Software and hardware requirements until end of 2025
Common
General requirements
Microsoft .NET framework
Further information and the current version of this Microsoft component are available for download from the Microsoft website.
The following Microsoft .NET framework is required to operate the Eplan platform:
| Eplan Electric P81, Eplan Fluid1, Eplan Pro Panel, Eplan Harness proD, Eplan Cable proD | ||||
|---|---|---|---|---|
| Version | Up to 2.8 | 2.9 up to 2023 | As of 2024 | |
|
.NET Framework |
4.8.1 | X | ||
| 4.7.2 | X | |||
| 4.5.2 | X | |||
1 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
Note
When switching to .NET Framework 4.8.1 as of Eplan Platform Version 2024 and Eplan Harness proD Version 2024
- Existing offline API programs can no longer be run directly with Eplan Platform 2024. They have be recompiled once with the .NET Framework 4.8.1.
- API add-ins should not be compiled - this means that they remain executable in the Eplan Platform version in which they were created and in all newer versions of the Eplan Platform.
An API program adapted in this way can be run with Eplan Platform 2024 and with the older Eplan Platform versions 2.9, 2023 and 2022.
API add-ins compiled with the .NET Framework 4.8.1 are only executable in the Eplan Platform Version 2024 and higher.
Workstation
The computer platform is a PC with an Intel Core i5, i7, i9 or compatible processor.
| Recommended workstation configuration | |
|---|---|
| CPU | Multicore processor based on x64 architecture like Intel i5, i7, i9 or compatible with the instruction set AVX2 |
| RAM | 16 GB |
| Harddrive | 500 GB |
| GPU | AMD or NVIDIA with the latest Direct3D driver (comparable graphics performance as a RTX 3050 board with at least 4GB VRAM) |
| Monitor / graphics solution |
2-screen solution with a resolution of at least 1920 x 1080, recommended 2560 x 1440 |
Note
Please do not use Microsoft OneDrive (or similar systems) as storage systems for multi-user work with Eplan products. This can damage your Eplan projects.
The usage of a CPU with the instruction set AVX2 is required to run the Eplan Platform 2024 and higher.
- Hardware components such as the processor used are also checked for compatibility when Eplan starts. An error message could indicate hardware at this point in which processors with instruction sets unsuitable for Eplan are still installed. These are usually processors that are older than approx. 10 years.
- If Eplan is also to be executable on virtual computers, the two processor options "CompatibilityForOlderOperatingSystemsEnabled" and "CompatibilityForMigrationEnabled" have to be deactivated when Hyper-V is used.
WebView2 Runtime
WebView2 Runtime from Microsoft is required to run the Eplan Platform 2024 and higher.
- A check is carried out when Eplan is started. An error message could indicate the missing installation of WebView2 Runtime at this point.
As a rule WebView2 Runtime is already installed as part of the operating system.
Operating systems
Windows 11 Pro, Enterprise
Version 25H2
| Build | KB article | Available | Eplan Product Version | ||||
|---|---|---|---|---|---|---|---|
| 2022 | 2023 | 2024 | 2025 | 2026 | |||
| 26200.6899 | KB5066835 | 14 October 2025 | X | X | X | X | |
Version 24H2
| Build | KB article | Available | Eplan Product Version | ||||
|---|---|---|---|---|---|---|---|
| 2022 | 2023 | 2024 | 2025 | 2026 | |||
| 26100.6899 | KB5066835 | 14 October 2025 | X | X | X | X | |
| 26100.6584 | KB5065426 | 09 September 2025 | X | X | X | X | |
| 26100.4946 | KB5063878 | 12 August 2025 | X | X | X | X | |
| 26100.4652 | KB5062553 | 08 July 2025 | X | X | X | X | |
