Message number
Message text
P004003
The property '<y>' which belongs to the specified configuration value '<x>' does not have a number
P004004
Missing bus port on overview
P004005
Missing PLC connection point on overview
P004006
PLC box without conn. point
P004007
Rack '<x>' is mounted on itself
P004009
Slot (module) '<x>' of a rack '<y>' assigned several times
P004010
Rack '<x>' is unknown
P004013
Rack '<x>': Ring connection
P004016
Rack '<x>' is not unique
P004018
No actuator at output
P004019
No sensor at input
P004020
More than one I/O connection point with the same representation type at a channel
P004021
Address has been assigned more than once within a CPU
P004022
Connection point description assigned more than once at a channel (address) of a PLC card
P004023
Address is missing
P004024
Connection point description is missing
P004025
Slot / module is missing
P004027
Missing or incorrect channel designation
P004028
Conflict between PLC input / output and related supply connection point within the defined channel
P004029
Object marked for deletion
P004030
Missing symbolic address (automatic)
P004031
Symbolic address has been assigned more than once within a CPU
P004035
Bus ID '<x>' within a logical network '<y>' assigned several times (bus port in the bus system: <z>')
P004036
Unknown logical network '<x>' (bus port in the bus system: <y>')
P004037
Missing bus ID (bus port '<x>' in the bus system: '<y>')
P004038
A data transfer rate is defined for the bus slave '<x>' at the bus port in the bus system '<y>'
P004039
Connection between different bus systems ('<x>', '<y>')
P004040
Contradictory specifications at the associated bus port were found for the bus port at '<x>'
P004045
Communication unit at the PLC box: '<x>'
P004046
A conflict occurred during the adoption of the PLC data for '<x>'
P004050
Connection from '<x>' to '<y>' missing
P004051
Connection missing! <x> is not connected to the physical network '<y>'
P004052
Connection to the wrong physical network! '<x>' has to be connected to the physical network '<y>'
P004053
Too many differences were found between the network structure in the import file and in the project! Please check all network structures
P004054
Connection only in project! The connection to '<x>' only exists in the project
P004055
More than one rack was found during importing. Ensure that you use the right hardware for connecting
P004056
Part not found: PLC type designation '<x>' or device description file '<y>' / Index '<z>'! Import of '<u>' may be faulty
P004057
Several parts with the same or suitable device identification '<x>' found. A different part possibly has to be assigned to the function '<y>'
P004058
Accessory part '<x>' at function '<y>' is only available in the project
P004070
No matching bus port (output) at the predecessor address '<y>' was found for the bus port (input) at '<x>'
P004071
Bus interface '<x>': 'Bus interface: Main bus port' property activated more than once or not activated
P004072
Bus ID '<x>' of a physical network '<y>' assigned several times
P004073
'Function text (automatic)' has been assigned more than once (in the language '<x>') within a CPU
P004080
Missing configuration project
P004081
Missing station ID
P004082
Configuration project '<x>' does not contain a CPU
P004083
The CPU class '<x>' entered at the PLC box does not exist in the project
P004084
The MasterSystemID is faulty
P004085
Missing data type
P004086
Missing PLC type designation or device description file
P004087
Missing start address
P004088
The PLC card name '<x>' is already being used at a rack or a CPU
P004089
PLC card name '<x>' assigned several times within a rack
P004090
PLC station type in the project and at the part differ
P004091
Missing plug designation
P004092
Missing bus interface name
P004093
The PLC connection point references an invalid subdevice with the property 'PLC subdevice: Index'
P004094
CPU name '<x>' assigned several times
P004095
Missing safety address
P004096
Multiple assignment of safety address: Target '<x>'
P004097
More than one I/O connection point at a channel within a type of signal in a subdevice
P004098
Wrong DT format
P004099
PLC card with the device identification '<x>' is not placed on a head station
P004100
The CPU is not assigned to a slot / module and / or a rack
P004101
The rack '<x>' is not connected by a bus extension cable with all other racks of the station '<y>'
P004102
The bus port in the station '<x>' is connected by a bus extension cable with the bus port in the station '<y>'
P004103
Bus slave and bus master differ in the property 'Physical network: Name'
P004104
Bus ports of the physical network '<x>' are not connected to each other
P004106
PLC address '<x>' is not located in the address range of the respective PLC card
P004107
Address range of the PLC card '<x>' overlaps with the address range of the PLC card '<y>'
P004108
The user-defined property '<x>' at the PLC card with the device identification '<y>' is unknown
P004109
Difference between single-line and multi-line network structures
P004110
Physical network without name
P004111
Connection between bus ports with different property 'Physical network: Name' ('<x>', '<y>')
P004112
Incorrect data type '<x>' or incorrect data length of the channel
P004113
Symbolic address (automatic) contains a blank, a tabulator or a line break
P004114
PLC address '<x>' is not located in the address range of the subdevice '<y>' belonging to the PLC card
P004115
Address range of the subdevice '<x>' overlaps with the address range of the subdevice '<y>' of the PLC card '<z>'
P004116
Address range of the subdevice '<x>' is located partially or completely outside the address range of the PLC card '<y>'
P004117
Incorrect DT during AutomationML AR APC import
P004118
Missing CPU name at a PLC card in the configuration project '<x>' with multiple CPUs
P004119
Multiple assignment of safety address: Source '<x>'
P004120
'Symbolic address: UDT (data type)' is empty even though 'Symbolic address: UDT (name)' exists
P004121
'Symbolic address: UDT (data type)' is not unique
P004122
The logical network '<x>' is connected via different bus systems
P004200
Siemens: Incorrect PLC card assignment: <x>
P004201
Siemens: Incorrect PLC station type assignment: <x>
P004202
Siemens: Incorrect bus port: <x>
P004203
Siemens: PLC card with the PLC station type '<x>' is not a valid rack
See also