Message number
|
Message text
|
P501001
|
The macro <x> <y> entered at the part does not exist
|
P501002
|
The image file <x> entered at the part does not exist
|
P501003
|
The document <x> entered at the part does not exist
|
P501004
|
The function definition <x> entered at the part is obsolete
|
P501005
|
The layer <u> assigned to the macro <x> (<y> / <z>) is user-defined
|
P501006
|
The elements of the macro <x> (<y> / <z>) are not grouped
|
P501007
|
The height, width and / or depth is not specified at the part: Height = <x>, Width = <y>, Depth = <z>
|
P501008
|
The connection point pattern <x> entered at the part does not exist
|
P501009
|
The drilling pattern <x> entered at the part does not exist
|
P501010
|
The part <x>, variant <y>, does not exist at the assembly / module
|
P501011
|
Part property 'Type number' is empty
|
P501012
|
Part property 'Order number' is empty
|
P501013
|
Part property 'Designation 1' is empty
|
P501014
|
Part property 'Generic product group' is undefined
|
P501015
|
Part property 'Product group' is undefined
|
P501016
|
Part property 'Product subgroup' is undefined
|
P501017
|
No trade is selected at the part
|
P501018
|
The dimensions 'Width' and 'Height' stored at the part do not agree with the dimensions of the macro <x> (<y> / <z>) (tolerance <u> percent)
|
P501019
|
Symbol library <x> was not found in the project (<y>)
|
P501020
|
The accessory part <x>, variant <y>, <z>, entered at the part does not exist
|
P501021
|
Part property 'ERP number' is not unique
|
P501022
|
The connection dimensions of the function templates do not match the connection dimensions at the connection point pattern
|
P501023
|
The function templates of the assembly / module <x>, variant <y> are not up-to-date
|
P501024
|
Part number with blank at beginning or end
|
P501025
|
Part properties 'PLC type designation' or 'Device description: File name' are empty
|
P501026
|
The bus port '<x>' entered in the function templates of the part was not found in single-line representation in the macro '<y>'
|
P501027
|
Connection point data at the bus port are filled
|
P501028
|
'Plug designation' property at the bus port is empty
|
P501029
|
The part <z>, variant <u>, entered at the module <x>, variant <y>, has neither a DT nor a DT ID
|
P501030
|
The drilling pattern <x> entered at the part is incomplete. The outline '<y>' does not exist
|
P501031
|
The general function definition '<x>' entered at the part should not be used at the part
|
P501032
|
The channel designation entered in the function templates of the part is invalid
|
P501033
|
The identifying connection point information of the function templates does not match the connection point data at the connection point pattern
|
P501034
|
The PLC device identification is not unique
|
P501035
|
The user-defined property '<x>' with the value '<y>' is not defined in the dialog 'Configure properties'.
|
P501036
|
The part property 'ERP number' is not identical at all variants of the part.
|
See also
Check Run Messages: Overview