| 26100.4349 | KB5060842 | 10 June 2025 | X | X | X | X | |
| 26100.4061 | KB5058411 | 13 May 2025 | X | X | X | X | |
| 26100.3775 | KB5055523 | 8 April 2025 | X | X | X | X | |
| 26100.3476 | KB5053598 | 11 March 2025 | X | X | X | X | |
| 26100.3194 | KB5051987 | 11 February 2025 | X | X | X | X | |
| 26100.2894 | KB5050009 | 14 January 2025 | X | X | X | X | |
| 26100.2605 | KB5048667 | 10 December 2024 | X | X | X | X | |
| 26100.2314 | KB5046617 | 12 November 2024 | X | X | X | X | |
| 26100.2033 | KB5044284 | 8 October 2024 | X | X | X | X | |
Version 23H2
| Build | KB article | Available | Eplan Product Version | ||||
|---|---|---|---|---|---|---|---|
| 2022 | 2023 | 2024 | 2025 | 2026 | |||
| 22631.6060 | KB5066793 | 14 October 2025 | X | X | X | X | |
| 22631.5909 | KB5065431 | 09 September 2025 | X | X | X | X | |
| 22631.5768 | KB5063875 | 12 August 2025 | X | X | X | X | |
| 22631.5624 | KB5062552 | 08 July 2025 | X | X | X | X | |
| 22631.5472 | KB5060999 | 10 June 2025 | X | X | X | X | |
| 22631.5335 | KB5058405 | 13 May 2025 | X | X | X | X | |
| 22631.5191 | KB5055528 | 8 April 2025 | X | X | X | X | |
| 22631.5039 | KB5053602 | 11 March 2025 | X | X | X | X | |
| 22631.4890 | KB5051989 | 11 February 2025 | X | X | X | X | |
| 22631.4751 | KB5050021s | 14 January 2025 | X | X | X | X | |
| 22631.4602 | KB5048685s | 10 December 2024 | X | X | X | X | |
| 22631.4460 | KB5046633s | 12 November 2024 | X | X | X | X | |
| 22631.4317 | KB5044285 | 8 October 2024 | X | X | X | X | |
| 22631.4169 | KB5043076 | 10 September 2024 | X | X | X | X | |
| 22631.4037 | KB5041585 | 13 August 2024 | X | X | X | ||
| 22631.3880 | KB5040442s | 9 July 2024 | X | X | X | ||
| 22631.3737 | KB5039212s | 11 June 2024 | X | X | X | ||
| 22631.3593 | KB5037771 | 14 May 2024 | X | X | X | ||
| 22631.3447 | KB5036893 | 9 April 2024 | X | X | X | ||
| 22631.3296 | KB5035853 | 12 March 2024 | X | X | X | ||
| 22631.3155 | KB5034765 | 13 February 2024 | X | X | X | ||
| 22631.3007 | KB5034123 | 9 January 2024 | X | X | X | ||
Version 22H2
| Build | KB article | Available | Eplan Product Version | ||||
|---|---|---|---|---|---|---|---|
| 2022 | 2023 | 2024 | 2025 | 2026 | |||
| End of service | |||||||
| 22621.6060 | KB5066793 | 14 October 2025 | X | X | X | X | |
| 22621.5909 | KB5065431 | 09 September 2025 | X | X | X | X | |
| 22621.5768 | KB5063875 | 12 August 2025 | X | X | X | X | |
| 22621.5624 | KB5062552 | 08 July 2025 | X | X | X | X | |
| 22621.5472 | KB5060999 | 10 June 2025 | X | X | X | X | |
| 22621.5335 | KB5058405 | 13 May 2025 | X | X | X | X | |
| 22621.5191 | KB5055528 | 8 April 2025 | X | X | X | X | |
| 22621.5039 | KB5053602 | 11 March 2025 | X | X | X | X | |
| 22621.4890 | KB5051989 | 11 February 2025 | X | X | X | X | |
| 22621.4751 | KB5050021s | 14 January 2025 | X | X | X | X | |
| 22621.4602 | KB5048685s | 10 December 2024 | X | X | X | X | |
| 22621.4460 | KB5046633s | 12 November 2024 | X | X | X | X | |
| 22621.4317 | KB5044285 | 8 October 2024 | X | X | X | X | |
| 22621.4169 | KB5043076 | 10 September 2024 | X | X | X | X | |
| 22621.4037 | KB5041585 | 13 August 2024 | X | X | X | ||
| 22621.3880 | KB5040442s | 9 July 2024 | X | X | X | ||
| 22621.3737 | KB5039212s | 11 June 2024 | X | X | X | ||
| 22621.3593 | KB5037771 | 14 May 2024 | X | X | X | ||
| 22621.3447 | KB5036893 | 9 April 2024 | X | X | X | ||
| 22621.3296 | KB5035853 | 12 March 2024 | X | X | X | ||
| 22621.3155 | KB5034765 | 13 February 2024 | X | X | X | ||
| 22621.3007 | KB5034123 | 9 January 2024 | X | X | X | ||
Version 21H2
| Build | KB article | Available | Eplan Product Version | |||
