This functionality is only available for certain module packages. Info / Copyright
Message number
Message text
P028001
Structure segment occurring multiple times
P028002
Planning object occurring multiple times
P028003
Structure identifier occurring multiple times in structure segments (<x> = Structure identifier)
P028004
The planning object has several parts with potential main functions
P028005
The value sets at the segment or at the segment template do not match the macro specified
P028006
The full DT of the function does not match the pre-planning
P028007
Differing parts or number / quantity of parts between main function and associated planning object
P028008
The planning object has a function template for which there is no function
P028009
Not all functions / representation types of the device reference the same planning object
P028010
The data of the PLC connection point differ from the data of the PLC address in the pre-planning
P028011
PLC address at the planning object without placed PLC connection point
P028012
There is more than one graphical placement for the structure segment
P028013
There is more than one graphical placement for the planning object in the '<x>' representation type
P028014
The planning object has parts with templates and at least one additional template of its own
P028015
Segment with a '<x>' segment definition that is not to be used anymore
P028016
Segment is subordinated to a '<x>' segment definition that is not permitted
P028017
Identifying designation at PCT loops occurring multiple times
P028018
Difference between segment and segment template (property '<x>')
P028019
The macro at the planning object does not correspond to the placed macro
P028020
Macro at the planning object is not placed in the representation type 'multi-line'
P028021
Macro at the planning object is not placed in the representation type 'single-line'
P028022
Planning object is not placed in the representation type 'Pre-planning'
P028023
PCT loop or PCT loop function is not placed in representation type 'P&I diagram'
P028024
The pre-planning assigned to the object has been deleted
P028025
Macro at the planning object is placed several times in a representation type
P028026
The source and / or target segment is missing at the piping or cable planning object
P028027
Source or target '<x>' of the piping definition does not match the source or target segment '<y>' in the piping planning object
P028028
The substance '<x>' entered does not exist as a template in the project
P028029
The pipe class '<x>' entered does not exist as a template in the project
P028030
The pipe class entered at the piping definition point does not correspond to the pipe class '<x>' of the linked piping planning object
P028031
The part '<x>' entered at the segment is not contained in the pipe class '<y>'
P028032
The subordinate segments do not match the subordinate segment templates
P028033
The segment has no assigned function
P028034
The segment has no assigned main function
P028035
The segment has no assigned function of the representation type 'Multi-line'
P028036
The segment has no assigned function of the representation type 'P&I diagram'
P028037
The segment has no assigned function of the representation type 'Pair cross-reference'
See also
Check Run Messages: Overview