPE

Type of task to be performed by the action
DEVICES: Renumber devices.
PAGES: Renumber pages.
TERMINALS: Renumbering terminals
CABLES: Renumbering cables
CONNECTIONS: Renumbering connections

PROJECTNAME

Project name with full path.Optional.
If not entered, the selected project is used when the action is called from GUI (like from a script or ribbon bar). 
If called from the windows command line, PROJECTNAME must be set or the   must be used first, otherwise an  exception is thrown.
This parameter is only effective with the following values of the TYPE parameter:DEVICES, PAGES, TERMINALS, CABLES, CONNECTIONS.

USESELECTION

Optional. If this flag is set, only the objects currently selected in GUI will be renumbered instead of all objects in the project.
Possible values: '0' - No (default), '1' - Yes.
This parameter is only effective with the following values of the TYPE parameter:DEVICES, PAGES, TERMINALS, CABLES, CONNECTIONS.

CONFIGSCHEME

Name of the renumbering scheme. Optional.
If not specified, the last used scheme will be selected again.
This parameter is only effective with the following values of the TYPE parameter:DEVICES, TERMINALS, CABLES, CONNECTIONS.

STARTVALUE

Start value. Integer. Optional. If not specified, 1 is taken by default.
This parameter is only effective with the following values of the TYPE parameter:DEVICES, PAGES, TERMINALS, CABLES.

STEPVALUE

Increment value. Integer. Optional. If not specified, 1 is taken by default.
This parameter is only effective with the following values of the TYPE parameter:DEVICES, PAGES, TERMINALS, CABLES.

POSTNUMERATE

Optional. If this flag is set, only invalid device tags (i.e. those containing '?' character) will be renumbered.
Possible values: '0' - No, '1' - Yes (default).
This parameter is only effective with the following values of the TYPE parameter:DEVICES, TERMINALS.

ALSONUMERATEDBYPLC

Optional. If this flag is set, device tags which are influenced by PLC numbering will be numerated.
Possible values: '0' - No (default), '1' - Yes.
This parameter is only effective with the following values of the TYPE parameter:DEVICES, TERMINALS.

PERMITSORTCHANGE

Optional. Permit sort change.
Possible values: '0' - No (default), '1' - Yes.
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

FILLGAPS

Optional. Fill Gaps.
Possible values: '0' - No (default), '1' - Yes.
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

IDENTIFIER

Identifier, e.g. 'X*'. Optional. 
If used, all devices from the project matching the identifier are taken for renumeration regardless of whether the 'USESELECTION' parameter is used or not.
This parameter is only effective with the following values of the TYPE parameter:DEVICES.

NUMERATECABLES

Optional. If this flag is set, cables whose device tags contain source and target information are also numerated.
Possible values: '0' - No (default), '1' - Yes.
This parameter is only effective with the following values of the TYPE parameter:DEVICES.

STRUCTUREORIENTED

Set this parameter to true to provide numbering per structure identifier.
If false, then pages are continuously number without accounting for the structure identifiers.
This parameter is only effective with the following values of the TYPE parameter:PAGES.

KEEPINTERVAL

In combination with the definition of the start page, this parameter retains the increments between the selected pages for the target pages.
In this way you can move any desired number of selected pages by a specified increment.
Entering the increment size is not possible in this case. 
This parameter is only effective with the following values of the TYPE parameter:PAGES.

KEEPTEXT

Set this to 1, if the alphabetic part of the page name should not be overwritten.
This parameter is only effective with the following values of the TYPE parameter:PAGES.

SUBPAGES

Values are:
0 = Retain: Existing subpages are adopted unchanged into the target page.
1 = ConsecutiveNumbering: Existing subpages are renumbered using the starting value "1" and an increment of "1".
        At every change of the main page, the subpage numbering begins again from "1".
        The subpage numbering follows the project settings defined in the project setting "Characters for subpages".
2 = ConvertIntoMainPages: Subpages are converted to main pages and renumbered.
This parameter is only effective with the following values of the TYPE parameter:PAGES.

PREFIX

Prefix.
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

SUFFIX

Suffix.
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

SEQUENCE

Mode to use for numbering. Values are:
0 = Like sorting:The terminal / pin sorting sequence displayed under Terminal strips - (Project name) or Plugs - (Project name) is used. 
Select this option if you would like to number existing terminals / pins but retain the existing sorting.
1 = Page oriented
2 = Cable oriented
3 = Level oriented
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

EXTENT

Parameter to define the scope of numbering. Values are:
0 = Selected - only the selected terminals or pins will be numbered.
1 = All selected terminal strips - all terminals of the same strip as selected terminal will be numbered.
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

POTENTIAL_N

Parameter to determine how N terminals will be treated during numbering. Values are:
0 = Ignore
1 = Do not modify, include in sequence. PE, N or SH terminals are not modified during numbering but are taken into account when numbering the other terminals.
        This means that the designations of the other terminals are assigned as though the PE, N or SH terminals were being included in the numbering.
2 = Renumber
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

POTENTIAL_PE

Parameter to determine how PE terminals will be treated during numbering. Values are:
0 = Ignore
1 = Do not modify, include in sequence. PE, N or SH terminals are not modified during numbering but are taken into account when numbering the other terminals.
        This means that the designations of the other terminals are assigned as though the PE, N or SH terminals were being included in the numbering.
2 = Renumber
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