|---|---|---|---|---|---|---|
| 2022 | 2023 | 2024 | 2025 | |||
| End of service | ||||||
| 22000.3260 | KB5044280 | 8 October 2024 | X | X | X | X |
| 22000.3197 | KB5043067 | 10 September 2024 | X | X | X | X |
| 22000.3147 | KB5041592 | 13 August 2024 | X | X | X | X |
| 22000.3260 | KB5044280 | 8 October 2024 | X | X | X | X |
| 22000.3197 | KB5043067 | 10 September 2024 | X | X | X | X |
| 22000.3147 | KB5041592 | 13 August 2024 | X | X | X | X |
| 22000.3079 | KB5040431 | 9 July 2024 | X | X | X | X |
| 22000.3019 | KB5039213 | 11 June 2024 | X | X | X | X |
| 22000.2960 | KB5037770 | 14 May 2024 | X | X | X | X |
| 22000.2899 | KB5036894 | 9 April 2024 | X | X | X | X |
| 22000.2836 | KB5035854 | 12 March 2024 | X | X | X | X |
| 22000.2777 | KB5034766 | 13 February 2024 | X | X | X | X |
| 22000.2713 | KB5034121 | 9 January 2024 | X | X | X | X |
Note
Approval of the patches:
Due to changes in the Windows DCOM server security settings, problems may occur when using an Eplan network license in conjunction with cross-domain use or the possibility to operate a failover. The changes will be implemented via the security updates from Microsoft. This does not affect the use of a local license. Please update to the latest Eplan License Client and License Manager.
The latest version can be found on our web pages:
https://www.eplan-software.com/services/downloads/
Further information about the implementation of the Windows DCOM Server Security Feature:
https://support.microsoft.com/en-us/topic/kb5004442-manage-changes-for-windows-dcom-server-security-feature-bypass-cve-2021-26414-f1400b52-c141-43d2-941e-37ed901c769c
https://msrc.microsoft.com/update-guide/vulnerability/CVE-2021-26414
Windows 10 Pro, Enterprise
Version 22H2, 21H2
| Build | KB article | Available | Eplan Product Version | |||
|---|---|---|---|---|---|---|
| 2022 | 2023 | 2024 | 2025 | |||
| End of service | ||||||
| 1904x.6456 | KB5066791 | 14 October 2025 | X | X | X | X |
| 1904x.6332 | KB5065429 | 09 September 2025 | X | X | X | X |
| 1904x.6216 | KB5063709 | 12 August 2025 | X | X | X | X |
| 1904x.6093 | KB5062554 | 08 July 2025 | X | X | X | X |
| 1904x.5965 | KB5060533 | 10 June 2025 | X | X | X | X |
| 1904x.5854 | KB5058379 | 13 May 2025 | X | X | X | X |
| 1904x.5737 | KB5055518 | 8 April 2025 | X | X | X | X |
| 1904x.5608 | KB5053606 | 11 March 2025 | X | X | X | X |
| 1904x.5487 | KB5051974 | 11 February 2025 | X | X | X | X |
| 1904x.5371 | KB5049981s | 14 January 2025 | X | X | X | X |
| 1904x.5247 | KB5048652s | 10 December 2024 | X | X | X | X |
| 1904x.5131 | KB5046613s | 12 November 2024 | X | X | X | X |
| 1904x.5011 | KB5044273 | 8 October 2024 | X | X | X | X |
| 1904x.4894 | KB5043064 | 10 September 2024 | X | X | X | X |
| 1904x.4780 | KB5041580 | 13 August 2024 | X | X | X | X |
| 1904x.4651 | KB5040427s | 9 July 2024 | X | X | X | X |
| 1904x.4529 | KB5039211s | 11 June 2024 | X | X | X | X |
| 1904x.4412 | KB5037768 | 14 May 2024 | X | X | X | X |
| 1904x.4291 | KB5036892 | 9 April 2024 | X | X | X | X |
| 1904x.4170 | KB5035845 | 12 March 2024 | X | X | X | X |
| 1904x.4046 | KB5034763 | 13 February 2024 | X | X | X | X |
| 1904x.3930 | KB5034122 | 9 January 2024 | X | X | X | X |
Note
Approval of the patches:
Due to changes in the Windows DCOM server security settings, problems may occur when using an Eplan network license in conjunction with cross-domain use or the possibility to operate a failover. The changes will be implemented via the security updates from Microsoft. This does not affect the use of a local license. Please update to the latest Eplan License Client and License Manager.
