Parameters |
Description |
TYPE |
Type of task to perform the action: |
|
Project name with complete file path (optional). |
|
Specifies whether the current selection in the user interface is to be taken into account during numbering (optional, 0 = No, 1 = Yes). |
|
Numbering scheme (optional). |
|
Start value for the numbering (optional). |
|
Increment; value by which the counter is increased (optional). Default value: |
|
Renumbering of the devices that are marked with a flag "?" (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Also number those controlled by PLC (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Allow change in sorting (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Fill gaps (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Group (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Structure-oriented numbering (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Keep interval (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Keep text (optional, 0 = No, 1 = Yes). |
|
Corresponds to the Subpages setting (optional). |
|
Corresponds to the setting Prefix (optional, 0 = No, 1 = Yes). |
|
Corresponds to the setting Suffix (optional, 0 = No, 1 = Yes). |
|
Corresponds to the Sequence setting (optional). |
|
Corresponds to the Extent setting (optional). |
|
Corresponds to the N terminals / pins setting (optional). |
|
Corresponds to the PE terminals / pins setting (optional). |
|
Corresponds to the SH terminals / pins setting (optional). |
|
Corresponds to the Multiple terminals setting (optional). |
|
Corresponds to the Terminals with alphabetical characters setting (optional). |
|
Corresponds to the setting Keep existing cable DTs (optional, 0 = No, 1 = Yes). |
|
Start value for the numbering of connection groups (optional). |
|
Increment for the numbering of connection groups; value by which the counter is increased (optional). Default value: |
|
Connection group (optional). Only available if the TYPE parameter has the following value: |
|
Overwrite mode (optional). |
|
Corresponds to the Avoid identical designations setting (optional). |
|
Corresponds to the Visibility setting (optional). |
|
Corresponds to the Mark as 'manually set' setting (optional). Only available if the TYPE parameter has the following value: |
Number devices:
Renumber /TYPE:DEVICES /STARTVALUE:1 /STEPVALUE:1 /USESELECTION:0 /OMITNUMERATEDBYPLC:0 /NUMERATECABLES:0 /IDENTIFIER:X* /CONFIGSCHEME:"Kennbuchstabe Zähler" /POSTNUMERATE:0
Number pages:
Renumber /TYPE:PAGES /STRUCTUREORIENTED:0 /STARTVALUE:3 /STEPVALUE:10 /KEEPINTERVAL:1 /KEEPTEXT:0 /SUBPAGES:1 /USESELECTION:0
Number connections:
Renumber /TYPE:CONNECTIONS /CONFIGSCHEME: Potenzialorientiert /STARTVALUE_1:13 /STEPVALUE_1:3 /OVERWRITE:0 /AVOIDIDENTICALDESIGNATIONS:0 /VISIBILITY:1 /MARKASMANUAL:1 /USESELECTION:0 /GROUP_1:1