POTENTIAL_SH

Parameter to determine how SH terminals will be treated during numbering. Values are:
0 = Ignore
1 = Do not modify, include in sequence. PE, N or SH terminals are not modified during numbering but are taken into account when numbering the other terminals.
        This means that the designations of the other terminals are assigned as though the PE, N or SH terminals were being included in the numbering.
2 = Renumber
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

MULTIPLETERMINALS

Also renumber multi path terminals.Values are:
0 = Don't modify - terminals with the property "Allow same designations" are ignored during numbering
1 = Number same - terminals with the same designation with the "Allow same designations" property are given the same number
2 = Number individually - terminals with the "Allow same designations" property are each given their own number.
        Therefore, multiple terminals which had the same number before numbering will have different numbers after numbering
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

KEEPALPHA

Keep alphabetical elements of the terminal number. Values are:
0 = Dont modify - terminals or pins with alphabetical elements in the designation are ignored during numbering.
1 = Keep alphabetical elements - the alphabetical elements of the terminal or pin designation are retained. The first numeric elements are renumbered. If the designation only has alphabetical elements, the old designation is attached to the new numbering. Sequential terminals with different counters but the same numerical component receive the same numerical component in the counter even after the numbering. 
2 = Number - all terminals / pins are renumbered. In doing so, the old designation is overwritten
This parameter is only effective with the following values of the TYPE parameter:TERMINALS.

KEEPEXISTING

Overwrite mode. If set to 1, already existing cable names will not be changed.
This parameter is only effective with the following values of the TYPE parameter:CABLES.

STARTVALUE_n

Start value. Where n is a connection group number (1,2,3...).
This parameter is only effective with the following values of the TYPE parameter:CONNECTIONS.

STEPVALUE_n

Step value. Where n is a connection group number (1,2,3...).
This parameter is only effective with the following values of the TYPE parameter:CONNECTIONS.

GROUP_n

Group parameter. Where n is a connection group number (1,2,3...).
This parameter is only effective with the following values of the TYPE parameter:CONNECTIONS.

OVERWRITE

Overwrite mode. Values are:
0 = All (always overwrite)
1 = ExceptManuals (overwrite all except those, which are marked as 'manually set') 
2 = None (never overwrite)
This parameter is only effective with the following values of the TYPE parameter:CONNECTIONS.

AVOIDIDENTICALDESIGNATIONS

Values are:
0 = In entire project
1 = In the selection
2 = None
3 = Per counter reset range (structure/page)
This parameter is only effective with the following values of the TYPE parameter:CONNECTIONS.

VISIBILITY

Visiblity. Values are:
0 = All visible
1 = Do not modify
2 = Once per page and range
This parameter is only effective with the following values of the TYPE parameter:CONNECTIONS.

MARKASMANUAL

Mark as 'manually set'. This parameter is only effective with the following values of the TYPE parameter:CONNECTIONS.

Example
Numbering devices

renumber /TYPE:DEVICES /STARTVALUE:1 /STEPVALUE:1 /USESELECTION:0 /OMITNUMERATEDBYPLC:0 /NUMERATECABLES:0 /IDENTIFIER:X* /CONFIGSCHEME:\"Kennbuchstabe Zähler\" /POSTNUMERATE:0
renumber /TYPE:DEVICES /IDENTIFIER:V /POSTNUMERATE:0 /ALSONUMERATEDBYPLC:1 /NUMERATECABLES:1 /STARTVALUE:100 /STEPVALUE:5 /USESELECTION:1       

Numbering pages

renumber /TYPE:PAGES /STRUCTUREORIENTED:0 /STARTVALUE:3 /STEPVALUE:10 /KEEPINTERVAL:1 /KEEPTEXT:0 /SUBPAGES:1 /USESELECTION:0

Numbering cables

renumber /CONFIGSCHEME:Standard /TYPE:CABLES /STARTVALUE:7 /STEPVALUE:7 /USESELECTION:1 /KEEPEXISTING:1
renumber /TYPE:CABLES /STARTVALUE:999 /USESELECTION:0

Numbering connections

renumber /TYPE:CONNECTIONS /CONFIGSCHEME:Verbindungsorientiert /STARTVALUE_1:1 /STEPVALUE_1:1 /OVERWRITE:1 /AVOIDIDENTICALDESIGNATIONS:1 /VISIBILITY:1 /MARKASMANUAL:0 /USESELECTION:1 /GROUP_1:1
renumber /TYPE:CONNECTIONS /CONFIGSCHEME: Potenzialorientiert /STARTVALUE_1:13 /STEPVALUE_1:3 /OVERWRITE:0 /AVOIDIDENTICALDESIGNATIONS:0 /VISIBILITY:1 /MARKASMANUAL:1 /USESELECTION:0 /GROUP_1:1

Numbering terminals:

renumber /TYPE:TERMINALS /CONFIGSCHEME:Numerisch /SEQUENCE:1 /POTENTIAL_N:1 /POTENTIAL_PE:2 /POTENTIAL_SH:2 /POSTNUMERATE:0 /ALSONUMERATEDBYPLC:1 /MULTIPLETERMINALS:1 /KEEPALPHA:0 /STARTVALUE:1 /STEPVALUE:1 /PREFIX:p_ /SUFFIX:_s /USESELECTION:1