The latest version can be found on our web pages:
https://www.eplan-software.com/services/downloads/
Further information about the implementation of the Windows DCOM Server Security Feature:
https://support.microsoft.com/en-us/topic/kb5004442-manage-changes-for-windows-dcom-server-security-feature-bypass-cve-2021-26414-f1400b52-c141-43d2-941e-37ed901c769c
https://msrc.microsoft.com/update-guide/vulnerability/CVE-2021-26414
General Release Notes for versions of Windows
- Microsoft Windows 11 update history and lifecycle
- Microsoft Windows 10 update history and lifecycle
- Microsoft End of service statement
Microsoft Windows 11 Pro, Enterprise version 25H2
https://support.microsoft.com/en-us/topic/windows-11-version-25h2-update-history-99c7f493-df2a-4832-bd2d-6706baa0dec0
Microsoft Windows 11 Pro, Enterprise version 24H2
https://support.microsoft.com/en-us/topic/windows-11-version-24h2-update-history-0929c747-1815-4543-8461-0160d16f15e5
Microsoft Windows 11 Pro, Enterprise version 23H2
https://support.microsoft.com/en-us/topic/windows-11-version-23h2-update-history-59875222-b990-4bd9-932f-91a5954de434
Microsoft Windows 11 Pro, Enterprise version 22H2
https://support.microsoft.com/en-us/topic/windows-11-version-22h2-update-history-ec4229c3-9c5f-4e75-9d6d-9025ab70fcce
Microsoft Windows 11 Pro, Enterprise version 21H2
https://learn.microsoft.com/en-us/lifecycle/products/windows-11-enterprise-and-education
https://learn.microsoft.com/en-US/lifecycle/products/windows-11-home-and-pro
Microsoft Windows 10 Pro, Enterprise version 22H2
https://support.microsoft.com/en-us/topic/windows-10-update-history-8127c2c6-6edf-4fdf-8b9f-0f7be1ef3562
Microsoft Windows 10 Pro, Enterprise version 21H2
https://support.microsoft.com/en-us/topic/windows-10-update-history-857b8ccb-71e4-49e5-b3f6-7073197d98fb
https://learn.microsoft.com/en-US/lifecycle/products/windows-10-enterprise-and-education
https://learn.microsoft.com/en-US/lifecycle/products/windows-10-home-and-pro
Windows 10 version 21H2 and 21H1 share a common core operating system and an identical set of system files. As a result, the release notes for Windows 10 version 21H2 and 21H1 will share an update history page. This versions has the identical updates.
https://support.microsoft.com/en-us/topic/end-of-service-statement-e440a698-de79-4ace-b53b-5a6a3e36685e
Tip
To display the build number of a Windows 10 version, open the Windows-specific Run dialog (e.g. via the [Windows] + [R] shortcut keys) and enter the winver command there. After confirmation of the entry a dialog with information about the operating system is opened, including the build number.
Microsoft SQL Server 64-bit
| Eplan Electric P84, Eplan Fluid4, Eplan Pro Panel, Eplan Preplaning, Eplan Engineering Configuration, Eplan Harness proD, Eplan Cable proD |
||||||
|---|---|---|---|---|---|---|
| Version | 2022 |
2023 |
2024 |
2025 |
2026 |
|
| Microsoft SQL Server |
2022 CU21 | X | X | X | X | |
| 2019 CU32 | X | X | X | X | X | |
| 2017 CU31 | X | X | X | X | ||
| 2016 SP3 CU1 | ||||||
Tip
Updates of the SQL Servers can be found on the Internet pages from Microsoft.
https://docs.microsoft.com/en-US/sql/database-engine/install-windows/latest-updates-for-microsoft-sql-server
1 The Eplan parts management requires the 'SQL Server 2012 Native Client' driver for the connection to an SQL server.
The current version of this driver for downloading can be found on the Internet pages of the Microsoft Download Center.
https://www.microsoft.com/en-US/download/details.aspx?id=50402
We additionally support the operation of 'SQL Server on Azure virtual computers'.
2 The Eplan parts management requires Microsoft ODBC driver 17 for SQL Server.
https://learn.microsoft.com/en-us/sql/connect/odbc/download-odbc-driver-for-sql-server?view=sql-server-ver16#version-17
3 Starting with Eplan 2026, you can choose between ODBC versions 17 and 18.
4 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
Eplan Plattform
Microsoft Office interface
Version 2023 / Version 2024 / Version 2025 / Version 2026
For the operation of the Eplan Platform 2023 / 2024 / 2025 / 2026 an installation / use of the Office products is no longer necessary. Any Office product (compatible to MS Office) can be used to process exported data in Excel format.
Server and virtualized environment
Note
Windows Server Core variants are not supported.
| Eplan Electric P82, Eplan Fluid2, Eplan Pro Panel, Eplan Preplaning, Eplan Engineering Configuration | ||||||
|---|---|---|---|---|---|---|
| Version | 2022 | 2023 | 2024 | 2025 | 2026 | |
| Microsoft Windows Server | 2025 | X | X | |||
| Microsoft Windows Server | 2022 | X | X | X | X | X |
| Microsoft Windows Server | 2019 | X | X | X1 | X1 | |
| Microsoft Windows Server | 2016 | X | X | X1 | X1 | |
| Citrix XenServer | 8.4 LTSR | X | X | X | ||
| Citrix Virtual Apps and Desktops 7 | 2402 LTSR | X | X | X | X | |
1 Can only be used for the Eplan License Manager and for project/master data storage.
2 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
Virtualized environment
Microsoft Azure
During the operation of the Eplan Platform in a virtualized environment a limitation / deviation of the functionality or a different system behavior (e.g. performance) can occur due to the system.
This behavior can usually be compensated for by a corresponding system configuration in Azure or by the connections of the end devices.
Eplan Cloud products in connection with the on-premises products of the Eplan Platform
The Eplan Cloud products can be used in combination with the on-premises products Eplan Electric P8, Eplan Fluid2, Eplan Pro Panel, and Eplan Preplanning depending on their versions:
| Eplan Cloud Product | ||||||
|---|---|---|---|---|---|---|
| Version | eView1 | eView AR | eManage1 | eBuild | eStock | |
|
Eplan Electric P82, Eplan Fluid2, Eplan Pro Panel, Eplan Preplaning |
2026 | X | X | X | X | X |
| 2025 | X | X | X | X | X | |
| 2024 | X | X | X | X | X | |
| 2023 | X | X | X | X | X | |
| 2022 | X | X | X | X | ||
1 Unlimited use of all functions is possible for projects up to approx. 10,000 pages (with average data/filling quantity).
2 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
In the case of older versions of the Eplan Platform (2022 to 2024), usage in connection with the specified Eplan Cloud products is not guaranteed. Please use the current versions of the Eplan Platform here.
Note
Eplan Cloud products are tested with the Chrome and Edge browser.
Eplan products in connection with the Phoenix Contact products
The Phoenix Contact products can be used in combination with the on-premises products Eplan Electric P8 and Eplan Pro Panel depending on their versions:
| Phoenix CLIPX ENGINEER (web version) | Phoenix MARKING SYSTEM | ||
|---|---|---|---|
| Version | 2.3 | 1.1 | |
|
Eplan Electric P8, Eplan Pro Panel |
2025 | X | X |
| 2024 | X | X | |
| 2023 | X | X | |
| 2022 | X | X |
Eplan Engineering Configuration
Eplan products
| Eplan Engineering Configuration | ||||||
|---|---|---|---|---|---|---|
| Version | 2022 | 2023 | 2024 | 2025 | 2026 | |
|
Eplan Electric P81, Eplan Fluid1, |
2026 | X | ||||
| 2025 | X | X | ||||
| 2024 | X | X | ||||
| 2023 | X | X | ||||
| 2022 | X | X | ||||
1 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
Eclipse development environment
Plugin developers require Eclipse and the corresponding JRE or JDK.
| Eplan Engineering Configuration | ||||||
|---|---|---|---|---|---|---|
| Version | 2022 | 2023 | 2024 | 2025 | 2026 | |
|
Eclipse Platform Eclipse Temurin JRE |
4.33 (2024-09) 17.0.14 |
X | ||||
|
Eclipse Platform Eclipse Temurin JRE |
4.30 (2023-12) 17.0.9 |
X | ||||
|
Eclipse Platform Eclipse Temurin JRE |
4.26 (2022-12) 17.0.6 |
X | ||||
|
Eclipse Platform AdoptOpenJDK |
4.21 (2021-09) 14.0.2 |
X | ||||
|
Eclipse Platform AdoptOpenJDK |
4.16 (2020-06) 14.0.2 |
X | ||||
Microsoft Office products
Running EEC with the OFFICE Word discipline requires the installation of either Microsoft Office Professional Plus 2016 or Microsoft Office Professional Plus 2019.
PLC systems
Running EEC with the PLC discipline requires the installation of one of the following PLC systems:
- Siemens SIMATIC Manager
- CoDeSys systems V3
- CoDeSys systems V21
- AutomationWorX
The version statuses of the third-party systems are to be inquired in as far as they are not specified.
1 The CoDeSys version V2 supports the formats "Structured Text" and "STL" only.
Apache Tomcat Server for Web EEC Server
| Web EEC Server | ||||||
|---|---|---|---|---|---|---|
| Version | 2022 | 2023 | 2024 | 2025 | 2026 | |
| Apache Tomcat Server | 11.0.7 | X | ||||
| 10.1.41 | X | |||||
| 10.1.40 | X | |||||
| 10.1.24 | X | |||||
| 10.1.11 | X | X | ||||
| 9.0.105 | X | |||||
| 9.0.89 | X | |||||
| 9.0.78 | X | |||||
| 9.0.64 | X | |||||
| 9.0.48 | X | |||||
Note
Please note the requirements for compatibility with the Java Runtime Environment (JRE) and the Java Development Kit (JDK):
https://tomcat.apache.org/whichversion.html
Eplan Harness proD / Eplan Cable proD
| Eplan Harness proD / Eplan Cable proD | |||||||
|---|---|---|---|---|---|---|---|
| Version | 2022 | 2023 | 2023 SP1 | 2024 | 2025 | 2026 | |
|
Eplan Electric P82, Eplan Fluid2, Eplan Pro Panel, Eplan Preplaning |
2026 | X1 | |||||
| 2025 | X1 | ||||||
| 2024 | X | ||||||
| 2023 | X | X | |||||
| 2022 | X | ||||||
1 Cable proD since version 2025.
2 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
All of the following runtime environment software
- Microsoft DirectX 11.0
- Microsoft Visual C++ 2015-2022 Redistributable Package
Note
Eplan Harness proD / Eplan Cable proD Setup should detect and install any missing runtime environment software.
Note
For an optimal user experience we recommend the use of a dedicated graphics card with at least 4 GB VRAM and a computer system with at least 16 GB RAM and a CPU not older than 3 years.
Eplan Smart Production1 / Eplan Smart Wiring
The following table provides information on which Eplan Smart Wiring Version is compatible with which Eplan Platform Version with regard to the import of manufacturing data via the Eplan EPDZ interface:
| Eplan Smart Wiring | Eplan Smart Production1 | ||||||
|---|---|---|---|---|---|---|---|
| Version | 2022 | 2023 | 2023 | 2024 | 2025 | 2026 | |
|
Eplan Pro Panel, Eplan Preplaning, Eplan Electric P82, Eplan Fluid2 |
2026 | X | X | X | X | ||
| 2025 | X | X | X | X | |||
| 2024 | X | X | X | X | |||
| 2023 | X | X | X (min. Update 1) | X (min. Update 1) | X | X | |
| 2022 | X | X | |||||
1 As of Version 2026 Eplan Smart Production Collection is Eplan Smart Production.
2 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
Microsoft Windows Server environment 64-bit
| Eplan Smart Wiring | Eplan Smart Production1 | ||||||
|---|---|---|---|---|---|---|---|
| Version | 2022 | 2023 | 2023 | 2024 | 2025 | 2026 | |
| Microsoft Windows Server | 2025 | X | |||||
| 2022 | X | X | X | X | X | ||
| 2019 | X | X | X | X | X | X2 | |
| 2016 | X | X | X | X | |||
1 As of Version 2026 Eplan Smart Production Collection is Eplan Smart Production.
2 The prerequisite is the installation of .Net Framework version 4.8 on the server.
Note
To run Eplan Smart Wiring and Eplan Smart Production please install the newest Eplan License Client.
Eplan Smart Wiring and Eplan Smart Production are tested with the Chrome and Edge browser.
To run Eplan Smart Wiring and Eplan Smart Production on a mobile device at least 8 GB RAM and a current GPU are recommended.
Read more
Workstation
| Recommended workstation configuration | |
|---|---|
| CPU | Multicore processor based on x64 architecture like Intel i5, i7, i9 or compatible with the instruction set AVX2 |
| RAM | 16 GB |
| Harddrive | 500 GB |
| GPU | AMD or NVIDIA with the latest Direct3D driver (comparable graphics performance as a RTX 3050 board with at least 4GB VRAM) |
| Monitor / graphics solution |
2-screen solution with a resolution of at least 1920 x 1080, recommended 2560 x 1440 |
Workstation/server for shared data
| Recommended workstation/server for shared data | |
|---|---|
| CPU | Multicore processor based on x64 architecture like Intel i5, i7, i9 or compatible with the instruction set AVX2 |
| RAM | 8 GB |
| Harddrive | 500 GB |
Eplan ERP/PDM Integration Suite
ERP/PDM Integration Suite
| Eplan ERP/PDM Integration Suite | ||||||
|---|---|---|---|---|---|---|
| Version | 2022 | 2023 | 2024 | 2025 | 2026 | |
|
Eplan Electric P83, Eplan Fluid3, Eplan Pro Panel, Eplan Preplaning, Eplan Harness proD |
2026 | X | ||||
| 2025 | X2 | |||||
| 2024 | X1 | |||||
| 2023 | X | |||||
| 2022 | X | |||||
1 Please use the update of service pack 2 for Eplan Harness proD.
2 Please use the update of Eplan ERP/PDM Integration Suite 2024 Update 2 for Harness proD.
3 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
Siemens Teamcenter Connector
| Siemens Teamcenter / EDA Gateway | |||||||
|---|---|---|---|---|---|---|---|
| Version | 14.2 / 6.2 | 14.3 / 6.3 | 2312 | 2406 | 2412 | 2506 | |
|
Eplan Electric P81, Eplan Fluid1, Eplan Pro Panel, Eplan Preplaning, Eplan Harness proD |
2026 | X | X | X | X | ||
| 2025 | X | X | X | X | X | X | |
| 2024 | X | X | X | X | X | X | |
| 2023 | X | X | X | X | |||
1 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
PTC Windchill Connector
| PTC Windchill | ||||||
|---|---|---|---|---|---|---|
| Version | 12.0.2 | 12.1 | 13.0 | 13.0.2 | 13.1 | |
|
Eplan Electric P81, Eplan Fluid1, Eplan Pro Panel, Eplan Preplaning, Eplan Harness proD |
2026 | X | X | X | X | |
| 2025 | X | X | X | X | X | |
| 2024 | X | X | X | X | X | |
| 2023 | X | X | X | X | ||
1 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
PRO.FILE by Revalize Connector
| PRO.FILE by Revalize | ||||
|---|---|---|---|---|
| Version | 8.6 (minimum SP24) | 8.7 (minimum SP17) | 10.4 (minimum SP14) | |
|
Eplan Electric P82, Eplan Fluid2, Eplan Pro Panel, Eplan Preplaning, Eplan Harness proD |
2026 | X1 | X | |
| 2025 | X1 | X1 | X | |
| 2024 | X1 | X1 | X | |
| 2023 | X1 | X1 | X | |
1 Not applicable to Eplan Harness proD.
2 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.
Dassault Systèmes 3DExperience Connector
| DS 3DExperience | ||||
|---|---|---|---|---|
| Version | 2023x FD021 | 2024x FD00 | 2025x FD00 | |
|
Eplan Electric P82, Eplan Fluid2, Eplan Pro Panel, Eplan Preplaning |
2026 | X | X | |
| 2025 | X | X | X | |
| 2024 | X | X | X | |
| 2023 | X | X | X | |
1 Only applicable for Dassault 3DExperience on-premises
2 As of Version 2026 Eplan Fluid is part of Eplan Electric P8.